FUJI Electric NP1X3206-W Original Industrial Spare NP1
NP1X3206-WOriginal FUJI Electric NP1X3206-W NP1 Series rack power supply, 24VDC 6A 144W. Direct industrial replacement, 12-month warranty, tested before shipment.
Request availability, condition, lead time and export shipping details for SC-1N.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The FUJI SC-1N is a 9A AC magnetic contactor from FUJI Electric’s proven SC Series, engineered for reliable motor control in industrial panels, machine tools, conveyor systems, pump stations, and process automation lines. As a genuine original spare part, the SC-1N delivers the switching precision and thermal endurance that maintenance engineers depend on during scheduled overhauls, emergency replacements, and long-term preventive maintenance programs. Whether you are managing a single control cabinet or maintaining a fleet of production lines, stocking the SC-1N as a certified replacement component is a foundational decision for operational continuity.
Industrial facilities running FUJI SC Series contactors benefit from a well-documented compatibility matrix, consistent coil voltage options, and standardized mounting dimensions that allow direct drop-in replacement without rewiring or panel modification. The SC-1N is particularly valued in aging automation systems where original components are no longer available through OEM channels, making it a critical asset for extending the service life of legacy equipment and avoiding costly full-panel upgrades.
| Parameter | Specification |
|---|---|
| Model / SKU | SC-1N |
| Brand | FUJI Electric |
| Series | SC Series |
| Rated Current (AC-3) | 9A |
| Motor Rating (400V) | 4 kW |
| Coil Voltage Options | AC 24V / 110V / 220V / 380V (specify on order) |
| Pole Configuration | 3-pole main contacts + 1NO auxiliary |
| Mounting | DIN rail / screw mount, direct panel installation |
| Enclosure Rating | IP20 (panel-mounted) |
| Ambient Temperature | -5°C to +60°C operating |
| Mechanical Endurance | ≥10 million operations |
| Electrical Endurance (AC-3) | ≥1 million operations |
| Compatibility | Direct replacement for FUJI SC-0, SC-1N, SC-2N series panels |
| Origin | Japan |
| Warranty | 12 Months from date of shipment |
| Pre-shipment Testing | Full electrical continuity and coil actuation test performed before dispatch |
A magnetic contactor like the SC-1N rarely fails in isolation. In most industrial environments, contactor degradation is a symptom of broader electrical stress across the motor control circuit. When replacing the SC-1N during a scheduled shutdown or emergency repair, experienced maintenance teams use the opportunity to inspect and, where necessary, replace adjacent components that share the same electrical load cycle.
Begin with the thermal overload relay paired to the SC-1N — in FUJI SC Series panels, the TR-0N or TR-1N overload relay is the most common companion component, and its bimetal strips accumulate fatigue at the same rate as the contactor’s main contacts. A contactor replacement without overload relay inspection is an incomplete repair. Similarly, the control circuit fuse module protecting the coil supply line should be verified for continuity and replaced if showing signs of thermal discoloration.
Moving upstream in the control cabinet, the FUJI BW Series molded case circuit breaker (MCCB) feeding the motor branch circuit should be exercised through several manual trip-and-reset cycles to confirm its trip mechanism has not seized from inactivity. If the panel includes a FUJI CP30 series miniature circuit breaker on the control voltage rail, inspect its terminals for oxidation, particularly in humid or coastal environments.
For panels incorporating PLC-driven motor control, the digital output module commanding the SC-1N coil deserves attention. Output transistors or relay contacts on modules such as FUJI MICREX-SX or compatible third-party I/O cards can develop high-resistance switching behavior that causes intermittent contactor chatter — a failure mode that accelerates contact wear and is often misdiagnosed as a contactor fault. Replacing the SC-1N without verifying the output module’s switching voltage under load will result in premature failure of the new contactor.
Terminal blocks and control wiring within the same cabinet section should be torqued to specification and inspected for insulation cracking, especially on conductors routed near heat-generating components. FUJI or equivalent DIN rail terminal strips with integrated test points simplify this process and reduce diagnostic time during future inspections. Where signal isolation is required between the PLC output and the contactor coil, a signal isolator or interposing relay module provides an additional layer of protection for the control system.
Finally, if the SC-1N is part of a star-delta starter or reversing contactor circuit, the interlocking contactors — typically SC-1N units on both the star and delta positions — should be replaced as a matched set to ensure uniform contact wear and consistent switching timing. Mismatched contact wear between interlocked contactors is a leading cause of phase-to-phase faults during motor starting sequences.
The SC-1N was designed as a direct successor to earlier FUJI SC-0 contactors, sharing the same panel footprint and terminal layout. This backward compatibility makes the SC-1N the preferred replacement for facilities still operating equipment built around the SC-0 specification, eliminating the need for panel modification or auxiliary adapter plates. For systems originally specified with third-party contactors of equivalent rating, the SC-1N’s standardized IEC AC-3 rating and DIN rail mounting ensure straightforward substitution with minimal engineering review.
Procurement teams managing multi-site operations benefit from standardizing on the SC-1N across all 9A motor control applications, reducing the number of unique spare part numbers held in inventory and simplifying technician training. A recommended minimum stock level of two to four units per active production line provides adequate buffer for both planned maintenance cycles and unplanned failures, with typical mean time between replacements in continuous-duty applications ranging from three to seven years depending on switching frequency and ambient conditions.
All SC-1N units supplied by TOPNLMS are sourced as original FUJI Electric components, individually tested for coil actuation voltage, contact resistance, and mechanical operation prior to shipment. Units are packaged in anti-static protective packaging with original manufacturer labeling intact, and each shipment includes a test record. The 12-month warranty covers manufacturing defects and covers return or replacement at no additional freight cost to the buyer.
Q1: Is the SC-1N a direct replacement for the FUJI SC-0 contactor?
Yes. The SC-1N shares the same panel mounting footprint and terminal pitch as the SC-0, making it a direct mechanical and electrical replacement in most applications. Verify coil voltage compatibility before installation, as coil voltage options differ between legacy and current production batches.
Q2: What is the recommended inventory quantity for a production facility?
For continuous-duty motor control applications, we recommend holding a minimum of two SC-1N units per active production line as on-site spares. Facilities with high switching frequency or harsh environments (high ambient temperature, vibration, or humidity) should increase this to four units and schedule annual contact inspection intervals.
Q3: How is the SC-1N tested before shipment?
Every SC-1N unit undergoes a pre-shipment inspection that includes coil actuation at rated voltage, main contact continuity verification across all three poles, and auxiliary contact function check. A test record is included with each shipment. Units that do not pass all checks are quarantined and not dispatched.
Q4: What does the 12-month warranty cover, and how is a warranty claim processed?
The 12-month warranty covers manufacturing defects in materials and workmanship from the date of shipment. It does not cover damage resulting from incorrect installation, overvoltage, or mechanical impact. To initiate a warranty claim, contact [email protected] with your order number and a description of the fault. Replacement units are dispatched upon confirmation of the defect, and return freight for confirmed warranty cases is covered by TOPNLMS.
Click Quote This Model and the Part Number field will auto-fill with SC-1N.