FUJI Electric NP2L-RP1 Original Industrial Spare NP2L Compatible
NP2L-RP1Original FUJI Electric NP2L-RP1 PLC Bus Repeater Unit. NP2L Series compatible, industrial-grade replacement. 12-month warranty. Fast global shipping.
Request availability, condition, lead time and export shipping details for NP1PH-08.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Fuji Electric NP1PH-08 is a high-performance CPU module designed for the MICREX-NX programmable logic controller platform — one of Fuji Electric’s most widely deployed industrial automation architectures across Asia-Pacific manufacturing, utilities, and process industries. As legacy MICREX-F and early MICREX-NX installations approach end-of-life, the NP1PH-08 represents the most direct, field-proven upgrade path that preserves existing wiring infrastructure, cabinet space, and communication topology while delivering modern processing capability and expanded I/O capacity.
Whether you are replacing a failed unit on an active production line, executing a planned migration from an older MICREX-NX CPU variant, or building a spare-parts inventory to protect against unplanned downtime, the NP1PH-08 is engineered to slot into your existing system with minimal disruption. Its compact DIN-rail form factor matches the mechanical footprint of predecessor modules, and its program memory architecture is compatible with projects developed in Fuji Electric’s D300win programming environment, significantly reducing re-commissioning time.
| Parameter | Legacy / Predecessor Models | Fuji Electric NP1PH-08 |
|---|---|---|
| Platform | MICREX-F, Early MICREX-NX | MICREX-NX |
| Module Type | CPU Module | CPU Module |
| Mounting | DIN Rail / Backplane Rack | DIN Rail / Backplane Rack |
| Communication Ports | RS-232C / RS-485 (varies) | RS-232C, RS-485, Ethernet (model-dependent) |
| Programming Software | D300win (legacy versions) | D300win (current versions) |
| I/O Expansion | NP1X / NP1Y series I/O modules | NP1X / NP1Y series I/O modules (compatible) |
| Power Supply | 24 VDC / 100–240 VAC (via NP1PS series) | 24 VDC / 100–240 VAC (via NP1PS series) |
| Cabinet Space | Standard MICREX-NX slot width | Identical slot width — no cabinet modification required |
| Replacement Complexity | — | Low — wiring and rack connectors retained |
| Warranty | — | 12-Month Warranty (TOPNLMS) |
A successful MICREX-NX migration rarely involves the CPU module alone. In most field scenarios, the NP1PH-08 is deployed alongside a suite of complementary modules that together form a complete, modernized control system. The NP1PS-24 power supply module provides stable 24 VDC rail power to the CPU and I/O bus, and its direct compatibility with the NP1PH-08 backplane eliminates the need for any power wiring changes during the swap.
On the I/O side, existing NP1X series digital input modules and NP1Y series digital output modules remain fully compatible with the NP1PH-08, meaning field wiring to sensors, actuators, solenoids, and relay coils can be left entirely intact. For analog signal loops — common in temperature, pressure, and flow control applications — the NP1AX analog input module and NP1AY analog output module continue to operate without reconfiguration.
Communication continuity is equally important during migration. The NP1PH-08 supports Modbus RTU and Modbus TCP protocols natively, allowing it to maintain existing links to SCADA systems, HMI panels, and remote I/O stations without protocol gateway additions. Where legacy installations use FL-net or OPCN-1 industrial networks, the NP1PH-08’s communication expansion slots accept the corresponding NP1L-RS4 serial communication module or NP1L-ET1 Ethernet module to preserve those network topologies.
For sites upgrading from older MICREX-F hardware, a signal isolator or terminal conversion module may be required at the field wiring interface to bridge any connector pitch differences. In such cases, TOPNLMS can advise on appropriate terminal adapter solutions to ensure a clean, code-compliant installation. The NP1W-series expansion base units are also available for applications requiring additional I/O slots beyond the base rack capacity.
HMI continuity is another key consideration. Fuji Electric V9 series HMI panels communicate natively with the MICREX-NX platform over RS-232C or Ethernet, and the NP1PH-08 maintains full compatibility with existing V9 screen projects, eliminating the need for HMI reprogramming during the CPU upgrade.
Q1: Can I reuse my existing field wiring when replacing the CPU with the NP1PH-08?
Yes. The NP1PH-08 uses the same backplane connector and rack slot standard as other MICREX-NX CPU modules. Field wiring connects to I/O modules — not directly to the CPU — so no rewiring is required at the terminal block level. Only the CPU module itself is swapped.
Q2: Is my existing D300win program compatible with the NP1PH-08?
In most cases, yes. Programs developed for MICREX-NX CPUs in D300win can be downloaded to the NP1PH-08 with minimal or no modification. For migrations from MICREX-F, a program conversion step is required, but D300win includes a migration utility to assist with this process. TOPNLMS recommends a bench test before field deployment.
Q3: What communication protocols does the NP1PH-08 support, and will my SCADA link be preserved?
The NP1PH-08 supports RS-232C, RS-485, Modbus RTU, Modbus TCP, and FL-net (via expansion modules). If your SCADA system communicates via any of these protocols, the link can be preserved without a protocol converter. Ethernet-based SCADA connections are supported through the NP1L-ET1 expansion module.
Q4: How do I handle the physical installation in a tight control cabinet?
The NP1PH-08 occupies the same physical slot width as standard MICREX-NX CPU modules. No cabinet modification, additional DIN rail space, or ventilation changes are required for a like-for-like CPU replacement. For full system expansions, the NP1W expansion base can be mounted on an adjacent DIN rail section.
Every Fuji Electric NP1PH-08 supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each unit undergoes a functional power-on test and visual inspection to verify connector integrity, firmware version, and absence of physical damage. Units that do not pass inspection are not shipped.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund within the warranty period. Our technical team is available to assist with installation questions, compatibility verification, and commissioning support via email and phone. We maintain buffer stock of high-demand MICREX-NX components to support rapid replacement requests, minimizing production downtime for our customers.
Orders are processed within 1–2 business days. International express shipping (DHL, FedEx, UPS) is available to most destinations, with typical transit times of 3–7 business days. A commercial invoice, packing list, and test record are included with every shipment to support customs clearance and incoming inspection.
For volume orders, long-term supply agreements, or urgent replacement requirements, please contact our sales team directly for priority handling.
Click Quote This Model and the Part Number field will auto-fill with NP1PH-08.