GE IS230SNAIH4A IS200STAIH2ACB Mark VI Replacement
IS230SNAIH4A IS200STAIH2ACBGE IS230SNAIH4A IS200STAIH2ACB Mark VI turbine control board replacement. Compatible upgrade, fast shipping, 12-month warranty. Minimize downtime.
Request availability, condition, lead time and export shipping details for DS200SVAAG1A.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The GE DS200SVAAG1A (DS200SVAAG1ACB) is an original Voltage Attenuator Card engineered for the GE Mark VI Speedtronic turbine control system — one of the most widely deployed gas and steam turbine control platforms in power generation, oil & gas, and heavy industrial facilities worldwide. As aging Mark VI systems continue to operate well beyond their original design life, maintaining a reliable inventory of original spare cards like the DS200SVAAG1A is a cornerstone of any responsible preventive maintenance and asset longevity strategy.
This card performs critical signal conditioning and voltage attenuation functions within the Mark VI control cabinet, ensuring that high-voltage field signals are accurately scaled before being processed by the controller. A failed or degraded DS200SVAAG1A can result in erroneous turbine speed or voltage readings, triggering nuisance trips, unplanned shutdowns, or — in worst-case scenarios — undetected overvoltage conditions. Stocking a verified original replacement eliminates the diagnostic uncertainty that comes with counterfeit or refurbished alternatives.
| Part Number | DS200SVAAG1A / DS200SVAAG1ACB |
| Manufacturer | General Electric (GE) |
| Series | Mark VI Speedtronic Turbine Control |
| Card Type | Voltage Attenuator Card |
| Application | Gas Turbine / Steam Turbine Control Systems |
| Compatibility | GE Mark VI, Mark VIe Speedtronic Control Cabinets |
| Signal Function | High-voltage field signal attenuation and conditioning |
| Mounting | VME-style card cage, Mark VI I/O module rack |
| Operating Environment | Industrial control cabinet; 0–55°C ambient |
| Power Supply | Supplied via Mark VI backplane (28 VDC typical) |
| Condition | Original / New Surplus / Tested Refurbished (as specified) |
| Pre-shipment Testing | Full functional test performed before dispatch |
| Warranty | 12 Months from date of shipment |
| Lead Time | In stock — ships within 1–3 business days |
When a Mark VI Speedtronic system requires inspection or a DS200SVAAG1A replacement, experienced maintenance engineers know that a single card failure is rarely an isolated event. The voltage attenuation subsystem interacts closely with multiple other I/O and signal processing cards within the same control cabinet. A thorough inspection and proactive spare procurement plan should extend to the following components:
The DS200SDCCG1A (Speed Detector Card) works in tandem with the voltage attenuator to process turbine speed signals — if one shows signs of drift or failure, the other should be inspected simultaneously. Similarly, the DS200TCQAG1A (Turbine Control Card) relies on clean, attenuated input signals; any degradation upstream will manifest as control instability downstream. Maintenance teams should also verify the condition of the DS200IIBDG1A (I/O Interface Board), which routes field signals to and from the attenuator card and is subject to connector wear in high-vibration environments.
Power integrity is equally critical. The DS200PCCAG1A (Power Supply Card) and associated DS200DCFBG1A (DC/DC Converter Board) should be tested during any planned outage — voltage ripple or supply instability is a leading cause of premature card failure across the entire Mark VI rack. Fuse modules and terminal blocks within the cabinet should be inspected for corrosion or loose connections, particularly on systems operating in humid or coastal environments.
For facilities running redundant Mark VI configurations (TMR — Triple Modular Redundancy), it is best practice to replace the DS200SVAAG1A across all three control paths simultaneously to maintain voting symmetry. Stocking the DS200TCCAG1A (Turbine Control Card) and DS200EXPAG1A (Expansion I/O Card) as part of a rotating spare pool further reduces mean time to repair (MTTR) during unplanned outages. Finally, if the system communicates via IONET or Ethernet-based HMI, verifying the integrity of the DS200CPCAG1A (Communication Processor Card) ensures that operator visibility is maintained throughout the maintenance window.
The GE Mark VI Speedtronic platform has been in service since the 1990s, and many facilities are operating systems that are 15–25 years old. GE has progressively transitioned support toward the Mark VIe architecture, meaning that original Mark VI spare cards like the DS200SVAAG1A are no longer manufactured in volume — making verified original surplus stock increasingly valuable.
Sourcing the DS200SVAAG1A from a specialist industrial spare supplier eliminates the risk of counterfeit boards that may pass visual inspection but fail under load. Every unit shipped from TOPNLMS undergoes functional verification prior to dispatch, and is accompanied by documentation supporting traceability. For facilities managing a fleet of GE turbines, establishing a consignment or blanket-order arrangement for critical Mark VI cards reduces emergency procurement lead times from weeks to days — a decisive advantage when a turbine trip threatens production continuity.
For plants considering a phased migration to Mark VIe, maintaining a buffer stock of original Mark VI cards during the transition period is essential. The DS200SVAAG1A and its associated cards remain fully compatible with existing Mark VI cabinets and require no firmware changes or reconfiguration upon installation, enabling like-for-like replacement with minimal downtime.
Q1: Is the DS200SVAAG1A compatible with both Mark VI and Mark VIe systems?
The DS200SVAAG1A is designed for the GE Mark VI Speedtronic platform. Compatibility with Mark VIe depends on the specific cabinet configuration and I/O architecture. We recommend confirming your system’s rack and backplane revision before ordering. Our technical team can assist with compatibility verification.
Q2: What testing is performed before shipment?
Each DS200SVAAG1A unit undergoes a full functional test on a dedicated Mark VI test bench prior to dispatch. Test results are documented and available upon request. Units that do not meet original GE performance specifications are not shipped.
Q3: What does the 12-month warranty cover?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions from the date of shipment. It does not cover damage resulting from incorrect installation, overvoltage events beyond rated limits, or physical mishandling. Warranty claims are processed with priority turnaround to minimize your downtime.
Q4: How should I manage DS200SVAAG1A inventory for a multi-turbine facility?
For facilities operating three or more GE Mark VI-controlled turbines, we recommend maintaining a minimum of one DS200SVAAG1A per turbine train as a hot spare, with an additional unit in central stores. Pairing this with a scheduled annual inspection of all voltage attenuator and signal conditioning cards — and replacing any unit showing drift beyond ±2% of calibrated range — is a proven strategy for reducing unplanned outages.
Click Quote This Model and the Part Number field will auto-fill with DS200SVAAG1A.