Bently Nevada 190501-21-00-CN Original Industrial Velomitor CT
190501-21-00-CNBently Nevada 190501-21-00-CN Velomitor CT piezoelectric velocity transducer. Original spare, Velomitor CT series compatible. 12-month warranty. Fast global shipping.
Request availability, condition, lead time and export shipping details for 190501-07-00-CN.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Bently Nevada 190501-07-00-CN Velomitor CT Seismic Velocity Transducer is a precision OEM spare part engineered for continuous vibration monitoring on rotating machinery in demanding industrial environments. Whether you are managing a planned shutdown, responding to an unplanned trip, or executing a preventive maintenance cycle, having a verified original 190501-07-00-CN in your spare parts inventory is a direct investment in system uptime and operational continuity.
Rotating machinery — including steam turbines, gas compressors, centrifugal pumps, and large induction motors — depends on accurate seismic velocity measurement to detect imbalance, misalignment, bearing wear, and structural resonance before these conditions escalate into catastrophic failure. The Velomitor CT sensor delivers a broadband velocity output that integrates directly with Bently Nevada 3500 Series rack-based monitoring systems, System 1 condition monitoring software, and compatible third-party vibration monitoring platforms. Replacing a degraded or failed sensor with a genuine 190501-07-00-CN ensures measurement continuity without recalibration delays or compatibility compromises.
Facilities operating legacy Bently Nevada monitoring infrastructure — including older 7200 Series and 3300 Series racks — frequently source the 190501-07-00-CN as a cross-compatible velocity input where the original sensor type has been discontinued. This makes the Velomitor CT a strategically important component for extending the service life of installed monitoring systems without requiring a full rack upgrade.
| Parameter | Specification |
|---|---|
| Part Number | 190501-07-00-CN |
| Brand | Bently Nevada (Baker Hughes) |
| Series | Velomitor CT |
| Sensor Type | Seismic Velocity Transducer (Piezoelectric) |
| Measurement Range | 0.5 – 1000 Hz (typical broadband) |
| Output Signal | Velocity (mV/mm/s or mV/in/s) |
| Operating Temperature | -40°C to +121°C (-40°F to +250°F) |
| Ingress Protection | IP67 (dust-tight, immersion-resistant) |
| Connector Type | 2-pin MIL-C-5015 style (CN suffix) |
| Cable Compatibility | Bently Nevada 330130 / 330180 series extension cables |
| Mounting | Stud mount, ¼-28 UNF or M8 thread (adapter available) |
| Compatible Systems | Bently Nevada 3500 Series, System 1, 7200 Series, 3300 Series |
| Application | Turbines, compressors, pumps, motors, gearboxes |
| Origin | USA (OEM) |
| Condition | Original, new or recertified stock |
| Pre-shipment Testing | Full functional and electrical verification |
| Warranty | 12 Months |
A seismic velocity sensor replacement should never be treated as an isolated task. When a 190501-07-00-CN is pulled from service — whether due to signal drift, connector corrosion, or physical damage — the surrounding monitoring loop deserves a systematic inspection. Maintenance teams that treat sensor replacement as a trigger for a broader loop audit consistently achieve lower mean-time-to-repair and fewer repeat failures.
Begin with the Bently Nevada 330130 or 330180 series extension cables. These cables are the most common source of intermittent velocity signal faults and are frequently overlooked during sensor-focused troubleshooting. Inspect the full cable run for chafing, connector pin corrosion, and shield continuity. A degraded cable will compromise even a brand-new 190501-07-00-CN within weeks of installation.
Next, verify the condition of the Bently Nevada 3500/42M Velocity Monitor module or equivalent rack card receiving the sensor signal. Module input impedance drift and internal relay contact wear are common in systems that have operated continuously for more than five years. If the 3500 rack is also approaching end-of-life, consider sourcing a spare 3500/20 Rack Interface Module and 3500/15 Power Supply to ensure the entire monitoring chain remains serviceable.
