Endress+Hauser CLS50-A1B6 Ruggedized Optical Turbidity Sensor
CLS50-A1B6Buy Endress+Hauser CLS50-A1B6 inline optical turbidity sensor. IP68, SIL-rated, EMC-hardened. 12-month warranty, pre-shipment tested. Fast dispatch — [email protected].
Request availability, condition, lead time and export shipping details for COS61-A2F0.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Endress+Hauser COS61-A2F0 is a certified original optical dissolved oxygen sensor from the Oxymax COS61 series, engineered for continuous, high-precision measurement in demanding industrial process environments. Deployed across wastewater treatment, pharmaceutical bioprocessing, food & beverage production, and chemical plant aeration control, this sensor delivers the measurement reliability that modern process automation demands. Maintaining a verified spare of the COS61-A2F0 in your inventory is not merely a procurement decision — it is a cornerstone of your plant’s uptime strategy and a direct investment in process continuity.
Industrial facilities that depend on dissolved oxygen measurement for closed-loop aeration control cannot afford unplanned sensor failures. A single degraded or failed DO sensor can trigger aeration system imbalances, regulatory non-compliance events, or costly batch losses. The COS61-A2F0, with its optical luminescence-based measurement principle, eliminates the electrolyte replacement cycles associated with polarographic sensors, significantly reducing scheduled maintenance burden while extending calibration intervals. Stocking this sensor as a certified original spare ensures that your maintenance team can execute a rapid, like-for-like replacement without recalibration delays or compatibility concerns — keeping your process loop stable and your compliance records intact.
| Parameter | Specification |
|---|---|
| Part Number / SKU | COS61-A2F0 |
| Series | Oxymax COS61 |
| Manufacturer | Endress+Hauser (E+H) |
| Measurement Principle | Optical / Luminescence (non-consumable membrane) |
| Measured Variable | Dissolved Oxygen (DO), Saturation (%) |
| Measuring Range | 0–20 mg/L (ppm); 0–200% saturation |
| Process Temperature | 0 °C to +50 °C (operating) |
| Process Pressure | Up to 10 bar (installation dependent) |
| Communication Protocol | Memosens digital (M12 connector) |
| Compatible Cable | CYK10 Memosens digital cable |
| Housing / Protection | PPS body; IP68 rated |
| Country of Origin | Germany |
| Transmitter Compatibility | Liquiline CM442 / CM444 / CM448; Mycom S COM253; Liquisys M COM223 / COM253 |
| Retractable Assembly | CYA611 / CYA612 compatible |
| Application Environment | Wastewater, bioprocessing, food & beverage, chemical aeration |
| Maintenance Interval | Optical cap (COS61-CAP) replacement every 6–12 months |
| Pre-Shipment Testing | Memosens communication integrity & optical cap condition verified |
| Warranty | 12 Months – TOPNLMS verified original |
A disciplined preventive maintenance program for dissolved oxygen measurement systems extends well beyond the sensor itself. When scheduling a COS61-A2F0 inspection or replacement, experienced instrumentation engineers treat it as an opportunity to audit the entire measurement loop and surrounding process control infrastructure — reducing the risk of cascading failures and maximizing the value of each planned shutdown window.
Begin with the Memosens digital cable CYK10 — the signal cable connecting the COS61-A2F0 to the transmitter. Cable jacket degradation, connector corrosion, or moisture ingress at the M12 connector are common failure modes in wet process environments. A spare CYK10 should be co-stocked with every COS61-A2F0 unit. Simultaneously, inspect the retractable assembly CYA611 or CYA612 for seal wear and guide tube corrosion; a failed assembly seal can expose the sensor to uncontrolled process pressure during extraction, causing irreversible damage to both the sensor and the installation point.
At the transmitter end, verify the Liquiline CM442 or CM444 multiparameter transmitter firmware version and input card seating. Loose module cards or outdated firmware can cause intermittent Memosens communication faults that are frequently misdiagnosed as sensor failure. If your facility runs older installations, the Mycom S COM253 or Liquisys M COM223 transmitters should be checked for display module integrity and power supply rail stability — a degraded 24 VDC power supply module feeding the transmitter rack is a silent contributor to measurement drift that often goes undetected until a process upset occurs.
