Bently Nevada 190501-20-00-CN Velomitor CT Upgrade Solution
190501-20-00-CNDrop-in replacement for Bently Nevada 190501-20-00-CN Velomitor CT velocity transducer. Compatible wiring, 4-20mA output, 12-month warranty. Fast global shipping.
Request availability, condition, lead time and export shipping details for 190501-19-00-00.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Bently Nevada 190501-19-00-00 Velomitor CT Velocity Transducer is a precision-engineered original spare part designed for continuous vibration monitoring in critical industrial rotating machinery. In high-availability plant environments — petrochemical, power generation, pulp and paper, offshore platforms, and heavy manufacturing — unplanned downtime caused by a failed velocity transducer can cost tens of thousands of dollars per hour. Stocking a verified original 190501-19-00-00 is one of the most cost-effective decisions a maintenance team can make.
The Velomitor CT series is purpose-built for seismic and casing vibration measurement on turbines, compressors, pumps, motors, and gearboxes. Its wide frequency response, rugged stainless-steel housing, and direct compatibility with Bently Nevada 3500 Series and System 1 monitoring platforms make it a trusted choice for both OEM installations and field replacements. When a transducer fails during a scheduled outage or an emergency shutdown, having a pre-tested 190501-19-00-00 on the shelf means the machine is back online in minutes, not days.
| Parameter | Specification |
|---|---|
| Part Number / SKU | 190501-19-00-00 |
| Brand | Bently Nevada |
| Series | Velomitor CT |
| Product Type | Velocity Transducer (Seismic / Casing Vibration) |
| Measurement Type | Velocity (mm/s or in/s) |
| Frequency Response | Approx. 2 Hz – 1,000 Hz (±3 dB) |
| Sensitivity | Approx. 100 mV/in/s (4 mV/mm/s) |
| Output Signal | Analog voltage, 2-wire |
| Supply Voltage | 18–30 VDC (loop powered) |
| Operating Temperature | -40°C to +121°C (-40°F to +250°F) |
| Housing Material | 316 Stainless Steel |
| Connector Type | 2-pin MIL-C-5015 style |
| Mounting | 1/4-28 UNF threaded stud |
| Compatible Systems | Bently Nevada 3500 Series, System 1, 3300 Series monitors |
| Application | Turbines, compressors, pumps, motors, gearboxes |
| Ingress Protection | IP67 (dust-tight, water-immersion resistant) |
| Origin | USA (Original Bently Nevada) |
| Condition | Original / New Old Stock |
| Warranty | 12 Months from date of shipment |
A velocity transducer replacement is rarely an isolated event. When a 190501-19-00-00 is flagged for replacement during a scheduled outage or a condition-monitoring alarm, experienced maintenance engineers use the opportunity to audit the entire vibration monitoring loop and the surrounding control cabinet. This approach minimizes repeat shutdowns and extends the operational life of the monitoring system.
Begin with the transducer cable assembly. The Bently Nevada 330130 series interconnect cables and 330180 series extension cables are the most common wear items in a Velomitor CT installation. Connector corrosion, jacket cracking from heat cycling, and shield continuity failures are frequent root causes of false alarms that are misdiagnosed as transducer faults. Inspect and replace cables at the same interval as the transducer.
Next, verify the condition of the 3500/42M Proximitor/Seismic Monitor module in the 3500 rack. This I/O module processes the velocity signal from the 190501-19-00-00 and feeds it to the System 1 software. A degraded input channel can mask a genuine machinery fault or generate nuisance trips. If the module has been in service for more than five years without calibration verification, schedule a bench test or swap it with a spare 3500/42M during the same outage window.
The 3500 rack power supply module — typically the 3500/15 Power Supply — should also be inspected. Voltage ripple or marginal output on the 24 VDC rail directly affects transducer bias voltage and signal quality. A failing power supply is a common but overlooked cause of intermittent vibration readings. Stocking a spare 3500/15 alongside the 190501-19-00-00 is a best practice for any facility running multiple 3500 racks.
For facilities using the 3500/20 Rack Interface Module for Modbus or Ethernet communication to the DCS or SCADA layer, confirm that firmware is current and that the communication module is not generating CRC errors. A communication fault at this level can prevent alarm annunciation even when the transducer is functioning correctly.
