GE IC220STR001 Ruggedized Motor Starter Module – Harsh Env
IC220STR001GE IC220STR001 ruggedized direct motor starter module for VersaMax Nano/Micro PLC. Reliable in harsh environments. 12-month warranty. Fast global shipping.
Request availability, condition, lead time and export shipping details for CT/VT8H UR8HH.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The General Electric CT/VT8H UR8HH is an original relay contact block engineered for the CT/VT Series control architecture. In industrial environments where uptime is non-negotiable, this component serves as a critical interface element within motor control centers, switchgear panels, and protection relay circuits. Whether you are managing a scheduled shutdown, responding to an unplanned fault, or building a proactive spare parts inventory, the CT/VT8H UR8HH delivers the dimensional accuracy, contact reliability, and electrical performance required to restore system integrity without modification or workaround.
Sourced directly from General Electric’s industrial automation supply chain, this relay contact block is manufactured to OEM specifications. It is not a compatible substitute or aftermarket approximation — it is the original component, tested and verified before dispatch, and backed by a 12-month warranty covering manufacturing defects and electrical performance under rated conditions.
| Parameter | Specification |
|---|---|
| Part Number | CT/VT8H UR8HH |
| Brand / OEM | General Electric (GE) |
| Series | CT/VT Series |
| Product Type | Relay Contact Block |
| Contact Configuration | 8-pole auxiliary contact block (NO/NC configurable per series standard) |
| Rated Voltage | Up to 690V AC / 250V DC (per CT/VT Series rating) |
| Rated Current | 10A AC-15 / 6A DC-13 (typical CT/VT Series rating) |
| Mounting Compatibility | CT/VT Series contactor and relay base frames |
| Installation Method | Snap-on / screw-mount per CT/VT Series standard |
| Operating Temperature | -25°C to +70°C |
| Protection Rating | IP20 (panel-mounted) |
| Compliance | IEC 60947-5-1 |
| Origin | United States (OEM) |
| Weight | Approx. 1,200 g (packaged) |
| Warranty | 12 Months — Manufacturing Defects & Electrical Performance |
| Application | Motor control centers, protection relay panels, switchgear, MCC cabinets |
| Maintenance Recommendation | Inspect contact surfaces every 6–12 months; replace at first sign of pitting or arc erosion |
When a CT/VT8H UR8HH relay contact block is flagged for replacement during a scheduled inspection or fault diagnosis, experienced maintenance engineers treat the event as an opportunity to audit the surrounding control circuit. Contact block degradation rarely occurs in isolation — it is typically accompanied by wear in adjacent components that share the same electrical duty cycle and thermal environment.
During the same maintenance window, it is advisable to inspect the CT/VT Series main contactor coil for insulation breakdown and coil resistance drift. The auxiliary contact modules mounted alongside the UR8HH block should be checked for contact bounce and resistance creep, particularly in high-cycle applications such as conveyor drives or pump stations. If the panel includes a GE THQL or THHQL series circuit breaker upstream of the contactor, verify trip calibration and terminal torque — loose connections at this stage are a common root cause of premature contact erosion downstream.
The control power transformer (CPT) feeding the relay coil circuit should be load-tested if the panel has been in service for more than five years. Voltage sag at the coil input is a leading cause of contact chatter and accelerated wear on blocks like the CT/VT8H UR8HH. Simultaneously, inspect the terminal blocks and DIN rail assemblies within the same cabinet section — loose or corroded terminations introduce resistance that compounds contact heating.
For facilities running GE Multilin or similar protection relay modules in the same cabinet, this is also an appropriate time to verify relay output contact ratings and confirm that the auxiliary contact block assignments in the relay logic still match the physical wiring. Any discrepancy between the relay configuration and the installed contact block type can cause nuisance trips or missed fault detection.
If the system includes a GE PLC I/O module — such as a Series 90 discrete input card — receiving status feedback from the CT/VT contactor, verify that the input signal levels remain within the module’s rated threshold after contact replacement. New contact blocks occasionally present slightly different contact resistance profiles during the initial run-in period, which can affect edge-sensitive digital inputs.
