BOSCH KM 3300-T 054915-103 Ruggedized DC Bus Capacitor Module
3300-TBOSCH Rexroth KM 3300-T 054915-103 KM3300 DC Bus Capacitor Module. Ruggedized for harsh industrial environments. In stock, tested, 12-month warranty. Fast shipping.
Request availability, condition, lead time and export shipping details for YBLX-JW2/11Z/3.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
In any automated production environment, the integrity of position sensing and travel control is foundational to system stability. The CHINT YBLX-JW2/11Z/3 rotary lever limit switch is a precision-engineered original spare part designed for demanding industrial applications — from conveyor line end-stop detection to machine tool axis positioning and crane travel limiting. Sourced directly from CHINT’s certified manufacturing chain, this unit ensures drop-in compatibility with existing YBLX-JW series installations, eliminating the risk of wiring modifications, bracket rework, or control logic adjustments during emergency replacements.
Unplanned downtime caused by a failed limit switch can cascade rapidly: a single faulty position signal can halt an entire production line, trigger PLC fault codes, or — in worst cases — cause mechanical overtravel damage to actuators and guide rails. Keeping a verified original YBLX-JW2/11Z/3 in your maintenance stockroom is one of the lowest-cost, highest-impact decisions a maintenance engineer can make. With a compact rotary lever actuator, IP67-rated enclosure, and a 1NO+1NC contact configuration, this switch covers the broadest range of replacement scenarios across CHINT-equipped control cabinets.
| Parameter | Specification |
|---|---|
| Model / SKU | YBLX-JW2/11Z/3 |
| Brand | CHINT (正泰) |
| Series | YBLX-JW2 / YBLX-JW Series |
| Product Type | Rotary Lever Travel / Limit Switch |
| Contact Configuration | 1NO + 1NC (1 Normally Open + 1 Normally Closed) |
| Rated Voltage | AC 380V / DC 220V |
| Rated Current | 5A |
| Actuator Type | Rotary Lever (Z-type, 3-position) |
| Enclosure Protection | IP67 (Dust-tight & Water-resistant) |
| Operating Temperature | -25°C to +70°C |
| Mounting | Standard panel / bracket mount, M4 screw fixing |
| Terminal Type | Screw terminal, compatible with 1.5–2.5mm² conductors |
| Mechanical Life | ≥ 10,000,000 operations |
| Electrical Life | ≥ 1,000,000 operations (rated load) |
| Country of Origin | China (CHINT Certified) |
| Compatibility | YBLX-JW series; direct replacement for YBLX-JW2/11Z/3 installations |
| Warranty | 12 Months (from date of shipment) |
| Application | Conveyor systems, machine tools, cranes, packaging lines, elevator travel control |
A limit switch failure rarely occurs in isolation. In most industrial control cabinets and field installations, the YBLX-JW2/11Z/3 operates as part of a broader position-sensing and interlock circuit. During scheduled maintenance shutdowns or corrective maintenance visits, experienced engineers know that replacing only the failed component without inspecting adjacent elements is a recipe for repeat callouts.
When servicing a machine or conveyor line that uses the YBLX-JW2/11Z/3, it is best practice to simultaneously inspect the CHINT NXC series AC contactors that receive the switch’s output signal — contact wear on these units is often accelerated by repeated inching operations triggered by limit switch cycling. Likewise, the CHINT NXR thermal overload relay protecting the drive motor should be checked for calibration drift, particularly in high-ambient-temperature environments.
The control wiring between the limit switch and the PLC input module deserves attention too. Loose or corroded terminals on CHINT ND series terminal blocks are a common source of intermittent faults that mimic limit switch failure. While the cabinet is open, verify the condition of the CHINT NDB2 series miniature circuit breakers on the control circuit — a weakened MCB can cause nuisance tripping that is misdiagnosed as a sensor fault.
For systems using a CHINT-compatible PLC or third-party controller, inspect the digital input (DI) module receiving the YBLX-JW2/11Z/3 signal. Burned or degraded input channels are frequently caused by voltage spikes from inductive loads — a signal isolator or surge suppressor module installed in series can extend both the switch and the I/O module’s service life significantly. If the installation uses a CHINT NXM series molded case circuit breaker as the main protection device for the machine circuit, verify its tripping characteristics have not drifted after years of service.
In conveyor and material handling applications, the encoder or proximity sensor working in tandem with the limit switch for redundant position confirmation should also be tested. Replacing the YBLX-JW2/11Z/3 while leaving a degraded proximity sensor in place simply shifts the failure point. Similarly, the CHINT NXQ2 series pushbutton station used for manual jog control of the same axis should be inspected for contact wear and seal integrity.
Finally, for installations in humid or dusty environments, check the condition of the cable glands and conduit seals at the limit switch entry point. A compromised seal allows moisture ingress that accelerates contact oxidation — the leading cause of premature limit switch failure in outdoor or wash-down environments.
The YBLX-JW2/11Z/3 is a direct original replacement for aging YBLX-JW series units installed across a wide range of legacy CHINT-equipped machines. Many facilities running equipment manufactured between 2005 and 2018 still rely on this series for travel limiting, and sourcing genuine original parts — rather than unverified substitutes — is critical to maintaining the original system’s safety interlock integrity.
Unlike generic aftermarket alternatives, the original CHINT YBLX-JW2/11Z/3 maintains the exact actuator geometry, contact gap, and switching differential specified in the original machine design. This means no bracket modifications, no rewiring, and no recalibration of PLC input thresholds — the replacement is mechanically and electrically transparent to the control system. For facilities managing a fleet of similar machines, standardizing on the YBLX-JW2/11Z/3 as the approved spare reduces procurement complexity and ensures technicians can complete replacements confidently without consulting engineering drawings each time.
For older systems where the original YBLX-JW2/11Z/3 mounting position has been modified or where a different actuator geometry is needed, TOPNLMS also stocks related YBLX-JW series variants to support cross-reference and upgrade scenarios. All units are tested prior to shipment and shipped with original CHINT packaging and documentation.
Q1: Is this an original CHINT part or an aftermarket substitute?
This is a genuine original CHINT YBLX-JW2/11Z/3 sourced through authorized supply channels. Each unit ships in original CHINT packaging with traceable batch documentation. We do not sell unbranded or OEM-substitute limit switches under CHINT model numbers.
Q2: What is the warranty coverage and what does it include?
All units carry a 12-month warranty from the date of shipment. The warranty covers manufacturing defects, contact failure under rated load conditions, and actuator mechanism faults. It does not cover damage caused by installation errors, overcurrent events beyond rated specifications, or physical impact. Warranty claims are processed with return shipping support.
Q3: How do I verify compatibility before installation?
Confirm the existing unit’s model label reads YBLX-JW2/11Z/3 or cross-reference the actuator type (rotary lever, Z-type, 3-position), contact configuration (1NO+1NC), and rated voltage (AC 380V / DC 220V). If your existing unit has a different suffix (e.g., /11Z/1 or /11H), contact us before ordering — we stock multiple YBLX-JW2 variants and can confirm the correct replacement.
Q4: What pre-shipment testing is performed?
Each YBLX-JW2/11Z/3 unit undergoes contact continuity verification, actuator travel and reset function testing, and insulation resistance check before dispatch. Units that do not meet CHINT’s published electrical and mechanical specifications are quarantined and not shipped. A test record is available upon request for quality-critical procurement.
Click Quote This Model and the Part Number field will auto-fill with YBLX-JW2/11Z/3.