Honeywell 113228/U Original Industrial Spare UV Compatible
113228/UHoneywell 113228/U original UV flame sensor for RM7800 & R7847 burner management systems. OEM spare, industrial replacement, 12-month warranty, fast dispatch.
Request availability, condition, lead time and export shipping details for 2108B2001N.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Honeywell 2108B2001N is an original fixed-point infrared gas detector from the Searchpoint Optima Plus series, engineered by Honeywell Analytics for continuous combustible and toxic gas monitoring in demanding industrial environments. Whether you are managing a scheduled shutdown, responding to an unplanned fault, or building a strategic spare parts inventory, the 2108B2001N delivers the reliability and drop-in compatibility that maintenance engineers depend on to keep production lines running safely and without interruption.
In petrochemical plants, offshore platforms, LNG terminals, water treatment facilities, and manufacturing sites worldwide, the Searchpoint Optima Plus platform has become a benchmark for fixed-point gas detection. Sourcing an original OEM replacement unit — rather than an aftermarket substitute — ensures that your safety system maintains its certified performance envelope, passes site audits, and continues to meet SIL-rated functional safety requirements without recertification delays.
| Part Number | 2108B2001N |
| Brand / Manufacturer | Honeywell Analytics |
| Series | Searchpoint Optima Plus |
| Detection Technology | Non-Dispersive Infrared (NDIR) |
| Detection Target | Combustible gases (hydrocarbons); configurable for specific gas types |
| Output Signal | 4–20 mA analogue + HART digital communication |
| Supply Voltage | 18–32 V DC |
| Power Consumption | ≤ 3.5 W (steady state) |
| Ingress Protection | IP66 / IP67 |
| Explosion Protection | ATEX / IECEx certified; Ex d IIC T6 Gb |
| Operating Temperature | −40 °C to +65 °C |
| Humidity Range | 0–99% RH (non-condensing) |
| Mounting | Standard 2-inch NPT / BSP pipe mount; compatible with Optima Plus junction box |
| Country of Origin | United Kingdom |
| Compatibility | Direct replacement for all Searchpoint Optima Plus field units; backward compatible with Optima (standard) controller infrastructure |
| Functional Safety | SIL 2 capable (as per IEC 61508) |
| Warranty | 12 Months — every unit tested and verified before dispatch |
A fixed-point gas detector is only as reliable as the broader safety loop it belongs to. When a 2108B2001N is flagged for replacement during a planned turnaround or an emergency callout, experienced maintenance teams treat the event as an opportunity to audit the entire gas detection circuit — not just the sensor head.
Begin with the Honeywell Optima Plus junction box and field wiring harness. Corroded terminals or degraded cable glands are a leading cause of spurious faults and signal drift in outdoor installations. Inspect and, where necessary, replace the 3-core armoured instrument cable running from the detector to the control panel — particularly in installations older than five years or those exposed to UV, chemical wash-down, or mechanical vibration.
At the control panel end, verify the condition of the Honeywell Searchpoint controller or compatible gas detection controller (such as the Honeywell Touchpoint Plus or Touchpoint Pro). These controllers receive the 4–20 mA / HART signal from the 2108B2001N and trigger alarms, shutdowns, or ventilation interlocks. A controller with degraded input cards or failing power supply modules will misread even a perfectly functioning sensor. Inspect the controller power supply module and confirm output voltage stability under load.
For sites running multi-channel detection systems, the analogue input modules within the safety PLC or DCS that process gas detector signals should be included in the inspection scope. Honeywell Safety Manager, Triconex, or equivalent SIL-rated safety system I/O modules handling 4–20 mA inputs are worth bench-testing during any planned outage where a detector replacement is already scheduled.
Do not overlook the relay output modules downstream of the controller. These drive audible alarms, beacon lights, solenoid valves, and emergency ventilation fans. A relay with worn contacts may fail to actuate at the critical moment — defeating the purpose of a fully functional detector. Pairing a detector replacement with a relay module inspection is a low-cost, high-value maintenance step.
For installations in classified hazardous areas, also review the Zener barrier or galvanic isolator modules in the associated apparatus cabinet. These protect intrinsically safe circuits and can degrade silently over time. Replacing an aged isolator alongside the 2108B2001N ensures the entire intrinsically safe loop is restored to its certified state.
Finally, if your site uses a portable gas detector (such as a Honeywell BW Solo or GasAlert Micro Clip) for bump-testing and functional verification of fixed-point units, confirm that the portable unit’s sensors are within their calibration interval. Accurate bump-test results depend on a calibrated reference instrument — a detail often overlooked during reactive maintenance events.
Stocking the 2108B2001N alongside these complementary components — junction box hardware, instrument cable, relay modules, isolator barriers, and controller spares — transforms a reactive repair into a structured, audit-ready maintenance programme that minimises future downtime risk.
The 2108B2001N is the current-generation replacement for earlier Honeywell Searchpoint Optima (non-Plus) field units. Sites still operating legacy Optima detectors can upgrade to the Optima Plus platform without replacing the existing controller infrastructure, provided the controller firmware supports the enhanced HART diagnostics of the Plus series. This makes the 2108B2001N one of the most cost-effective system modernisation options available for ageing gas detection installations.
For maintenance planners managing large multi-point installations, the NDIR technology in the Optima Plus eliminates the consumable catalytic bead element found in older pellistor-based detectors. This removes a recurring replacement cost and reduces the frequency of scheduled sensor swaps — lowering total cost of ownership over a 10-year asset lifecycle.
When a detector fails during production, every hour of downtime carries a measurable cost. Holding a 2108B2001N as a certified on-site spare eliminates the lead time risk associated with emergency procurement. Our stock is pre-tested, serialised, and dispatched within 24–48 hours of order confirmation, with full traceability documentation included to satisfy site QA and HSE audit requirements.
For EPC contractors and system integrators specifying new installations or retrofits, the 2108B2001N’s standard 2-inch pipe mount and universal 4–20 mA / HART output make it compatible with virtually all major DCS and safety PLC platforms — including Honeywell Experion PKS, Emerson DeltaV, ABB System 800xA, and Siemens SIMATIC PCS 7 — without requiring signal conditioning adapters.
Q1: Is the 2108B2001N a direct drop-in replacement for the original Searchpoint Optima (non-Plus)?
Yes. The Optima Plus series maintains mechanical and electrical backward compatibility with the standard Optima mounting arrangement and wiring. The 4–20 mA output is fully compatible with existing controller inputs. The additional HART diagnostics of the Plus series are available if your controller supports HART; if not, the unit operates transparently as a standard analogue detector.
Q2: What pre-shipment testing is performed on each unit?
Every 2108B2001N is powered-on, signal-verified, and inspected for physical integrity before dispatch. Units are shipped with original manufacturer packaging and, where available, factory test documentation. A 12-month warranty covers all units against manufacturing defects from the date of delivery.
Q3: How should I manage spare parts inventory for a multi-point gas detection system?
Industry best practice for critical safety instrumentation is to hold a minimum of one spare detector per ten installed field units, with a floor of one spare regardless of installation size. For remote or offshore sites where resupply lead times exceed 72 hours, a ratio of one spare per five units is recommended. Pairing detector spares with junction box hardware and instrument cable reels ensures a complete field replacement kit is always available.
Q4: Can compatibility be verified before purchase for a specific site installation?
Yes. Provide your existing detector part number, controller model, and DCS/safety PLC platform details to our technical team at [email protected]. We will confirm compatibility and, where applicable, advise on any firmware or configuration considerations before the order is placed.
Click Quote This Model and the Part Number field will auto-fill with 2108B2001N.