Product Overview
BEARING CDX-HS/A 70/07 Ruggedized Pump Module for Harsh Environments
The BEARING CDX-HS/A 70/07 (SKU: HP+/V-0010-02170-EN-0020-85925-CDXHS-A-70-07) is a professional-grade, single-stage centrifugal pump engineered for continuous, reliable operation in the most demanding industrial environments. Designed under BEARING’s CDX-HS series platform — a lineage synonymous with hydraulic precision and mechanical durability — this unit delivers consistent fluid transfer performance even under conditions of elevated temperature, high humidity, mechanical vibration, and corrosive exposure. Whether deployed in a chemical processing plant, a water treatment facility, or a heavy industrial production line, the CDX-HS/A 70/07 is built to keep critical systems running without interruption.
Industrial automation environments place extreme demands on fluid-handling equipment. Pumps must operate reliably alongside PLC control systems, DCS distributed control architectures, variable frequency drives (VFDs), and industrial power supplies — all of which depend on stable fluid pressure and flow to maintain process integrity. The CDX-HS/A 70/07 integrates seamlessly into such control architectures, accepting analog or digital command signals from I/O modules and safety relay systems to enable precise, automated flow regulation. Its robust motor construction resists electromagnetic interference (EMI) commonly generated by nearby inverter drives and high-current switching equipment, ensuring that pump operation remains stable even in electrically noisy environments.
In harsh-environment deployments — including offshore oil and gas platforms, underground mining operations, metallurgical cooling circuits, and power generation auxiliary systems — the CDX-HS/A 70/07 demonstrates the industrial resilience that BEARING’s CDX-HS series is known for. The pump’s sealed motor housing and corrosion-resistant hydraulic components provide effective protection against dust ingress, water splash, and chemical vapors, making it suitable for Zone 2 classified areas and other locations where equipment reliability directly impacts personnel safety and production continuity.
Rugged Specifications Table
| Parameter |
Specification |
| Model |
CDX-HS/A 70/07 |
| SKU |
HP+/V-0010-02170-EN-0020-85925-CDXHS-A-70-07 |
| Brand / Series |
BEARING / CDX-HS Series |
| Pump Type |
Single-Stage Centrifugal Pump |
| Origin |
Italy |
| Max Flow Rate |
70 L/min (nominal, per CDX-HS/A series rating) |
| Max Head |
~7 m (0.7 bar, per CDX-HS/A 70/07 hydraulic curve) |
| Motor Protection |
IP44 / IP55 (motor enclosure, per CDX-HS series standard) |
| Operating Temperature |
Liquid: 0°C to +35°C; Ambient: up to +40°C |
| Vibration Resistance |
Designed for continuous industrial duty; anti-vibration motor mount |
| EMI Resistance |
Shielded motor windings; compatible with VFD-driven environments |
| Corrosion Protection |
Stainless steel impeller and pump body; corrosion-resistant hydraulic path |
| Compatibility |
Compatible with PLC/DCS analog output modules, safety relay systems, industrial I/O |
| Application Sectors |
Water treatment, chemical processing, HVAC, oil & gas auxiliary, metallurgy |
| Warranty |
12 Months — covers manufacturing defects and functional failure under normal use |
| Inspection & Testing |
Each unit inspected and function-tested prior to shipment |
Comprehensive Protection Solutions
The CDX-HS/A 70/07 is most effective when integrated as part of a complete industrial control and protection architecture. In typical process automation installations, this pump operates under the supervisory control of a Siemens S7-300 or S7-1500 PLC, receiving start/stop commands via digital output modules such as the SM 322 DO 16×DC 24V or equivalent I/O cards. Flow rate modulation is commonly achieved through a Siemens SINAMICS G120 variable frequency drive, which adjusts motor speed in response to analog setpoints from the PLC’s analog output module.
For installations requiring functional safety compliance, the pump circuit is typically protected by a Siemens SIRIUS 3SK1 safety relay module or a Pilz PNOZ safety controller, which monitors motor current, thermal overload, and emergency stop signals. Upstream power quality is maintained by an industrial UPS module (such as the Siemens SITOP PSU8600) to prevent pump damage during voltage transients or brief supply interruptions. Terminal connections within the control cabinet are managed using Phoenix Contact or Weidmüller terminal blocks, ensuring reliable, vibration-proof wiring in high-shock environments.
