Language English USD Currency
Call WhatsApp RFQ
Bently Nevada Industrial Automation Part

Bently Nevada 330130-080-03-05 Replacement for 3300 XL

Request availability, condition, lead time and export shipping details for 330130-080-03-05.

Bently Nevada

330130-080-03-05

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part Number330130-080-03-05
ConditionAvailability Check
Lead TimeRFQ Confirmation
Series3301
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Bently Nevada 330130-080-03-05 Replacement for 3300 XL: Smooth Transition from Legacy Vibration Monitoring Systems

The Bently Nevada 330130-080-03-05 is an 8-meter proximity transducer extension cable engineered for the 3300 XL series vibration monitoring system. For facilities operating aging condition monitoring infrastructure — including legacy 3300 NSv monitors, obsolete 7200 series proximitors, or discontinued Bently Nevada 3500 rack-based systems — this cable provides a verified, drop-in replacement path that eliminates the need for full system overhaul. Whether your plant is migrating from an older 3300/16 monitor to the current 3300 XL platform, or simply replacing a degraded cable in an existing installation, the 330130-080-03-05 delivers the electrical and mechanical compatibility required for uninterrupted shaft vibration and position measurement.

The cable interfaces directly with the Bently Nevada 330100 series proximity transducers — including the 330101, 330103, and 330105 variants — and is fully compatible with the 330180 proximitor/extension cable driver modules. The 8-meter total length suits the majority of turbine, compressor, and pump installations where the transducer-to-monitor distance falls within standard machinery train layouts. For installations requiring shorter or longer runs, the 330130 series is available in multiple length configurations; the 330130-080-03-05 specifically addresses the 8-meter requirement with a 3-meter armored extension and 5-meter interconnect geometry.

Compatibility Comparison Table

Parameter Legacy / Replaced Model 330130-080-03-05 (This Unit)
Compatible Monitor Series 3300 NSv, 3300/16, 7200 Series 3300 XL (primary); backward-compatible with 3300 NSv
Transducer Interface 330100 / 330101 / 330103 330100 / 330101 / 330103 / 330105
Cable Total Length Various (5m, 9m legacy configs) 8m total (3m armored + 5m interconnect)
Connector Type MIL-spec coaxial, 2-pin MIL-spec coaxial, 2-pin (direct swap)
Signal Type Eddy-current, −24 VDC bias Eddy-current, −24 VDC bias (unchanged)
Wiring Change Required — None — direct pin-for-pin replacement
Installation Space Standard conduit / cable tray Identical OD; fits existing conduit runs
Communication Protocol Analog (mV/mil, mV/µm) Analog (mV/mil, mV/µm) — no protocol change
Rack / Chassis Compatibility 3500 rack, 3300 rack 3300 XL rack; 3500 rack (with 330180 driver)
Replacement Recommendation Immediate for degraded or aged cables Direct replacement; no recalibration required
Warranty — 12-Month Warranty (TOPNLMS)

Seamless Upgrade Solutions

A successful migration from a legacy vibration monitoring architecture to the 3300 XL platform rarely involves a single component. In practice, field engineers replacing a degraded 330130-080-03-05 extension cable will often simultaneously audit adjacent components in the same machinery train. The 330100-90-00 proximity transducer — the standard 5mm eddy-current probe paired with this cable — is a frequent co-replacement item, particularly when the transducer tip shows wear or the gap voltage has drifted outside the −10 VDC to −18 VDC linear range. Similarly, the 330180-51-05 proximitor/extension driver module, mounted in the field junction box, should be inspected for corrosion or connector fatigue whenever the extension cable is changed.

For plants upgrading from the older 3300/16 monitor cards to the current 3300 XL 16-channel vibration monitor, the 330130-080-03-05 cable is fully compatible with the new monitor’s input terminals, eliminating any need to re-pull cable through conduit. The 3300 XL monitor accepts the same −24 VDC proximitor supply and analog output scaling as its predecessor, meaning existing DCS analog input cards — such as those in a Honeywell TDC 3000 or Emerson DeltaV I/O subsystem — require no rescaling or re-ranging at the controller level.

