BOSCH KM 3300-T 054915-103 Ruggedized DC Bus Capacitor Module
3300-TBOSCH Rexroth KM 3300-T 054915-103 KM3300 DC Bus Capacitor Module. Ruggedized for harsh industrial environments. In stock, tested, 12-month warranty. Fast shipping.
Request availability, condition, lead time and export shipping details for E1667.211.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
When a safety monitoring module fails or reaches end-of-life in a certified functional safety architecture, every hour of unplanned downtime carries both operational and compliance risk. The Braun E1667.211 is a SIL3-rated safety monitoring module certified to IEC 61508, designed for deployment in safety instrumented systems (SIS), emergency shutdown systems (ESD), and process safety applications across oil & gas, chemical, power generation, and heavy manufacturing environments.
At TOPNLMS, we specialize in sourcing, testing, and supplying hard-to-find and discontinued safety-critical components. Whether you are executing a like-for-like replacement of a failed E1667.211, planning a phased upgrade of an aging Braun safety relay panel, or integrating this module into a modernized safety PLC architecture, our team provides the technical support and procurement assurance your project demands.
| Parameter | Braun E1667.211 (This Unit) | Typical Legacy / Predecessor Models | Replacement Notes |
|---|---|---|---|
| Safety Integrity Level | SIL3 (IEC 61508) | SIL2 / SIL3 variants | Verify SIL rating matches your SIS loop requirement |
| Certification Standard | IEC 61508 Ed.2 | IEC 61508 Ed.1 / EN 954-1 | Ed.2 certification is backward compatible for most SIS designs |
| Mounting / Form Factor | DIN rail, 22.5 mm width | DIN rail, 22.5–45 mm | Confirm rail slot width in existing control cabinet |
| Supply Voltage | 24 V DC (nominal) | 24 V DC / 115–230 V AC variants | Match supply voltage; use a 24 V DC PSU module if upgrading from AC-powered predecessor |
| Output Contacts | Safety relay output (NO/NC) | Safety relay / solid-state output | Verify wiring polarity and contact rating before reconnection |
| Input Channel Type | Dual-channel monitored input | Single / dual channel | Dual-channel wiring must be preserved; do not simplify to single-channel |
| Communication Interface | Standalone (hardwired SIS) | Standalone / fieldbus optional | No fieldbus reconfiguration required for hardwired SIS replacement |
| Response Time | < 20 ms (typical) | 15–30 ms | Confirm response time meets your SIL loop PFD/PFH calculation |
| Operating Temperature | -25 °C to +55 °C | 0 °C to +55 °C (older models) | Extended range suitable for outdoor or unheated cabinet installations |
| Warranty (TOPNLMS Supply) | 12-Month Warranty — covers functional failure under normal operating conditions. Replacement or refund within warranty period. | ||
A successful E1667.211 replacement rarely involves a single component in isolation. In practice, field engineers undertaking a safety system retrofit or emergency replacement will encounter a cluster of interdependent components that must be evaluated simultaneously to ensure the upgraded SIS loop remains IEC 61508 compliant and operationally stable.
In many Braun safety relay panels, the E1667.211 is installed alongside Braun E1667.210 or E1667.212 companion modules that handle complementary monitoring functions such as standstill detection or speed monitoring. When replacing the E1667.211, it is prudent to inspect these adjacent modules for wear, since they share the same DIN rail segment, power bus, and wiring harness. A failure in one module often indicates thermal or electrical stress that may have affected neighboring units.
The 24 V DC supply feeding the E1667.211 typically originates from a dedicated safety-rated power supply module — commonly a unit such as a Puls PIANO or Phoenix Contact QUINT series PSU — which provides redundant output and diagnostic signaling. If the power supply has not been replaced within its recommended service interval, a concurrent PSU replacement during the E1667.211 swap eliminates a common root cause of repeat failures.
For installations where the E1667.211 interfaces with a safety PLC — such as a Siemens S7-300 F-CPU (e.g., CPU 315F-2 PN/DP) or a Pilz PSS 4000 safety controller — the hardwired I/O connections between the module’s relay output and the F-DI input card must be verified against the original safety validation documentation. Any change in cable routing, terminal assignment, or contact configuration requires a partial re-validation of the SIS loop under IEC 61511.
