1788HP-EN2PA

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

BrandHIPROM
Part Number1788HP-EN2PA
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesOther series
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

HIPROM 1788HP-EN2PA Ruggedized PROFIBUS PA/DP Linking Module: Industrial Resilience for Harsh Environments

The HIPROM 1788HP-EN2PA is a high-performance PROFIBUS PA/DP linking device engineered for continuous, fault-tolerant operation in the most demanding industrial environments. As part of HIPROM’s proven HP Series communication platform, this module bridges PROFIBUS DP master controllers with PROFIBUS PA field instruments — delivering deterministic, low-latency data exchange even under conditions of extreme temperature fluctuation, high humidity, pervasive dust, mechanical vibration, and intense electromagnetic interference (EMI).

Designed for mission-critical process automation, the 1788HP-EN2PA is the backbone communication link that keeps your PLC, DCS, and field instrumentation in continuous synchronization. Whether deployed in a hazardous-area control cabinet, a remote field junction box, or a centralized process control room, this module maintains signal integrity and protocol compliance without compromise.

Rugged Specifications Table

Parameter Specification
Part Number / SKU 1788HP-EN2PA
Brand / Series HIPROM / HP Series
Module Type PROFIBUS PA/DP Linking Device (Communication Module)
Protocol PROFIBUS PA (IEC 61158-2) ↔ PROFIBUS DP (RS-485)
PA Ports 2 × PROFIBUS PA segments
DP Interface PROFIBUS DP-V1 compliant
Operating Temperature -20°C to +70°C (industrial extended range)
Storage Temperature -40°C to +85°C
Relative Humidity 5% to 95% RH, non-condensing
Protection Rating IP20 (module); suitable for IP54+ enclosure installation
EMC / EMI Immunity EN 61000-4 series; IEC 61326-1 compliant
Vibration Resistance IEC 60068-2-6 (sinusoidal); suitable for heavy machinery environments
Power Supply 24 V DC (SELV), redundant power input supported
Weight 1,470 g
Mounting DIN rail / panel mount
Certifications CE, ATEX-compatible installation (zone 2 with appropriate enclosure)
Compatible Systems Siemens SIMATIC S7, ABB System 800xA, Emerson DeltaV, Yokogawa CENTUM
Country of Origin China
Warranty 12 Months — covers manufacturing defects and functional failure under normal operating conditions
Stock Status In Stock — tested, inspected, ready to ship

Comprehensive Protection Solutions

In modern process automation architectures, the HIPROM 1788HP-EN2PA does not operate in isolation — it is the critical communication spine that connects and protects an entire ecosystem of field devices and control hardware. When integrated into a Siemens SIMATIC S7-400 or S7-300 PLC system, the 1788HP-EN2PA enables the DP master to poll PROFIBUS PA instruments — including pressure transmitters, flow meters, and level sensors — at deterministic cycle times, even when the control cabinet is exposed to high-frequency vibration from adjacent compressors or pumps.

In DCS environments built on platforms such as the ABB System 800xA or Emerson DeltaV, the module serves as the segment coupler that isolates the high-speed DP backbone from the intrinsically safe PA field segment. This isolation is essential when the PA segment runs through hazardous zones where explosive atmospheres may be present. Paired with a HIPROM HP Series redundant power supply module and a HIPROM segment terminator, the 1788HP-EN2PA ensures that a single power fault or cable break does not cascade into a full segment failure.

For I/O-intensive applications, the module works in concert with remote I/O stations and distributed I/O modules — such as Siemens ET 200M or ET 200S racks — allowing field signals from thermocouples, RTDs, and discrete sensors to be aggregated and transmitted over the PROFIBUS DP backbone without signal degradation. In variable-speed drive applications, the 1788HP-EN2PA maintains communication integrity between the PLC master and PROFIBUS-enabled variable frequency drives (VFDs), ensuring that speed references and fault diagnostics are exchanged reliably even in environments with high conducted EMI from motor switching transients.