Communication between the pump control subsystem and the plant-level DCS is typically handled via PROFIBUS DP or PROFINET communication modules, enabling real-time monitoring of pump status, fault diagnostics, and predictive maintenance data. In installations where the CDX-HS/A 70/07 is part of a larger fluid management system, it may operate alongside pressure transmitters, flow meters, and level sensors connected to the same I/O bus, providing a fully integrated process view from the control room.
Application in Critical Infrastructure
The BEARING CDX-HS/A 70/07 has established a strong track record across critical infrastructure sectors where pump failure carries significant operational and safety consequences.
Oil & Gas: In upstream and midstream facilities, the CDX-HS/A 70/07 is used for cooling water circulation, chemical injection auxiliary circuits, and seal flush systems. Its resistance to vibration and EMI makes it well-suited for installation near compressor skids and high-power motor control centers (MCCs).
Mining & Metallurgy: Underground mining operations and surface metallurgical plants rely on the CDX-HS series for dewatering auxiliary circuits, cooling water supply to furnace control panels, and hydraulic fluid transfer in ore processing equipment. The pump’s sealed construction resists the fine particulate contamination prevalent in these environments.
Power Generation: In thermal and hydroelectric power plants, the CDX-HS/A 70/07 supports auxiliary cooling circuits for transformer cooling systems, battery room ventilation water supply, and turbine lube oil cooling. Continuous-duty operation at rated conditions is a baseline requirement in these applications, and the CDX-HS series delivers accordingly.
Water & Wastewater Treatment: Municipal and industrial water treatment facilities deploy the CDX-HS/A 70/07 for chemical dosing feed circuits, filter backwash auxiliary supply, and process water transfer. Its stainless steel hydraulic path ensures compatibility with treated water and mild chemical solutions.
Heavy Manufacturing: Automotive assembly plants, steel mills, and large-scale food processing facilities use the CDX-HS series in cooling tower makeup water circuits, CNC machine tool coolant supply, and HVAC chilled water distribution — applications where unplanned downtime directly translates to production loss.
Security & Quality FAQ
Q1: What does the 12-month warranty cover, and how is a claim processed?
The 12-month warranty covers all manufacturing defects, component failures, and functional anomalies that arise under normal operating conditions as specified in the CDX-HS/A 70/07 datasheet. To initiate a warranty claim, contact TOPNLMS at [email protected] with the order number, a description of the fault, and photographic evidence. Replacement units or repair services are dispatched within 5 business days of claim approval.
Q2: How is each unit tested before shipment?
Every CDX-HS/A 70/07 unit undergoes a pre-shipment inspection protocol that includes visual inspection for physical damage, electrical continuity testing of motor windings, insulation resistance measurement, and a functional run test to verify hydraulic performance. Units that do not meet BEARING’s factory acceptance criteria are quarantined and not shipped. A test report is available upon request.
Q3: Is the CDX-HS/A 70/07 compatible with my existing PLC or DCS control system?
Yes. The CDX-HS/A 70/07 is a standard three-phase or single-phase induction motor-driven pump (per the CDX-HS/A series specification) and is compatible with any PLC or DCS system capable of providing a standard digital or analog control output. It is routinely integrated with Siemens, Allen-Bradley, Schneider Electric, ABB, and Mitsubishi control platforms. For VFD-driven applications, ensure the drive’s output frequency range matches the motor’s rated frequency (50 Hz or 60 Hz as applicable).
Q4: Can TOPNLMS guarantee long-term supply and provide replacement support?
Yes. TOPNLMS maintains dedicated stock of BEARING CDX-HS series pumps and spare parts to support both immediate replacement needs and planned maintenance programs. For critical infrastructure operators requiring guaranteed availability, we offer reserved stock agreements and priority fulfillment. Contact [email protected] or call +86 18359293191 to discuss long-term supply arrangements.