Language English USD Currency
Call WhatsApp RFQ
Endress+Hauser Industrial Automation Part

Endress+Hauser CYK10-A151 Original Industrial Spare Memosens Compatible

Request availability, condition, lead time and export shipping details for CYK10-A151.

Endress+Hauser

CYK10-A151

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberCYK10-A151
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesOther series
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Endress+Hauser CYK10-A151 Original Industrial Spare Memosens Compatible: System Stability Through Precision Sensor Connectivity

In continuous process industries — water treatment, chemical manufacturing, food & beverage, and pharmaceutical production — the integrity of your analytical measurement chain is non-negotiable. The Endress+Hauser CYK10-A151 Memosens digital sensor cable is the critical link between your pH, ORP, or dissolved oxygen (DO) sensor and your transmitter. When this cable degrades, corrodes, or fails, your entire measurement loop goes blind — triggering alarms, forcing manual sampling, and risking process excursions that cost far more than a planned spare part ever would.

Sourced as an original Endress+Hauser spare component, the CYK10-A151 is engineered to maintain the full digital Memosens protocol integrity: galvanic isolation, inductive signal transmission, and onboard sensor memory (EEPROM) communication. Unlike generic cables that degrade signal quality or introduce ground loops, the CYK10-A151 preserves calibration data transfer and sensor diagnostics — keeping your HART or PROFIBUS transmitter (such as the Liquiline CM442, CM444, or CM448) fully informed of sensor status at all times.

Critical Technical Specs Table

Parameter Specification
Part Number / SKU CYK10-A151
Brand Endress+Hauser
Series Memosens CYK10
Product Type Digital Sensor Interface Cable (Memosens Protocol)
Compatible Sensors pH, ORP (Redox), Dissolved Oxygen (DO) — Memosens-enabled sensors
Compatible Transmitters Liquiline CM442, CM444, CM448; Mycom S CPM153; Liquisys M CPM223/253
Signal Transmission Inductive (galvanically isolated), digital Memosens protocol
Cable Length Refer to product variant / order confirmation
Connector Type Memosens plug (sensor end) + M12 or cable end (transmitter side)
IP Protection IP68 (submersible, suitable for wet and immersion applications)
Operating Temperature -20 °C to +80 °C
Country of Origin Germany
Application Environment Water/wastewater, chemical dosing, food processing, pharma CIP/SIP
Maintenance Recommendation Inspect every 6–12 months; replace at first sign of jacket cracking or connector corrosion
Warranty 12 Months — tested before dispatch

Preventive Maintenance Strategy

A sensor cable failure rarely occurs in isolation. In most process plants, the CYK10-A151 operates within a broader analytical measurement assembly that includes the sensor head, the transmitter, the process connection, and the control system I/O. A disciplined preventive maintenance program should treat the entire loop as a single reliability unit.

When scheduling a cable inspection or replacement, maintenance engineers should simultaneously verify the condition of the Endress+Hauser Orbisint CPS11D or Memosens CPS31D pH sensor — the most common sensor partners for the CYK10 cable family. Sensor glass membranes and reference junctions have finite service lives, and replacing a degraded cable while leaving a worn sensor in place simply shifts the failure point without restoring measurement accuracy.

At the transmitter end, confirm that the Liquiline CM442 or CM444 transmitter firmware is current and that the Memosens input module is seated correctly. Loose module connections are a frequent source of intermittent communication faults that are misdiagnosed as cable failures. If your plant runs multiple analytical loops, it is worth maintaining a small buffer stock of Memosens input modules (e.g., 2DS module for CM44x) alongside your cable spares.

For installations in aggressive chemical environments — chlorine dosing stations, acid neutralization tanks, or CIP circuits — inspect the process connection assembly, including the immersion fitting, retractable assembly (such as the Cleanfit CPA450 or CPA875), and any associated O-rings and seals. These components are subject to chemical attack and mechanical wear independent of the sensor and cable. Replacing the cable without checking the retractable assembly housing can result in a new cable being immediately exposed to the same conditions that destroyed the previous one.