Facilities managing aging GE control systems should also consider stocking surge suppression modules for the contactor coil circuit, fuse holders and fuse links for the control voltage rail, and signal isolators if the feedback circuit crosses ground potential boundaries between panels. These components are frequently overlooked during spare parts planning but are among the first to fail when a contact block replacement disturbs the circuit’s steady-state conditions.
A complete preventive maintenance kit for a CT/VT Series motor control section typically includes the contact block, a spare contactor coil, one set of power contact tips, a CPT fuse set, and a terminal block inspection kit. Sourcing these as a coordinated spare package reduces the risk of a second unplanned outage within the same maintenance cycle.
The CT/VT8H UR8HH is a direct OEM replacement for aging or failed contact blocks within the General Electric CT/VT Series product family. Unlike generic aftermarket alternatives, this original component maintains full dimensional and electrical compatibility with existing CT/VT Series contactor frames — no adapter plates, no wiring modifications, and no recalibration of downstream protection settings.
For facilities that have been operating GE CT/VT Series contactors for ten or more years, the availability of original spare contact blocks is a significant factor in the total cost of system ownership. Replacing a worn contact block with an OEM-matched component extends the service life of the contactor frame itself, deferring the higher cost of a full contactor assembly replacement. This is particularly valuable in applications where the contactor is integrated into a custom-engineered MCC section that would require significant re-engineering to accommodate a different frame size or mounting standard.
In multi-panel facilities, standardizing on the CT/VT8H UR8HH as the approved spare for all CT/VT Series installations simplifies procurement, reduces inventory complexity, and ensures that maintenance technicians are working with a familiar component during high-pressure fault response situations. A single stocked unit can serve as a universal replacement across multiple panels, reducing the minimum viable spare parts inventory without increasing downtime risk.
For systems approaching end-of-life where the original GE CT/VT Series contactors are no longer in production, maintaining a buffer stock of original contact blocks is the most cost-effective strategy for extending system life until a full modernization project can be planned and budgeted. The 12-month warranty on each unit provides additional assurance that the replacement component will perform reliably through the transition period.
Q1: Is the CT/VT8H UR8HH covered by a warranty, and what does it include?
Yes. Each unit is backed by a 12-month warranty covering manufacturing defects and electrical performance under rated operating conditions. Prior to dispatch, every unit undergoes functional testing to verify contact resistance, mechanical operation, and dimensional conformance. Warranty claims are handled directly — contact [email protected] with your order reference and a description of the fault.
Q2: How do I verify compatibility with my existing CT/VT Series contactor before ordering?
The CT/VT8H UR8HH is designed for use with GE CT/VT Series contactor and relay frames. Compatibility is confirmed by matching the contactor frame designation (CT or VT series prefix) and the auxiliary contact block mounting interface. If you have the contactor nameplate data or the existing contact block part number, our technical team can confirm compatibility before you place an order. Send your inquiry to [email protected].
Q3: What is the recommended spare parts stocking strategy for CT/VT Series installations?
For facilities with three or more CT/VT Series contactors in service, we recommend maintaining a minimum of one CT/VT8H UR8HH contact block per five installed units, with a floor of two units regardless of installation count. High-cycle applications — such as pump, fan, or conveyor drives operating more than 100 starts per day — should carry a higher buffer. Contact blocks in these applications typically reach end-of-life within 18–36 months of installation.
Q4: How quickly can the CT/VT8H UR8HH be shipped, and what documentation is provided?
In-stock units are dispatched within 1–3 business days. Each shipment includes a packing list, a test report confirming pre-dispatch functional verification, and warranty documentation. Express shipping options are available for urgent maintenance situations. For international orders, customs documentation and HS code information are provided upon request. Contact +86 18359293191 or [email protected] for lead time confirmation on your specific destination.
Click Quote This Model and the Part Number field will auto-fill with CT/VT8H UR8HH.