Emerson UES815S-24A Ruggedized Monitoring Module for Harsh Environments
UES815S-24AEmerson UES815S-24A DeltaV monitoring module for harsh industrial environments. Rugged, EMI-resistant, 12-month warranty. In stock — fast global shipping.
Request availability, condition, lead time and export shipping details for IC695CPE330-AFAT.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The EMERSON IC695CPE330-AFAT is a Dual-Core CPU module designed for the GE PACSystems RX3i control platform — one of the most widely deployed PLC architectures in process manufacturing, power generation, water treatment, and discrete automation. Sourced as an original spare, this module is a critical asset for any maintenance team responsible for keeping RX3i-based control systems operational. Whether you are managing a planned shutdown, responding to an unscheduled fault, or building a strategic spare parts inventory, the IC695CPE330-AFAT delivers the processing power and compatibility your system demands without requiring hardware redesign or software migration.
In industrial environments where control system downtime translates directly into production loss, having a verified, tested CPU module on the shelf is not optional — it is a maintenance imperative. The IC695CPE330-AFAT supports dual-core processing, enabling faster scan times and improved multitasking for complex ladder logic and function block programs. Its compatibility with the RX3i Universal Backplane family means it can be installed into existing cabinets without mechanical modification, preserving your wiring, I/O mapping, and network topology.
| Parameter | Specification |
|---|---|
| Part Number | IC695CPE330-AFAT |
| Brand / Manufacturer | EMERSON (GE Automation & Controls) |
| Series | PACSystems RX3i |
| Module Type | Dual-Core CPU Module |
| Processor | Dual-Core 1.2 GHz |
| User Memory | 64 MB program / 64 MB data |
| Communication Ports | Ethernet (2×), USB, RS-232 |
| Backplane Compatibility | IC695CHS007, IC695CHS012, IC695CHS016 Universal Backplanes |
| Operating Temperature | 0°C to 60°C |
| Power Supply Compatibility | IC695PSA040, IC695PSD040, IC695PSA140 |
| Programming Software | Proficy Machine Edition (PME) 8.0+ |
| Firmware | Field-upgradeable via USB / Ethernet |
| Mounting | Backplane slot 0 (dedicated CPU slot) |
| Certifications | CE, UL, cUL |
| Condition | Original / Genuine — Tested Before Shipment |
| Warranty | 12 Months from date of shipment |
A CPU module replacement is rarely an isolated event. When the IC695CPE330-AFAT is flagged for replacement — whether due to a fault code, thermal degradation, or end-of-life planning — experienced maintenance engineers use the opportunity to audit the entire control cabinet. This approach minimizes repeat downtime and extends the operational life of the surrounding system.
Begin with the power supply module (IC695PSA040 or IC695PSD040): CPU faults are frequently preceded by marginal power rail voltages. A power supply that is operating near its rated capacity under thermal stress should be replaced concurrently with the CPU to prevent a recurrence within the same maintenance window. Similarly, inspect the IC695CHS016 backplane for connector wear, corrosion on the bus contacts, and any signs of heat damage around the CPU slot.
Next, verify the integrity of your Ethernet communication modules such as the IC695ETM001. The RX3i CPU communicates with SCADA, historian, and HMI systems over Ethernet; a degraded ETM001 can cause intermittent communication faults that are often misdiagnosed as CPU failures. While the cabinet is open, inspect the IC695ALG600 analog input module and IC695MDL740 discrete output module for relay contact wear and signal drift — both are common failure points in high-cycle applications.
For systems running PROFIBUS DP or PROFINET field networks, check the IC695PBM300 PROFIBUS master module for firmware currency and cable termination integrity. Loose termination resistors on PROFIBUS segments are a leading cause of intermittent I/O faults that can trigger CPU diagnostic alarms. If your facility uses IC694MDL655 or IC694MDL754 I/O modules on legacy RX7i or Series 90-30 racks connected via the RX3i backplane, verify that the inter-rack cables and IC695CMM002 serial communication modules are within their rated service life.
Finally, review your IC695MEM003 expansion memory module if your application uses large data tables or recipe management. Proactive replacement of memory modules showing read/write errors prevents data corruption during CPU initialization. Documenting all module serial numbers, firmware versions, and replacement dates during this maintenance window creates a traceable spare parts record that supports future audits and insurance compliance.
The IC695CPE330-AFAT is a direct replacement for earlier RX3i CPU revisions including the IC695CPE330 (non-AFAT suffix) and the IC695CPU320. The AFAT hardware revision incorporates updated firmware compatibility and improved thermal management, making it the preferred choice for systems that will remain in service beyond 2030. Unlike third-party compatible modules, an original EMERSON IC695CPE330-AFAT retains full compatibility with Proficy Machine Edition project files without requiring logic re-compilation or I/O remapping — a critical advantage when replacement must be completed within a narrow maintenance window.
For facilities managing multiple RX3i racks across a plant floor, standardizing on the IC695CPE330-AFAT as the single approved CPU spare reduces inventory complexity and ensures that any technician can execute a replacement without consulting compatibility matrices. The module’s dual Ethernet ports support both the primary SCADA network and a dedicated programming/maintenance network, eliminating the need for a separate Ethernet switch in the control cabinet and reducing potential points of failure.
When replacing a CPU in a running system, always export the current project from Proficy Machine Edition before powering down, verify the replacement module firmware version matches or exceeds the original, and perform a full I/O force test before returning the system to automatic mode. TOPNLMS ships each IC695CPE330-AFAT with a pre-shipment functional test report, reducing commissioning time and providing documentation for your maintenance records.
Q1: Is the IC695CPE330-AFAT compatible with my existing RX3i backplane and I/O modules?
Yes. The IC695CPE330-AFAT is compatible with all IC695 Universal Backplanes (7, 12, and 16-slot) and supports the full range of RX3i I/O, communication, and specialty modules. No hardware or software changes are required when replacing an earlier IC695CPE330 revision.
Q2: What does the 12-month warranty cover?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions from the date of shipment. Each unit is tested before dispatch. Warranty claims are supported by our technical team at [email protected].
Q3: How is the module tested before shipment?
Each IC695CPE330-AFAT undergoes power-on functional verification, firmware version confirmation, and communication port testing. A test report is included with shipment documentation upon request.
Q4: What is the recommended spare parts strategy for RX3i systems?
For critical production lines, we recommend holding a minimum of one CPU module, one power supply, and one of each high-cycle I/O module type as on-site cold spares. For multi-rack installations, a warm spare rack pre-loaded with configured modules significantly reduces mean time to repair (MTTR) during unplanned outages.