Where plants are also upgrading their machinery protection relay logic, the Bently Nevada 3500/42M position monitor and 3500/45 position monitor are common companion upgrades that share the same rack infrastructure and wiring conventions as the 3300 XL system. In turbine control cabinet retrofits, the 330130-080-03-05 is frequently installed alongside updated terminal blocks and signal conditioners. The Bently Nevada 3500/20 rack power supply module and 3500/22M transient data interface are often refreshed in the same outage window to ensure the entire signal chain — from transducer tip through extension cable, proximitor, monitor card, and rack backplane — is operating within current factory specifications. For sites using Modbus RTU or FOUNDATION Fieldbus communication from the 3300 XL system to the plant DCS, no changes to the communication module configuration are required when only the extension cable is replaced.

Procurement teams sourcing this cable as part of a broader MRO initiative will find that TOPNLMS maintains stock of the full 330130 series in multiple length variants, as well as the 330100 transducer family and 330180 driver modules, enabling single-source procurement for the complete eddy-current measurement chain.

Retrofit Guidance FAQ

Q: Do I need to recalibrate the system after replacing the extension cable?
A: No. The 330130-080-03-05 is a direct electrical replacement. Provided the new cable length matches the original (8m total), the system scale factor and gap voltage remain within specification. A gap voltage verification check at the proximitor output is recommended as a commissioning step but is not a full recalibration.

Q: Is the wiring pinout identical to the cable I am replacing?
A: Yes. The MIL-spec coaxial connector pinout is standardized across the 330130 series. The center conductor carries the −24 VDC bias and eddy-current signal; the shield is grounded at the monitor end only. No wiring changes are required at the junction box or monitor terminal strip.

Q: Can this cable be used with a 3500 series monitor instead of the 3300 XL?
A: Yes, with the appropriate 330180 series proximitor/driver module. The 330130-080-03-05 is electrically compatible with the 3500 rack system when the correct driver is installed. Confirm the driver part number against the 3500 system documentation before installation.

Q: What is the maximum conduit bend radius for installation?
A: The armored extension section has a minimum bend radius of approximately 50mm. The interconnect cable section is more flexible. Avoid sharp bends within 300mm of either connector to prevent signal degradation.

Q: Will replacing only the extension cable resolve a high-noise or erratic vibration reading?
A: Possibly. Extension cable degradation — including shield continuity loss, connector corrosion, or jacket cracking — is a common source of noise in eddy-current measurement chains. If replacing the cable does not resolve the issue, the 330100 series transducer and 330180 proximitor should be tested next.

Q: Is this cable compatible with both radial vibration and axial position measurement channels?
A: Yes. The 330130-080-03-05 is a passive coaxial cable and is application-agnostic within the eddy-current measurement system. It is equally suitable for radial vibration, axial position, and differential expansion measurement channels on the 3300 XL and 3500 platforms.

Q: What communication protocols are supported by the 3300 XL system this cable feeds into?
A: The 3300 XL monitor supports analog 4–20 mA output, relay contact outputs, and — depending on the communication option card installed — Modbus RTU serial communication. The extension cable itself is protocol-agnostic; it carries the raw analog eddy-current signal from the transducer to the proximitor driver, upstream of any digital communication layer.

Warranty Assurance

Every 330130-080-03-05 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to dispatch, each cable assembly undergoes continuity testing, insulation resistance verification, and connector integrity inspection to confirm it meets the original Bently Nevada specification. Units that do not pass pre-shipment testing are quarantined and not offered for sale.

In the event of a confirmed defect within the warranty period, TOPNLMS will arrange replacement or credit at no additional cost to the buyer. Our after-sales response target is one business day for warranty claims submitted by email. Expedited replacement shipments are available for critical plant applications where downtime cost is a primary concern.

Stock is maintained in Xiamen, China, with standard international shipping via DHL, FedEx, or UPS. Lead time for in-stock units is typically 3–5 business days to most destinations. For urgent requirements, same-day dispatch is available for orders confirmed before 14:00 CST. Buyers requiring material test reports, certificate of conformance, or customs documentation should specify these requirements at the time of order.

TOPNLMS supplies industrial automation and control system components to maintenance teams, MRO procurement departments, and system integrators globally. Our inventory focus on Bently Nevada, Emerson, Honeywell, ABB, and Siemens condition monitoring and process control hardware means that companion components for your 3300 XL migration project are typically available from a single source, reducing procurement lead time and simplifying logistics.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with 330130-080-03-05.