BOSCH KM 3300-T 054915-103 Ruggedized DC Bus Capacitor Module
3300-TBOSCH Rexroth KM 3300-T 054915-103 KM3300 DC Bus Capacitor Module. Ruggedized for harsh industrial environments. In stock, tested, 12-month warranty. Fast shipping.
Request availability, condition, lead time and export shipping details for 81001-451-62-R.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Basler Electric 81001-451-62-R is a 1500A SGCT (Symmetrical Ground Current Transformer) matched pair designed for ground fault detection in industrial power protection and control systems. As aging protection relay panels built around legacy Basler SGCT Series components reach end-of-service life, facilities engineers and procurement teams increasingly require a verified, drop-in replacement that preserves existing wiring topology, relay coordination settings, and panel real estate — without forcing a full protection scheme redesign.
TOPNLMS stocks the 81001-451-62-R as a direct replacement and upgrade solution for industrial sites transitioning away from discontinued or hard-to-source Basler SGCT matched pairs. Whether your existing installation is built around a Basler BE1-GPS100 ground fault protection relay, a BE1-11g generator protection relay, or an older BE1-51/27C voltage-controlled overcurrent relay, the 81001-451-62-R integrates without requiring secondary wiring modifications or burden recalculation in most standard configurations.
| Parameter | Legacy / Outgoing Model | 81001-451-62-R (Replacement) |
|---|---|---|
| Series | Basler SGCT (earlier revisions) | Basler SGCT Series (current) |
| Primary Rating | 1500A (matched pair) | 1500A (matched pair) |
| Application | Ground fault detection, generator protection | Ground fault detection, generator protection |
| Secondary Interface | Standard CT secondary terminals | Standard CT secondary terminals — direct swap |
| Mounting / Physical Fit | Panel or bus-bar mount | Panel or bus-bar mount — same footprint |
| Relay Compatibility | BE1-GPS100, BE1-11g, BE1-51/27C and equivalents | Compatible with same relay families |
| Wiring Modification Required | — | None in standard configurations |
| Replacement Recommendation | Discontinued / aging stock | Direct drop-in replacement |
| Warranty | — | 12-Month Warranty (TOPNLMS) |
A successful migration from a legacy ground fault protection scheme to a modernized panel built around the 81001-451-62-R typically involves coordinating several interdependent components. In generator protection applications, the SGCT matched pair works in conjunction with the Basler BE1-GPS100 ground fault protection relay, which provides the zero-sequence current sensing logic that the CT pair feeds. Sites upgrading from older relay panels may also be replacing the BE1-11g generator protection relay, a multi-function device that consolidates overcurrent, voltage, frequency, and ground fault elements — making the CT interface a critical compatibility checkpoint.
For facilities running switchgear or motor control centers where the 81001-451-62-R is installed on a bus bar, the associated Basler BE1-51/27C voltage-controlled overcurrent relay often shares the same secondary CT circuit. Verifying burden compatibility across both the ground fault CT and the overcurrent CT inputs is a standard commissioning step during retrofit. In many installations, a Basler BE1-CDS240 differential protection relay is also present in the same protection zone, and its differential CT inputs must be re-verified after any SGCT replacement to confirm that zero-sequence compensation settings remain valid.
Beyond the relay and CT layer, the physical retrofit often requires attention to the control power supply feeding the relay panel — typically a Basler BE1-PS24 or equivalent 24VDC/125VDC auxiliary power supply module. Confirming that the power supply output remains within specification after adding or replacing protection elements prevents nuisance trips during commissioning. Communication-equipped relay panels may also include a Basler DECS-200 or DECS-250 digital excitation control system, which interfaces with the generator protection relay via RS-485 or Ethernet; these communication links should be verified as part of the overall system checkout after the CT replacement is complete.
For sites where the 81001-451-62-R is being installed as part of a broader panel modernization — replacing not just the CT pair but also aging terminal blocks, test switches, and secondary injection test points — coordinating the CT replacement with the panel builder’s schedule minimizes total outage time. TOPNLMS can supply the 81001-451-62-R as a standalone component or as part of a coordinated procurement that includes associated Basler protection relay modules, ensuring that all parts arrive together and are tested before the scheduled maintenance window.
Q: Can I replace the existing SGCT matched pair without rewiring the secondary circuit?
A: In the vast majority of standard installations, yes. The 81001-451-62-R maintains the same secondary terminal configuration as earlier SGCT revisions. Verify secondary burden and polarity markings before energizing.
Q: Do I need to update relay settings after replacing the CT pair?
A: If the replacement CT has the same ratio and accuracy class as the outgoing unit, existing relay coordination settings typically remain valid. Confirm the CT ratio and accuracy class match your relay’s input specification before closing the protection scheme.
Q: Is the 81001-451-62-R compatible with third-party ground fault relays?
A: The SGCT matched pair outputs a standard CT secondary signal. Compatibility with non-Basler relays depends on the relay’s CT input burden and zero-sequence sensing method. Consult your relay’s CT input specification.
Q: What is the lead time and shipping arrangement?
A: TOPNLMS ships from Xiamen, China. In-stock units are dispatched within 1–3 business days. Express air freight options are available for urgent replacement scenarios to minimize plant downtime.
Q: What documentation is provided with the unit?
A: Each unit ships with a test report, packing list, and TOPNLMS 12-month warranty certificate. Basler Electric original datasheet references are available upon request.
Every Basler Electric 81001-451-62-R shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to dispatch, each unit undergoes a pre-shipment functional inspection to verify physical integrity, terminal condition, and labeling accuracy. In the event of a confirmed defect within the warranty period, TOPNLMS provides replacement support with priority processing to minimize impact on your maintenance schedule.
Our procurement assurance includes: accurate SKU verification against your purchase order, secure export packaging rated for international air and sea freight, full traceability documentation, and responsive after-sales support via email and phone. For time-critical plant shutdowns or emergency replacement scenarios, contact our team directly to arrange expedited handling.
TOPNLMS is committed to supporting industrial facilities through every stage of control system modernization — from sourcing hard-to-find legacy components to supplying current-production replacements that extend the service life of your protection infrastructure.
Click Quote This Model and the Part Number field will auto-fill with 81001-451-62-R.