The COS61-CAP optical sensor cap is a consumable that must be tracked separately from the sensor body. Cap fouling from biofilm, oil contamination, or chemical exposure is the leading cause of COS61 measurement error in high-fouling environments such as activated sludge aeration basins. Maintaining a minimum of two spare caps per installed sensor is standard practice. During cap replacement, also inspect the sensor O-rings and the immersion tube for scaling or biological growth that could restrict flow across the optical window.
During control cabinet inspections, evaluate the terminal blocks and field junction boxes serving the DO measurement loop. Loose terminals or corroded DIN rail-mounted terminal strips introduce signal noise that can manifest as erratic DO readings. In facilities with multiple analog 4–20 mA loops running alongside Memosens digital circuits, a signal isolator or galvanic separator module may be warranted to eliminate ground loop interference. Finally, if your process uses automated dosing or aeration control triggered by DO setpoints, verify the integrity of the analog input I/O module in the PLC or DCS handling the transmitter output — a degraded input card can corrupt the DO control loop even when the sensor itself is performing correctly. Pairing this audit with a review of the communication module (PROFIBUS DP or HART adapter) installed in the Liquiline transmitter ensures end-to-end signal chain integrity from sensor to control system.
The COS61-A2F0 is a direct original replacement for aging Oxymax COS61 installations that may have been in continuous service for five years or more. Unlike third-party alternatives, the original E+H COS61-A2F0 retains full Memosens digital protocol compatibility, ensuring that all sensor diagnostic data — including calibration history, operating hours, and temperature compensation coefficients — transfers seamlessly to the connected Liquiline or Liquisys transmitter without manual parameter re-entry. This is a critical advantage in regulated industries where calibration traceability is an audit requirement.
For facilities transitioning from older polarographic DO sensors such as the Oxymax W COS4 or COS5 series, the COS61-A2F0 represents a generational upgrade: no electrolyte, no membrane replacement, and a significantly extended calibration interval. The optical measurement principle is immune to hydrogen sulfide poisoning and chlorine interference — two common failure accelerators in municipal wastewater applications. This translates to fewer emergency callouts, reduced consumable spend, and a measurable improvement in measurement availability across the operating year.
Procurement teams should note that sourcing the COS61-A2F0 through TOPNLMS provides access to verified original stock with full traceability documentation, pre-shipment electrical testing, and a 12-month warranty covering manufacturing defects. Each unit is inspected prior to dispatch, and calibration data sheets are available upon request. Lead times are typically 3–7 business days for in-stock units, supporting both planned maintenance schedules and emergency breakdown scenarios. For multi-site procurement or annual maintenance contracts requiring multiple COS61-A2F0 units alongside associated accessories, volume pricing and consolidated shipment options are available — contact our technical sales team for a tailored quotation.
Q1: Is the COS61-A2F0 a genuine original Endress+Hauser part?
Yes. All COS61-A2F0 units supplied by TOPNLMS are sourced as original Endress+Hauser components. Each unit undergoes pre-shipment Memosens communication verification and optical cap inspection. A 12-month warranty against manufacturing defects is included, and traceability documentation is available upon request.
Q2: Which transmitters are compatible with the COS61-A2F0?
The COS61-A2F0 uses the Memosens digital protocol and is compatible with the Endress+Hauser Liquiline CM442, CM444, and CM448 multiparameter transmitters, as well as the Mycom S COM253 and Liquisys M COM223/COM253 series. Confirm your transmitter firmware supports the Memosens COS61 sensor type before installation. Firmware update files are available from Endress+Hauser’s W@M portal.
Q3: How should I plan my spare parts inventory for COS61 installations?
For continuous process applications, maintain at least one COS61-A2F0 sensor per three installed units as a rotating spare. Co-stock CYK10 Memosens cables and COS61-CAP optical caps. For critical aeration control loops, a dedicated hot-spare sensor stored in original packaging at ambient temperature is recommended to support same-shift replacement during unplanned outages. Annual inventory reviews aligned with planned shutdown schedules help avoid emergency procurement premiums.
Q4: What pre-shipment testing is performed, and what does the 12-month warranty cover?
Each COS61-A2F0 unit is electrically verified for Memosens communication integrity and optical cap condition prior to dispatch. Units are shipped in original or equivalent protective packaging with inspection records. The 12-month warranty period begins from the date of shipment and covers manufacturing defects. It does not cover damage resulting from improper installation, chemical overexposure beyond rated limits, or mechanical impact. For applications requiring factory calibration certificates, contact our technical team prior to order placement.
Click Quote This Model and the Part Number field will auto-fill with COS61-A2F0.