The module is also routinely deployed alongside PROFIBUS PA safety barriers, galvanic isolators, and surge protection devices at field junction boxes, providing a complete protection chain from the control room to the last field instrument. When combined with a HIPROM HP-EN2 Ethernet/PROFIBUS gateway or a PROFIBUS DP/Modbus RTU converter, the 1788HP-EN2PA enables legacy PA field devices to be integrated into modern Industrial Ethernet or SCADA architectures without requiring full instrument replacement — a significant cost advantage in brownfield upgrade projects.

Application in Critical Infrastructure

The HIPROM 1788HP-EN2PA is field-proven across the most demanding sectors of critical infrastructure, where communication failure is not an option:

Oil & Gas: In upstream wellhead automation and midstream pipeline SCADA systems, the 1788HP-EN2PA links PROFIBUS PA pressure and flow transmitters to the DP master controller in explosion-proof control panels. Its wide operating temperature range and vibration tolerance make it suitable for offshore platform installations and onshore compressor stations where ambient conditions are extreme and maintenance access is infrequent.

Mining & Mineral Processing: In underground mining operations and surface ore processing plants, the module withstands the high dust concentrations, mechanical shock, and ground-loop interference that routinely degrade standard communication hardware. It maintains reliable data exchange between the PLC and PA-instrumented slurry pumps, conveyor drives, and flotation cell level controls — keeping production lines running continuously through shift changes and equipment cycling.

Power Generation & Utilities: In coal-fired, gas turbine, and hydroelectric power plants, the 1788HP-EN2PA supports the PROFIBUS PA instrumentation networks that monitor boiler pressure, turbine speed, and cooling water flow. Its EMI immunity is critical in switchgear rooms and generator halls where high-voltage switching events generate intense electromagnetic transients that can corrupt data on less robust communication hardware.

Water & Wastewater Treatment: Municipal and industrial water treatment facilities rely on the 1788HP-EN2PA to maintain continuous communication between SCADA systems and PA-instrumented dosing pumps, pH analyzers, and flow control valves. The module’s humidity tolerance and corrosion-resistant design make it well-suited for the wet, chemically aggressive environments typical of treatment plant control rooms.

Metallurgy & Heavy Industry: In steel mills, aluminum smelters, and foundries, the 1788HP-EN2PA operates reliably in the presence of radiated heat, inductive loads from arc furnaces, and the mechanical vibration of rolling mills. It provides the stable PROFIBUS PA communication link that keeps temperature, pressure, and flow instrumentation synchronized with the plant DCS — enabling precise process control and reducing the risk of costly unplanned shutdowns.

Security & Quality FAQ

Q1: What does the 12-month warranty cover, and how is it enforced?
Every HIPROM 1788HP-EN2PA unit shipped by TOPNLMS carries a 12-month warranty covering manufacturing defects and functional failure under normal operating conditions. If a unit fails within the warranty period, we provide a replacement or full refund after fault verification. Warranty claims are processed directly through our technical team at [email protected] — no third-party RMA process required.

Q2: How is each unit tested before shipment?
All units undergo a multi-point functional inspection prior to dispatch: power-on verification, PROFIBUS DP/PA protocol handshake test, port continuity check, and visual inspection for physical damage. Units that do not pass all test criteria are quarantined and not shipped. A test report is available upon request for critical infrastructure procurement.

Q3: Is the 1788HP-EN2PA compatible with my existing PLC or DCS platform?
The 1788HP-EN2PA is a standard PROFIBUS DP-V1 / PA device and is compatible with any DP master that conforms to the IEC 61158 standard — including Siemens SIMATIC S7 series, ABB System 800xA, Emerson DeltaV, Yokogawa CENTUM VP, and Honeywell Experion PKS. GSD file support ensures seamless integration into your existing engineering tool (STEP 7, TIA Portal, or equivalent). Contact our technical team if you require compatibility confirmation for a specific system revision.

Q4: Can TOPNLMS guarantee long-term supply and replacement support for this module?
Yes. TOPNLMS maintains dedicated stock of HIPROM HP Series modules, including the 1788HP-EN2PA, to support both planned maintenance schedules and emergency spare-part requirements. We understand that industrial plants cannot afford extended lead times for critical communication hardware. Our standard order processing time is 1–3 business days, with express shipping options available for urgent requirements. For large-volume or long-term supply agreements, contact us directly to discuss framework pricing and reserved stock arrangements.