Language English USD Currency
Call WhatsApp RFQ
Bussmann Industrial Automation Part

Bussmann 500NHG3B Original Industrial Spare NH Series Compatible

Request availability, condition, lead time and export shipping details for 500NHG3B.

Bussmann

500NHG3B

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part Number500NHG3B
CategoryPower Supply
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesIndustrial Spare NH Series
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Bussmann 500NHG3B Original Industrial Spare NH Series Compatible: Ensuring System Stability in Critical Power Distribution

The Bussmann 500NHG3B is an original NH Size 3 (NH3) fuse holder rated at 500A, engineered for demanding industrial power distribution environments. Whether you are managing a scheduled shutdown, responding to an unplanned trip, or building a strategic spare parts inventory for aging low-voltage switchgear, the 500NHG3B delivers the dimensional accuracy, contact reliability, and thermal performance that maintenance engineers depend on. Its DIN-rail compatible design ensures drop-in replacement compatibility with existing panel layouts, minimising re-wiring time and reducing total downtime per incident.

In modern manufacturing facilities, food processing plants, water treatment stations, and heavy industrial sites, the fuse holder is often the last component to receive attention during a preventive maintenance cycle — yet it is one of the most consequential. Oxidised contacts, cracked insulation bodies, or worn-out spring clips in a fuse holder can cause intermittent faults that are notoriously difficult to trace. Stocking a verified original Bussmann 500NHG3B eliminates this variable entirely and gives your maintenance team a reliable baseline for fault isolation.

Critical Technical Specs

Parameter Specification
Part Number / SKU 500NHG3B
Brand Bussmann (Eaton)
Series NH / DIN Fuse Holder Series
Fuse Size NH Size 3 (NH3)
Rated Current 500A
Rated Voltage Up to 690V AC
Poles 3-Pole
Mounting DIN Rail / Panel Mount
Compatible Fuse Links NH3 gG / gL / aR type fuse links
Insulation Material High-grade thermoplastic (UL94 V-0)
Contact Material Silver-plated copper alloy
Weight 360 g
Country of Origin Germany
Application Environment Industrial switchgear, MCC panels, power distribution boards
Maintenance Recommendation Inspect contacts every 12 months or after any fault event
Warranty 12 Months from date of shipment

Preventive Maintenance Strategy

A fuse holder replacement is rarely an isolated task. When a 500NHG3B is pulled from service for inspection or swap-out, experienced maintenance engineers treat it as a trigger for a broader panel health check. The incoming power section of any low-voltage distribution board contains multiple components that age at similar rates and share the same thermal and vibration stress cycles.

During the same maintenance window, it is best practice to inspect the NH3 fuse links (gG or gL type) seated in the holder — a degraded fuse link with a weakened element can pass continuity checks yet fail under load surge. Alongside this, the busbar connection terminals and DIN rail end stops should be checked for micro-arcing marks or loose torque, as these are common sources of thermal runaway in high-current circuits. If the panel includes a Bussmann or compatible 3-phase fuse monitoring relay, verify that its auxiliary contacts are still within specification, since these relays often share the same service life as the holder itself.

For panels feeding motor control centres, it is advisable to simultaneously inspect the contactor coils and overload relay modules downstream of the fuse protection stage. A fuse holder that has been operating near its thermal limit will often show signs of stress on adjacent components. Checking the cable lug crimps and insulated ferrules on the load-side conductors at this point adds minimal time but prevents a secondary fault within weeks of the primary repair.

Where the distribution board feeds a PLC or DCS control system, the 24VDC power supply module supplying the control rail should be load-tested during the same outage window. Voltage sags caused by a deteriorating fuse holder upstream can cause erratic PLC I/O behaviour that is misdiagnosed as a software or sensor fault. Similarly, any signal isolator modules or surge protection devices on the field wiring terminals should be visually inspected for discolouration or physical damage.

Finally, if the panel includes a residual current device (RCD) or earth leakage relay, a functional trip test should be performed before the panel is re-energised. This complete sweep — fuse holder, fuse links, busbars, contactors, power supplies, signal isolators, and protection relays — transforms a single-component replacement into a documented preventive maintenance event that extends the reliable service life of the entire control cabinet.

Strategic Replacement Solutions

The Bussmann 500NHG3B is a direct replacement for earlier NH3 fuse holder variants used in legacy switchgear assemblies manufactured from the 1990s onward. Many industrial sites still operate distribution boards that were designed around the original Bussmann NH series dimensional standard, and sourcing a non-original or dimensionally inconsistent replacement introduces contact resistance variability that can void panel certifications and create latent safety risks.

Using an original 500NHG3B preserves the original panel certification footprint, maintains the rated 500A continuous current capacity without derating, and ensures that the fuse link ejection mechanism operates correctly — a critical safety feature during a fault event. For maintenance teams managing multiple sites or operating under IEC 60269 compliance requirements, standardising on the original Bussmann part number eliminates the approval overhead associated with alternative sourcing.

From a procurement standpoint, holding a minimum of one spare 500NHG3B per distribution board in your site inventory is a low-cost insurance policy against extended lead times. Critical production lines that cannot tolerate more than two hours of unplanned downtime should consider a two-unit buffer stock, particularly if the nearest authorised distributor is more than same-day delivery distance away.

Support FAQ

Q1: Is the 500NHG3B compatible with all NH Size 3 fuse links?
Yes. The 500NHG3B is designed to accept standard NH3 fuse links conforming to IEC 60269-1, including gG, gL, and aR types from major manufacturers. Always verify the fuse link’s rated current does not exceed 500A and that the voltage rating matches your system.

Q2: How is the unit tested before shipment?
Each 500NHG3B unit undergoes a visual inspection for contact integrity, insulation body condition, and mechanical operation of the fuse clip mechanism before dispatch. Units are individually packaged to prevent transit damage. A test report is available upon request for critical infrastructure orders.

Q3: What does the 12-month warranty cover?
The 12-month warranty covers manufacturing defects, contact failure under normal operating conditions, and insulation body integrity. It does not cover damage resulting from installation errors, overcurrent events beyond the rated 500A, or environmental exposure outside the specified operating range. Warranty claims are processed within 5 business days of receipt of the returned unit.

Q4: Can I use this part to replace a fuse holder in a legacy panel without re-certification?
In most jurisdictions, replacing a like-for-like original part (same manufacturer, same part number, same ratings) does not trigger a re-certification requirement under IEC or CE frameworks. However, you should always consult your local electrical safety authority and your panel’s original documentation before making this determination for safety-critical installations.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with 500NHG3B.