GE NP 104X905BA603 Ruggedized Operator Input Module for Harsh Environments
NP 104X905BA603GE NP 104X905BA603 ruggedized membrane keypad panel for Mark IV/V turbine control. EMI-resistant, industrial-grade. In stock, tested, 12-month warranty.
Request availability, condition, lead time and export shipping details for IC697MDL350.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The GE IC697MDL350 is a 32-point, 120VAC discrete output module designed for the GE Series 90-70 PLC platform — one of the most widely deployed programmable logic controller architectures in North American industrial automation. As the Series 90-70 product line reaches end-of-life and spare parts become increasingly scarce, facilities running legacy control systems face mounting pressure to source verified replacement modules that maintain full backward compatibility with existing field wiring, rack infrastructure, and ladder logic programs.
This listing provides a tested, ready-to-ship IC697MDL350 replacement module sourced to support direct drop-in installation. Whether your plant is executing a phased migration from an aging Series 90-70 rack to a newer GE PACSystems RX7i or RX3i architecture, or simply maintaining uptime on a production line that cannot afford extended downtime, this module is stocked and inspected to meet your operational requirements.
| Parameter | IC697MDL350 (This Module) | Typical Legacy / Replaced Module |
|---|---|---|
| Platform | GE Series 90-70 | GE Series 90-70 (same rack) |
| Output Type | Discrete, 120VAC | Discrete, 120VAC (IC697MDL340 / IC697MDL341) |
| Point Count | 32 points | 16-point variants (IC697MDL340) |
| Rack Compatibility | IC697CHS750 / IC697CHS782 / IC697CHS790 | Same Series 90-70 rack backplane |
| Field Wiring | Standard TB connector, 120VAC field devices | Direct re-use of existing terminal block wiring |
| Communication | Backplane I/O bus (Series 90-70 native) | Same backplane protocol — no program changes required |
| CPU Compatibility | IC697CPU772 / IC697CPU781 / IC697CPU782 | All Series 90-70 CPUs |
| Installation Space | Single slot, standard Series 90-70 form factor | Same physical slot — no panel modification needed |
| Programming Tool | Proficy Machine Edition (ME) / Logicmaster 90 | Existing I/O configuration reusable |
| Warranty | 12-Month Warranty — covered from date of shipment | |
Replacing the IC697MDL350 is rarely an isolated action. In most Series 90-70 retrofit projects, the output module swap is part of a broader system modernization effort that touches multiple components within the same rack or control cabinet. During the migration process, engineers commonly address the IC697PWR710 or IC697PWR711 power supply module to ensure adequate current capacity for the updated I/O configuration. If the rack is being partially upgraded, the IC697CHS750 nine-slot rack or IC697CHS782 twelve-slot rack may be retained as-is, allowing the IC697MDL350 to slot directly into the vacated position without any mechanical modification.
On the input side, discrete input modules such as the IC697MDL653 (32-point 24VDC input) or IC697MDL671 (32-point 120VAC input) are frequently replaced in the same maintenance window, consolidating downtime and reducing the number of separate service interventions. For facilities transitioning toward a PACSystems RX7i platform, the IC698CHS009 rack and IC698CPE020 controller may be introduced alongside the legacy Series 90-70 hardware during a phased cutover, with the IC697MDL350 continuing to serve non-critical output circuits during the transition period.
Communication infrastructure is another key consideration. Many Series 90-70 installations rely on the IC697CMM742 Ethernet module or IC697CMM711 serial communications module for SCADA connectivity. These modules remain in service during an output module replacement and do not require reconfiguration. If the site uses Genius Bus I/O, the IC697BEM711 bus controller module coordinates field device communication independently of the discrete output modules, further simplifying the swap procedure.
For sites requiring signal conditioning between the PLC output and field devices operating at non-standard voltages, DIN-rail-mounted signal isolators are commonly installed in the same control cabinet without affecting the IC697MDL350’s wiring or slot assignment.
Q: Can I reuse existing field wiring when replacing the IC697MDL350?
A: Yes. The IC697MDL350 uses the same terminal block connector and 120VAC output configuration as other Series 90-70 discrete output modules. Existing field wiring to contactors, solenoids, and motor starters can be reconnected directly without modification.
Q: Do I need to modify my ladder logic program after installing this module?
A: No program changes are required if the replacement module occupies the same rack slot and the I/O address mapping remains unchanged in Proficy Machine Edition or Logicmaster 90. The CPU recognizes the module by slot position and output type.
Q: Is this module compatible with all Series 90-70 CPUs?
A: Yes. The IC697MDL350 is compatible with all Series 90-70 CPU modules, including the IC697CPU772, IC697CPU781, and IC697CPU782, across all standard rack configurations.
Q: What is the physical installation procedure?
A: Power down the rack, remove the failed module, insert the IC697MDL350 into the same slot, reconnect the terminal block, and restore power. No tools beyond a standard screwdriver are required. Commissioning time is typically under 30 minutes for a direct replacement.
Q: Can this module be used during a phased migration to PACSystems RX7i?
A: Yes. The IC697MDL350 can continue operating in the existing Series 90-70 rack while new PACSystems hardware is commissioned in parallel, supporting a staged cutover that minimizes production disruption.
Q: What communication protocols does this module support?
A: The IC697MDL350 communicates via the Series 90-70 backplane I/O bus. It does not require Ethernet, Profibus, or Modbus configuration — all communication is handled natively by the rack backplane and CPU.
Every IC697MDL350 unit shipped from TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each module undergoes functional verification including output channel continuity checks and backplane connector inspection. Units that do not meet our quality threshold are not listed for sale.
In the event of a confirmed defect within the warranty period, TOPNLMS provides replacement support with priority processing. Our after-sales response target is within one business day for warranty claims submitted via email. Replacement units are dispatched from our Xiamen warehouse, with international express shipping available to minimize your system downtime.
For procurement teams requiring documentation, we can provide test records, shipment photos, and packing lists upon request. Bulk orders for MRO inventory programs are accommodated with lead-time confirmation prior to order placement.
Contact our technical sales team to confirm compatibility with your specific rack configuration, CPU revision, or system architecture before ordering.
Click Quote This Model and the Part Number field will auto-fill with IC697MDL350.