In control cabinet environments, verify the integrity of the terminal blocks and cable glands at the transmitter entry point. Moisture ingress through degraded cable glands is a leading cause of premature cable jacket failure and connector corrosion. Paired with a periodic check of the 24 VDC power supply module feeding the transmitter, this cabinet-level inspection takes less than 15 minutes and can prevent hours of unplanned downtime.

For plants operating legacy Mycom S CPM153 or Liquisys M CPM223 transmitters, the CYK10-A151 remains fully compatible — but it is advisable to also stock the relevant CPM153 or CPM223 spare fuses and terminal connectors, as these older transmitter platforms are increasingly difficult to source on short notice. Proactive inventory of both the cable and the transmitter consumables significantly reduces mean time to repair (MTTR) when a fault occurs on a legacy loop.

Finally, for multi-parameter monitoring stations that combine pH, DO, and conductivity measurements, consider maintaining parallel spares for the Condumax CLS21D conductivity sensor and its associated Memosens cable. Analytical stations that go offline due to a single sensor or cable failure often take the entire measurement skid out of service, impacting multiple process variables simultaneously.

Strategic Replacement Solutions

The CYK10-A151 is a direct original replacement for earlier CYK10 cable variants used across the Endress+Hauser Memosens ecosystem. Plants that originally commissioned their analytical loops with CYK10-A050, CYK10-A101, or CYK10-A121 cables can upgrade to the CYK10-A151 without any transmitter reconfiguration — the Memosens protocol is backward compatible across the CYK10 family.

For maintenance teams managing aging analytical infrastructure, the CYK10-A151 offers a cost-effective path to extending system life without capital investment in new transmitters or process connections. Rather than replacing an entire measurement assembly when a cable fails, a targeted cable swap restores full digital communication, preserves the sensor’s onboard calibration history, and returns the loop to service — typically within 30 minutes for a trained technician.

Procurement teams managing multi-site operations benefit from standardizing on the CYK10-A151 as the single cable SKU across all Memosens-equipped loops. This simplifies spare parts inventory, reduces the risk of incorrect cable installation, and enables bulk purchasing that lowers per-unit cost. Combined with a 12-month warranty and pre-shipment electrical testing, the CYK10-A151 from TOPNLMS provides a reliable, auditable spare parts solution for ISO-certified maintenance programs.

Support FAQ

Q1: Is the CYK10-A151 compatible with all Memosens sensors, regardless of measurement parameter?
The CYK10-A151 is compatible with all Endress+Hauser Memosens-enabled sensors for pH, ORP, and dissolved oxygen measurement. It is not designed for conductivity or turbidity sensors, which use different Memosens cable variants. Always verify the sensor’s Memosens connector type before ordering.

Q2: What is the recommended replacement interval for the CYK10-A151 in continuous immersion applications?
Endress+Hauser recommends inspecting Memosens cables every 6 to 12 months in continuous immersion or chemically aggressive environments. Visible jacket cracking, connector discoloration, or intermittent Memosens communication errors are indicators of immediate replacement need. In clean water applications, service life may extend to 3–5 years with proper installation.

Q3: How is the CYK10-A151 tested before shipment, and what does the 12-month warranty cover?
Every CYK10-A151 unit dispatched by TOPNLMS undergoes electrical continuity testing and Memosens protocol verification prior to shipment. The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. It does not cover damage resulting from mechanical abuse, chemical incompatibility beyond rated specifications, or incorrect installation.

Q4: Can I use the CYK10-A151 to replace a cable on a transmitter that is not from Endress+Hauser?
The Memosens protocol is an Endress+Hauser proprietary standard. The CYK10-A151 is designed exclusively for use with Memosens-compatible transmitters from Endress+Hauser. It is not compatible with third-party transmitters unless those transmitters have been specifically certified for Memosens protocol support. Contact TOPNLMS for compatibility verification before ordering for non-standard applications.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with CYK10-A151.