ABB 07KP64 GJR5240600R0101 Replacement for AC31 PLC
07KP64 GJR5240600R0101ABB 07KP64 GJR5240600R0101 RS232 RCOM Communication Processor replacement for AC31 PLC. Drop-in upgrade, 12-month warranty, fast global shipping from stock.
Request availability, condition, lead time and export shipping details for CI867K01-3BSE043660R1.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The ABB CI867K01 (part number 3BSE043660R1) is an original Modbus TCP/IP communication interface module engineered for the ABB AC800M Distributed Control System platform. In process-critical environments — oil & gas, power generation, chemical processing, pulp & paper, and water treatment — this module serves as the backbone of field device communication, enabling reliable data exchange between the AC800M controller and Modbus-compliant field instruments, drives, and third-party subsystems. Sourcing a verified original spare ensures your control architecture maintains its certified performance envelope without introducing compatibility risk during an unplanned outage.
When a CI867K01 fails in service, the downstream impact is immediate: loss of Modbus TCP polling cycles, blind spots in SCADA visibility, and potential process shutdown. Having a pre-tested, shelf-ready replacement on hand is the single most effective measure to compress mean time to repair (MTTR) and protect production continuity. Every unit dispatched from TOPNLMS undergoes functional verification prior to shipment and is covered by a 12-month warranty, giving maintenance teams the confidence to install and commission without hesitation.
| Parameter | Specification |
|---|---|
| Part Number | CI867K01 / 3BSE043660R1 |
| Manufacturer | ABB (Sweden) |
| Compatible Platform | ABB AC800M DCS (PM861, PM864, PM866, PM891 series controllers) |
| Communication Protocol | Modbus TCP/IP (IEEE 802.3 Ethernet) |
| Network Interface | RJ45, 10/100 Mbps |
| Max Modbus Connections | Up to 10 simultaneous TCP connections |
| Polling Rate | Configurable via Control Builder Plus |
| Power Supply | Supplied via AC800M backplane (no external PSU required) |
| Mounting | AC800M module rack (S800 I/O compatible backplane) |
| Operating Temperature | 0 °C to +55 °C |
| Storage Temperature | -40 °C to +70 °C |
| Humidity | 5–95% RH, non-condensing |
| Approvals | CE, UL, cUL |
| Country of Origin | Sweden |
| Warranty | 12 Months (TOPNLMS) |
| Condition | Original, new or refurbished-to-spec |
| Shipping | Worldwide; DHL / FedEx / UPS with tracking |
A CI867K01 replacement is rarely an isolated event. In a well-maintained AC800M control cabinet, the communication module sits within an ecosystem of interdependent components, and a failure in one area often signals latent stress in adjacent hardware. During any scheduled or corrective maintenance window involving the CI867K01, experienced maintenance engineers should simultaneously inspect the following components to prevent secondary failures and extend the operational life of the entire control system.
The AC800M processor module (such as the PM864A or PM866K01) shares the same backplane and power rail as the CI867K01. If the communication module has experienced voltage transients or thermal stress, the processor module’s firmware and memory integrity should be verified. Alongside this, the TB807 or TB840A termination unit and associated S800 I/O modules — including AI810, AO810, DI810, and DO810 — should be checked for loose field wiring and degraded terminal contacts, as Modbus polling errors are sometimes misdiagnosed as communication module faults when the root cause is a noisy field signal at the I/O layer.
The SD802F or SD803F power supply module feeding the AC800M rack is another critical inspection point. An aging power supply with marginal output voltage can cause intermittent module resets that mimic communication faults. Replacing a CI867K01 without verifying PSU health risks a repeat failure within weeks. Similarly, the CI854AK01 PROFIBUS DP interface module — often installed in the same rack for field device integration — should be inspected for firmware currency and connector integrity during the same maintenance window.
For sites running redundant Ethernet architectures, the CI867K01’s network patch cables and managed Ethernet switches (such as ABB’s recommended industrial switches or equivalent Hirschmann / Moxa units) should be tested for link quality and port negotiation. A degraded RJ45 connector or a switch port locked at 10 Mbps half-duplex can introduce latency that triggers Modbus timeout alarms even with a healthy module installed. Maintenance planners should also review the CI801 or CI810B FieldBus Communication Interface modules if the plant runs a mixed FOUNDATION Fieldbus and Modbus TCP topology, ensuring all communication paths are verified in a single outage window rather than requiring multiple planned shutdowns.
Finally, the AC800M battery backup unit (TU810V1 or equivalent) and the CF card or SD memory module used for controller program storage should be inspected and replaced on schedule. A failed battery results in program loss on power interruption, which can extend a simple module swap into a full system recovery event. Stocking these consumable components alongside the CI867K01 as a coordinated spare kit is a best practice that significantly reduces total downtime risk per maintenance event.
The CI867K01 was introduced as part of ABB’s AC800M platform expansion to address growing demand for open Ethernet-based communication in process automation. Many plants that originally commissioned AC800M systems in the mid-2000s are now operating hardware that is approaching or has exceeded its recommended service life. The CI867K01 remains the correct original replacement for these installations — it is fully backward compatible with all AC800M firmware versions and requires no hardware modification or reconfiguration of the Control Builder Plus project, making it the lowest-risk replacement path available.
For sites that have attempted to substitute third-party Modbus TCP gateways as a workaround, the CI867K01 restores native integration with the AC800M’s redundancy management, diagnostic reporting, and hot-standby switchover functions — capabilities that external gateways cannot replicate. This is particularly important in SIL-rated loops where communication integrity is part of the safety case. Restoring original hardware eliminates the need for a potentially costly safety re-validation of the modified architecture.
From a procurement standpoint, sourcing the CI867K01 through TOPNLMS provides access to verified original stock with full traceability documentation, pre-shipment functional testing, and a 12-month warranty — a combination that supports both the maintenance team’s technical requirements and the procurement department’s supplier qualification criteria. Lead times are confirmed at order placement, and expedited shipping is available for emergency breakdown situations.
Q1: Is the CI867K01 compatible with all AC800M controller versions?
Yes. The CI867K01 (3BSE043660R1) is compatible with all AC800M processor modules including PM861, PM864, PM864A, PM866, PM866K01, and PM891. It slots into any standard AC800M module rack position designated for communication interfaces and is recognized automatically by Control Builder Plus without requiring manual hardware configuration changes.
Q2: What pre-shipment testing is performed on each unit?
Every CI867K01 dispatched by TOPNLMS undergoes power-on functional verification, Ethernet link establishment testing, and visual inspection for connector and PCB integrity. Units that do not pass all test criteria are not shipped. A test report summary is available upon request for quality-assurance documentation purposes.
Q3: How long does delivery take, and what shipping options are available?
Standard international delivery via DHL or FedEx typically takes 3–7 business days depending on destination. Expedited next-flight-out options are available for emergency breakdown situations — contact [email protected] or call +86 18359293191 to confirm stock availability and arrange priority dispatch.
Q4: What does the 12-month warranty cover, and how is a warranty claim handled?
The 12-month warranty covers manufacturing defects and functional failure under normal operating conditions as specified in the ABB product datasheet. If a unit fails within the warranty period, TOPNLMS will arrange replacement or repair at no additional cost. Warranty claims are initiated by contacting [email protected] with the order reference and a brief description of the fault symptom. Return shipping instructions are provided within one business day.
Click Quote This Model and the Part Number field will auto-fill with CI867K01-3BSE043660R1.