During the cabinet inspection, check the terminal blocks and DIN rail assemblies that terminate the transducer field wiring. Loose terminations on Phoenix Contact or Weidmüller-style terminal blocks are a leading cause of intermittent signal loss. Torque all terminals to specification and apply anti-vibration locking compound where appropriate.
If the machine being monitored is a steam or gas turbine, also review the condition of the Bently Nevada 3300 XL 8mm proximity probe system used for shaft relative vibration. The 190501-19-00-00 measures casing velocity; the proximity probes measure shaft displacement. Both datasets are required for a complete vibration signature. Probes, extension cables, and Proximitor sensors in the 3300/16 series should be on the same replacement schedule.
Finally, for facilities transitioning to predictive maintenance programs, consider pairing the 190501-19-00-00 with a portable data collector such as the CSI 2140 or equivalent to establish baseline velocity signatures immediately after installation. This baseline becomes the reference for future trend analysis and early fault detection, maximizing the return on your spare parts investment.
The 190501-19-00-00 is a direct replacement for earlier Bently Nevada Velomitor CT variants and is backward-compatible with all 3500 Series and 3300 Series monitor racks without firmware changes or reconfiguration. This plug-and-play compatibility is critical in legacy plant environments where the control system cannot be modified without a formal management-of-change process.
For facilities that originally installed the older 190501-00-00-00 or 190501-01-00-00 variants, the 190501-19-00-00 is the current production equivalent and offers improved EMI shielding and connector sealing. The mechanical footprint, mounting thread, and electrical interface are identical, ensuring zero-modification installation.
In plants where the original Bently Nevada monitoring system is being maintained alongside a newer DCS platform, the 190501-19-00-00 provides a cost-effective path to extend the life of the existing vibration monitoring infrastructure without a full system upgrade. This is particularly valuable in facilities where a 3500 rack replacement would require re-engineering of the entire machinery protection philosophy — a project that can take 12–24 months and cost significantly more than maintaining the existing hardware with original spare parts.
Each 190501-19-00-00 shipped from TOPNLMS is functionally tested prior to dispatch, packaged in anti-static and moisture-barrier materials, and accompanied by a test report. Lead time is typically 1–3 business days for in-stock units, with express shipping options available for emergency shutdowns.
Q1: Is the 190501-19-00-00 a genuine original Bently Nevada part or an aftermarket equivalent?
The 190501-19-00-00 supplied by TOPNLMS is an original Bently Nevada Velomitor CT velocity transducer — not a copy, clone, or third-party equivalent. Each unit is sourced through verified industrial supply channels and is functionally tested before shipment. A 12-month warranty from the date of shipment is included with every unit.
Q2: How do I verify compatibility with my existing 3500 Series monitoring rack before installation?
The 190501-19-00-00 is compatible with all Bently Nevada 3500/42M Proximitor/Seismic Monitor modules and 3500/42 Seismic Monitor modules without any hardware or firmware modification. Confirm your rack accepts a 2-wire, loop-powered velocity input on the relevant channel. If you require a compatibility confirmation for a specific rack configuration, contact our technical team at [email protected] with your rack part number and channel assignment.
Q3: What is included in the pre-shipment testing process?
Each 190501-19-00-00 undergoes functional verification of output sensitivity, frequency response at reference frequencies, bias voltage compliance, and connector integrity before packaging. Units that do not meet Bently Nevada factory specifications are quarantined and not shipped. A test record is available upon request.
Q4: What is the recommended inventory strategy for facilities running multiple Velomitor CT installations?
For facilities with 5 or more 190501-19-00-00 units installed, we recommend maintaining a minimum of 10% on-hand spare ratio — typically 1 spare per 10 installed units, with a minimum of 2 spares regardless of installation count. For critical machinery (turbines, main compressors, boiler feed pumps), a dedicated hot-spare per machine train is best practice. Bulk procurement of 5+ units qualifies for priority lead time and volume pricing — contact [email protected] for a quotation.
Click Quote This Model and the Part Number field will auto-fill with 190501-19-00-00.