Where the existing cabinet uses Phoenix Contact or Weidmüller terminal blocks for the dual-channel input wiring, engineers should inspect terminal torque and insulation condition before reconnecting to the new E1667.211. Loose or degraded terminals are a frequent source of nuisance trips after module replacement. In some retrofit projects, replacing the terminal block row adjacent to the safety module — using Phoenix Contact PTFIX or UT series terminals — is included as a standard practice to ensure long-term connection integrity.
If the safety system includes a Braun or third-party HMI panel for operator acknowledgment of safety trips, the reset logic wired to the E1667.211’s manual reset input should be tested end-to-end after installation. This is particularly important in systems where the HMI communicates via PROFIBUS DP or PROFINET to a supervisory PLC, as the safety relay’s hardwired reset circuit operates independently of the fieldbus and must be validated separately.
For facilities managing a broader Braun safety relay inventory — including E1667.200, E1667.201, E1667.220, or other series variants covering emergency stop, two-hand control, light curtain, and door interlock monitoring — TOPNLMS maintains stock across the E1667 product family. Consolidating your safety relay procurement through a single supplier simplifies traceability, warranty management, and spare parts documentation for your functional safety management system (FSMS).
Q: Can I replace the E1667.211 without re-validating the entire SIS loop?
A: A like-for-like replacement with an identical E1667.211 unit — same part number, same firmware revision where applicable — is generally treated as a maintenance replacement and does not trigger full re-validation under IEC 61511. However, your site’s Management of Change (MOC) procedure and the original safety case documentation should be consulted. If the replacement unit has a different hardware revision, a partial re-validation of the affected SIS loop is recommended.
Q: The original E1667.211 was wired for dual-channel input. Does the replacement unit support the same wiring configuration?
A: Yes. The E1667.211 is designed for dual-channel monitored input, and the terminal layout is consistent across production batches. Retain the original wiring diagram and reconnect terminals in the same sequence. Do not simplify to a single-channel configuration, as this would reduce the achieved SIL level of the loop.
Q: What is the correct procedure for testing the replacement module before returning the SIS to service?
A: After installation, perform a functional proof test of the complete SIS loop: simulate the hazardous condition (e.g., open the E-stop circuit or interrupt the safety sensor signal), verify that the E1667.211 de-energizes its output relay within the specified response time, confirm that the downstream actuator (valve, contactor, or drive) responds correctly, then perform a manual reset and verify the system returns to the run state. Document the test results in your proof test record as required by IEC 61511-1 Clause 16.
Q: The cabinet has limited space. Will the E1667.211 fit in the same slot as the failed unit?
A: The E1667.211 uses a standard 22.5 mm DIN rail footprint. If the original unit occupied the same form factor, the replacement is a direct physical fit. No additional rail space or cabinet modification is required. Confirm that the DIN rail clip is undamaged before mounting the new unit.
Q: Can the E1667.211 be used in a PROFIBUS or PROFINET-integrated safety system?
A: The E1667.211 operates as a hardwired safety relay and does not have a native fieldbus interface. It integrates into PROFIBUS or PROFINET architectures via hardwired I/O connections to the F-DI/F-DO cards of the safety PLC. No fieldbus configuration changes are required when replacing the module.
Q: What if the E1667.211 is no longer in production? Can TOPNLMS still supply it?
A: Yes. TOPNLMS specializes in sourcing discontinued and hard-to-find industrial safety components. Each unit supplied is inspected and function-tested prior to shipment. If the E1667.211 is confirmed end-of-life by the OEM, we can also advise on qualified upgrade paths to current-generation safety monitoring modules that meet or exceed the original SIL3 / IEC 61508 specification.
Every Braun E1667.211 supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. Our pre-shipment inspection process includes visual examination, terminal integrity check, and functional power-on testing to verify that the module operates within its specified parameters before it leaves our facility in Xiamen.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund within the warranty period, subject to confirmation that the failure occurred under normal operating conditions consistent with the module’s rated specifications. Our after-sales response target is 24 hours for initial acknowledgment and 5 business days for resolution.
For procurement teams managing safety-critical spare parts inventories, TOPNLMS can provide a test report, packing list, and commercial invoice with full traceability documentation to support your incoming inspection and FSMS records. Bulk orders and standing purchase agreements for the E1667 series are available upon request.
Contact our technical sales team to confirm stock availability, lead time, and shipping options to your facility.
Click Quote This Model and the Part Number field will auto-fill with E1667.211.