VIBRO-METER CMC16 200-530-025-014 Replacement for VM600
CMC16 200-530-025-014VIBRO-METER CMC16 200-530-025-014 VM600 Series Condition Monitoring Card. Drop-in replacement & upgrade solution. 12-month warranty. Fast global shipping.
Request availability, condition, lead time and export shipping details for A-87.213.010-5541367626.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
When your Cerberus fire safety control system relies on the A-87.213.010 (5541367626) control board and the original unit reaches end-of-life, sourcing a verified replacement becomes a critical priority. TOPNLMS supplies the EACH A-87.213.010-5541367626 as a direct replacement and compatible upgrade solution for Cerberus fire detection and alarm control panels. This board is engineered to restore full system functionality with minimal downtime, preserving your existing wiring infrastructure, panel architecture, and communication topology.
The A-87.213.010-5541367626 is a core processing and control board used within Cerberus fire alarm control panels — a product line historically associated with Siemens Building Technologies and its predecessor brands. Many installations across industrial plants, commercial buildings, and critical infrastructure sites continue to operate on these legacy Cerberus platforms. When the original board fails or is discontinued, a like-for-like replacement that maintains electrical compatibility, connector pinout alignment, and firmware-level communication integrity is essential to avoid costly panel replacement or full system overhaul.
| Parameter | Original A-87.213.010-5541367626 | EACH Replacement Unit |
|---|---|---|
| SKU / Part Number | A-87.213.010 / 5541367626 | A-87.213.010-5541367626 (EACH) |
| Product Type | Fire Safety Control Board | Fire Safety Control Board (Replacement) |
| Brand / Series | Cerberus (Siemens lineage) | EACH — Cerberus-compatible series |
| Connector / Pinout | OEM board connector layout | Compatible pinout — direct board swap |
| Communication Protocol | Cerberus proprietary loop / panel bus | Compatible with Cerberus panel bus architecture |
| Installation Space | Standard Cerberus panel backplane slot | Same form factor — no panel modification required |
| Power Supply Compatibility | Panel-integrated 24 VDC supply | Compatible with existing panel 24 VDC rail |
| Wiring Compatibility | Existing field wiring retained | No rewiring required for standard replacement |
| Replacement Recommendation | — | Direct drop-in replacement; verify firmware revision |
| Warranty | OEM warranty (expired / discontinued) | 12-Month Warranty from TOPNLMS |
A successful migration from a failed or end-of-life Cerberus fire safety control board rarely involves a single component. In practice, field engineers replacing the A-87.213.010-5541367626 board often simultaneously address adjacent components that have experienced equivalent service hours or environmental stress. TOPNLMS maintains stock of the full ecosystem of parts required for a complete Cerberus panel restoration.
During the board replacement process, it is common to inspect and replace the Cerberus panel power supply module, which provides the regulated 24 VDC rail that feeds the control board and connected detector loops. If the power supply shows signs of capacitor aging or output ripple, replacing it alongside the control board eliminates a secondary failure point. Similarly, the Cerberus loop driver card — responsible for polling addressable detectors and call points across the SLC loop — should be tested for communication integrity before the system is returned to service.
For sites running multi-panel networked configurations, the Cerberus network communication module (panel-to-panel or panel-to-BMS gateway card) may require re-initialization after the control board swap, particularly if the board stores network node addressing parameters. Technicians should also verify the condition of the Cerberus display and operator interface board, which handles LED annunciation, LCD output, and keypad input — components that interact directly with the replaced control board via the internal panel bus.
In installations where the Cerberus panel interfaces with third-party building management systems via Modbus RTU, BACnet MS/TP, or dry-contact relay output modules, these interface cards should be re-tested post-replacement to confirm that protocol handshaking and alarm relay mapping remain intact. Where the original panel used a Cerberus printer interface module for event logging, this peripheral connection should also be verified after the board swap.
For sites undertaking a broader modernization — moving from the legacy Cerberus platform toward a current-generation fire alarm control panel — TOPNLMS can supply addressable detector bases, sounder bases, and zone expander modules compatible with modern Siemens Cerberus PRO or equivalent platforms, supporting a phased migration that preserves existing field cabling while upgrading the panel head-end.
Q: Can I replace the A-87.213.010-5541367626 without rewiring the field devices?
A: In the majority of standard installations, the replacement board uses the same connector layout and terminal block positions as the original. Existing field wiring — including detector loop cables, sounder circuits, and input/output module connections — can be retained without modification. Always verify the specific panel variant and wiring diagram before proceeding.
Q: Will the replacement board require firmware programming or configuration upload?
A: The control board may require configuration data to be restored from a panel backup or re-programmed via the panel’s service software. It is strongly recommended to back up the existing panel configuration (zone assignments, detector addresses, cause-and-effect logic, and network node parameters) before removing the original board. TOPNLMS can advise on configuration restoration procedures for common Cerberus panel variants.
Q: Is the communication protocol between the replacement board and existing loop devices compatible?
A: The EACH replacement board is designed to maintain compatibility with the Cerberus panel bus and SLC loop communication protocol used in the original installation. Addressable detectors, call points, and I/O modules on the existing loop should continue to communicate normally after the board swap. Protocol-level compatibility should be confirmed against the specific panel model and loop device firmware versions.
Q: Does the replacement board fit the existing panel backplane and enclosure?
A: The EACH A-87.213.010-5541367626 replacement is manufactured to the same physical form factor as the original board, including PCB dimensions, mounting hole positions, and edge connector alignment. No panel enclosure modification or backplane adapter is required for a standard replacement.
Q: What should be checked during commissioning after the board replacement?
A: Post-replacement commissioning should include: full panel power-up and self-test sequence, verification of all detector loop addresses, sounder circuit continuity test, input/output module function test, network communication check (if applicable), and a full cause-and-effect walk-test. Any fault conditions identified during commissioning should be resolved before returning the system to normal monitoring mode.
Every EACH A-87.213.010-5541367626 fire safety control board supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each unit undergoes functional inspection and electrical testing to verify board integrity, connector condition, and component health. Units that do not meet our quality standards are not shipped.
In the event of a warranty claim, TOPNLMS provides replacement support with priority processing to minimize system downtime. Our after-sales response team is available to assist with technical queries, compatibility confirmation, and return merchandise authorization (RMA) processing. We maintain buffer stock of high-demand Cerberus-compatible boards to support rapid replacement dispatch.
For procurement teams and maintenance contractors managing multi-site fire safety infrastructure, TOPNLMS offers volume purchasing arrangements, advance exchange programs, and documented test reports on request. All units are shipped with appropriate protective packaging to prevent transit damage, and tracking information is provided at the time of dispatch.
To place an order, confirm compatibility, or request a quotation, contact our technical sales team directly.
Click Quote This Model and the Part Number field will auto-fill with A-87.213.010-5541367626.