For facilities running parallel proximity probe-based displacement monitoring alongside velocity sensors, inspect the associated Bently Nevada 3300 XL 8mm or 11mm proximity probes and their 3300 series extension cables and drivers. Displacement and velocity channels are often wired into the same control cabinet terminal strip, and a cabinet inspection that covers both sensor types is far more efficient than two separate work orders.
The terminal blocks and DIN rail assemblies inside the monitoring cabinet should also be checked during any sensor replacement outage. Loose terminations on signal wiring are a leading cause of false alarms and nuisance trips that erode operator confidence in the monitoring system. Phoenix Contact or Weidmüller-compatible terminal blocks rated for low-level signal circuits are the appropriate replacement standard.
If the plant uses a Bently Nevada TDXnet or System 1 data acquisition node for remote condition monitoring, confirm that the node firmware is current and that the channel configuration correctly reflects the 190501-07-00-CN sensitivity value. An incorrect sensitivity entry in the software will produce systematic measurement error that is difficult to diagnose without comparing raw sensor output against a calibrated reference.
Finally, for rotating equipment in hazardous area classifications, verify that the Bently Nevada 3500/33 16-channel relay module or equivalent safety relay output is correctly configured for the velocity alarm setpoints appropriate to the machine class. Alarm setpoints that were set during initial commissioning may no longer reflect the machine’s current condition baseline after years of wear.
The 190501-07-00-CN is the preferred direct replacement for earlier Bently Nevada velocity sensor variants used in the same Velomitor CT family. Facilities that previously operated the 190501-01-00-CN or 190501-03-00-CN variants can typically substitute the -07-00-CN revision without rack reconfiguration, as the output sensitivity and connector interface are maintained across the revision series. This backward compatibility is a significant advantage for plants that need to standardize their spare parts inventory across multiple machine trains with different installation dates.
For older installations where the original sensor was a non-Velomitor velocity pickup (such as an IRD or Wilcoxon equivalent), the 190501-07-00-CN provides a direct upgrade path with improved temperature range, better EMI rejection, and a more robust connector design. The transition requires only a sensitivity value update in the monitoring system software — no mechanical modifications to the sensor mounting pad are necessary in most cases.
Maintaining a minimum of two 190501-07-00-CN units in on-site spare stock is recommended for any facility operating more than four monitored machine trains. The sensor’s role as a primary trip input on critical rotating equipment means that a zero-stock situation during an unplanned outage can extend downtime by days if the part must be sourced and shipped under emergency conditions. Stocking two units provides immediate swap capability while a replacement order is placed, and the 12-month warranty on each unit ensures that shelf stock remains covered during normal inventory rotation cycles.
Q1: Is the 190501-07-00-CN compatible with my existing Bently Nevada 3500 Series rack?
Yes. The Velomitor CT 190501-07-00-CN is designed for direct integration with the Bently Nevada 3500/42M Velocity Monitor and other 3500 Series velocity input modules. The -CN suffix denotes the connector variant; confirm your existing cable connector type before ordering. No rack reconfiguration is required when replacing a same-series sensor.
Q2: What pre-shipment testing is performed on each unit?
Every 190501-07-00-CN shipped from our inventory undergoes full functional verification including output sensitivity check, insulation resistance test, and connector integrity inspection. A test report is available upon request. Units are shipped in anti-static packaging with protective connector caps installed.
Q3: What does the 12-month warranty cover?
The 12-month warranty covers manufacturing defects, electrical failure under normal operating conditions, and connector integrity. It does not cover damage resulting from incorrect installation, overvoltage, or mechanical impact. Warranty claims are processed within 5 business days of receipt of the returned unit.
Q4: How do I verify compatibility before installation?
Record the existing sensor part number from the nameplate and compare it against the 190501-07-00-CN datasheet sensitivity value (typically expressed in mV/mm/s). Confirm the connector type matches your extension cable. If you are replacing a non-Bently Nevada sensor, provide us with the original sensor datasheet and we will confirm compatibility before shipment.
Click Quote This Model and the Part Number field will auto-fill with 190501-07-00-CN.