The FieldServe PS56-BAS-073 is a BACnet/IP communication module engineered for the PS56 Series control platform. As building automation and industrial control systems age, facilities managers and system integrators increasingly face the challenge of maintaining or replacing discontinued communication modules without triggering a full-system overhaul. The PS56-BAS-073 is purpose-built to address exactly this scenario — delivering a seamless, drop-in upgrade path that preserves existing wiring infrastructure, rack geometry, and BACnet/IP network topology while restoring full communication capability to legacy PS56-based control cabinets.
Whether you are replacing a failed unit, pre-positioning critical spares, or executing a phased migration from an older BACnet MS/TP or proprietary serial architecture to a modern BACnet/IP backbone, the PS56-BAS-073 provides the compatibility and reliability that industrial procurement teams demand. This module ships from verified stock in Xiamen, China, with full pre-shipment functional testing and a 12-month replacement warranty.
| Parameter | Legacy / Predecessor Models | PS56-BAS-073 (This Unit) |
|---|---|---|
| Communication Protocol | BACnet MS/TP, Proprietary Serial | BACnet/IP (ASHRAE 135 compliant) |
| Physical Interface | RS-485 terminal block | RJ-45 Ethernet (10/100 Mbps) |
| Rack / Backplane Slot | PS56 Series standard slot | PS56 Series standard slot (direct fit) |
| Power Supply | 24 VDC via backplane | 24 VDC via backplane (no external PSU required) |
| Configuration Tool | Legacy serial programmer | Web browser / BACnet configuration utility |
| Max BACnet Objects | Varies by predecessor | Up to 500 BACnet objects supported |
| Cabinet Space | Single-slot module | Single-slot module (identical footprint) |
| Replacement Recommendation | Direct swap; update IP parameters post-install | ✔ Confirmed drop-in for PS56 Series racks |
| Warranty | — | 12-Month Replacement Warranty |
A successful migration to the PS56-BAS-073 rarely involves the communication module alone. In practice, system integrators working on PS56 Series control cabinets typically address several adjacent components during the same maintenance window to minimize repeat downtime. The PS56 Series backplane and rack chassis should be inspected for corrosion or connector wear before re-seating the new module; a degraded backplane connector is a common root cause of intermittent communication faults that are misdiagnosed as module failure.
On the power side, the PS56-PWR-024 24 VDC power supply module is frequently replaced in tandem, particularly in installations where the original PSU has been running continuously for more than five years. Pairing a fresh power module with the PS56-BAS-073 eliminates voltage sag as a variable during post-installation commissioning. Similarly, the PS56-CPU controller module firmware should be verified for BACnet/IP compatibility; older firmware revisions may require an update before the network stack correctly enumerates the new communication module.
For sites migrating from a legacy RS-485 BACnet MS/TP segment, a BACnet MS/TP to BACnet/IP router — such as those in the FieldServe PS56-RTR series — can bridge the old field bus to the new IP backbone during a phased cutover, allowing existing MS/TP field devices like PS56-AIO analog I/O modules and PS56-DIO digital I/O modules to remain online while the network is restructured. This approach is particularly valuable in occupied buildings where a hard cutover would trigger HVAC or access control alarms.
Wiring changes are minimal when replacing a BACnet MS/TP module with the PS56-BAS-073: the RS-485 terminal block is retired and a standard Cat5e or Cat6 patch cable connects the module’s RJ-45 port to the nearest managed Ethernet switch. If the control cabinet does not already have an Ethernet switch, a DIN-rail mounted industrial Ethernet switch (24 VDC powered) can be installed in the same cabinet with minimal space impact. For sites requiring signal isolation between the BACnet/IP segment and the plant LAN, a signal isolator or managed VLAN switch is recommended to protect the BMS network from broadcast storms originating on the corporate network.
Finally, commissioning engineers should have a FieldServe PS56 programming cable and configuration software available on-site to verify object mapping and confirm that all BACnet device instance numbers are unique on the IP subnet before going live. Duplicate device instances are the single most common cause of post-migration communication failures in multi-controller BACnet/IP installations.
Q: Can I reuse existing RS-485 wiring after installing the PS56-BAS-073?
A: No. The PS56-BAS-073 communicates exclusively over Ethernet/IP. Existing RS-485 field wiring to BACnet MS/TP devices must be terminated at a BACnet router or replaced with Ethernet runs. However, the backplane wiring and power connections within the PS56 rack are fully reused.
Q: Do I need to rewrite my BACnet control programs?
A: In most cases, no. BACnet/IP uses the same object model (AV, AO, BV, BO, etc.) as BACnet MS/TP. If your controller logic references BACnet objects by instance number rather than by physical address, the program can be retained with only the network layer parameters updated (IP address, subnet mask, UDP port 47808).
Q: Is the PS56-BAS-073 compatible with third-party BMS platforms such as Niagara, Tridium, or Siemens Desigo?
A: Yes. The module is ASHRAE 135 BACnet/IP compliant and has been tested for interoperability with major BMS platforms. A BACnet/IP device profile (B-BC or B-AAC) should be confirmed with your BMS integrator prior to final commissioning.
Q: What physical space does the module require in the control cabinet?
A: The PS56-BAS-073 occupies a single standard PS56 Series slot — identical to the predecessor module it replaces. No additional DIN rail space or panel cutouts are required beyond routing a Cat5e/Cat6 cable to the RJ-45 port.
Q: How long does commissioning typically take after physical installation?
A: For a direct replacement on a site with an existing BACnet/IP infrastructure, commissioning typically takes 30–90 minutes: assign IP parameters, verify device instance uniqueness, confirm object discovery from the BMS, and validate alarm routing. Sites migrating from MS/TP should budget an additional 2–4 hours for router configuration and object re-mapping.
Q: Can the module be configured without taking the controller offline?
A: Initial IP parameter assignment requires a brief controller restart. Subsequent BACnet object configuration can be performed online via the module’s web interface without interrupting the PS56 CPU’s scan cycle.
Every PS56-BAS-073 unit shipped by TOPNLMS undergoes a pre-shipment functional test that verifies backplane communication, Ethernet link establishment, BACnet/IP stack initialization, and object enumeration. Units that do not pass all test criteria are quarantined and not offered for sale.
All units are covered by a 12-month replacement warranty from the date of shipment. In the event of a confirmed module failure within the warranty period, TOPNLMS will ship a replacement unit at no additional charge. Warranty claims are processed within 2 business days of fault confirmation, and replacement units are dispatched from Xiamen stock with priority shipping to minimize site downtime.
For procurement teams requiring documentation, TOPNLMS provides a test report, packing list, and commercial invoice with every shipment. Export compliance documentation for CN-origin goods is available on request. Bulk orders of 5 units or more qualify for reserved stock allocation and extended lead-time guarantees — contact our sales team to discuss framework agreements.
TOPNLMS maintains a dedicated after-sales response channel for technical queries related to installation, commissioning, and compatibility. Response time is within 24 hours on business days. Our technical team has direct experience with PS56 Series deployments across HVAC, access control, and industrial process control applications.
For urgent replacement requirements, same-day dispatch is available for orders confirmed before 14:00 CST. International express delivery (DHL, FedEx, UPS) typically achieves 3–5 business day transit to most destinations in Europe, Southeast Asia, the Middle East, and the Americas.
Click Quote This Model and the Part Number field will auto-fill with PS56-BAS-073.