Language English USD Currency
Call WhatsApp RFQ
Allen-Bradley Industrial Automation Part

Allen-Bradley 6176M-19PT Replacement for 6176M Series

Request availability, condition, lead time and export shipping details for 6176M-19PT.

Allen-Bradley

6176M-19PT

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part Number6176M-19PT
CategoryHMI
ConditionAvailability Check
Lead TimeRFQ Confirmation
Series6176M
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Allen-Bradley 6176M-19PT Replacement for 6176M Series: Seamless Transition & Legacy System Compatibility

The Allen-Bradley 6176M-19PT is a 19-inch resistive touch industrial monitor designed for demanding factory-floor and control-room environments. As legacy Rockwell Automation HMI panels and operator interface terminals reach end-of-life, facilities running older 6176M Series displays — including the 6176M-15PT, 6176M-17PT, and 6176M-19PT — face increasing pressure to source verified replacement units or execute a controlled upgrade before unplanned downtime forces an emergency shutdown. TOPNLMS maintains ready stock of the 6176M-19PT to support both direct swap-out and phased migration strategies, with same-week dispatch from our Xiamen warehouse.

Migrating from an aging operator workstation or a discontinued Panel PC to the 6176M-19PT requires careful attention to physical mounting dimensions, video signal compatibility, and power supply specifications. The 6176M-19PT accepts a standard VGA input and operates on 24 VDC, making it electrically compatible with the majority of existing Allen-Bradley PanelView Plus 7 and PanelView 5500 controller architectures without rewiring the control cabinet. Engineers replacing a failed 6176M-15PT or 6176M-17PT will find that the VESA-compatible rear mounting pattern and the front-panel cutout dimensions of the 6176M-19PT allow a straightforward panel retrofit with minimal mechanical modification.

For sites running ControlLogix L7x or CompactLogix L3x controllers, the 6176M-19PT integrates directly into the existing Ethernet/IP network topology. No changes to the RSLogix 5000 or Studio 5000 project are required when the monitor is used as a passive display driven by a PanelView Plus 7 terminal or a PC-based FactoryTalk View SE workstation. Where the legacy system relied on a serial RS-232 connection to an older PanelView 550 or PanelView 900, the migration path typically involves adding a 1761-NET-ENI Ethernet interface module or upgrading the communication bridge, both of which can be sourced alongside the 6176M-19PT to complete the retrofit in a single purchase order.

Control cabinet space is a frequent constraint during HMI modernization projects. The 6176M-19PT’s slim-bezel design and standard NEMA 4/4X front-panel rating allow it to replace older, deeper-chassis monitors without requiring enclosure expansion. When the retrofit also involves replacing a 1756-A7 or 1756-A13 ControlLogix chassis backplane or adding a 1756-EN2T EtherNet/IP communication module to extend network reach, the 6176M-19PT’s low-profile installation footprint preserves the thermal headroom needed for those additional components.

Wiring compatibility is straightforward: the 6176M-19PT uses a standard 15-pin HD-15 VGA connector and a locking 24 VDC power connector consistent with the broader 6176M family. Technicians familiar with the 6176M-15PT or 6176M-17PT will recognize the connector layout immediately, reducing commissioning time. The resistive touch overlay is driven by a USB HID interface, eliminating the need for a dedicated touch controller card and simplifying driver management on Windows-based industrial PCs or thin-client terminals.

For facilities executing a broader DCS or SCADA modernization — for example, migrating from a legacy Bailey INFI 90 or Honeywell TDC 3000 operator station to a Rockwell-based architecture — the 6176M-19PT serves as the display layer in the new operator workstation stack. Paired with a 1769-L36ERM CompactLogix controller and a 1734 POINT I/O distributed I/O rack, the 6176M-19PT provides a cost-effective, standards-compliant operator interface that meets modern cybersecurity and network segmentation requirements without the capital expenditure of a full PanelView Plus 7 integrated terminal.

Compatibility Comparison Table

Parameter Legacy / Replaced Model 6176M-19PT (Replacement)
Screen Size 6176M-15PT (15″), 6176M-17PT (17″) 19″ (diagonal)
Touch Technology Resistive (analog) Resistive (USB HID)
Video Interface VGA (HD-15) VGA (HD-15) — direct compatible
Power Supply 24 VDC 24 VDC — no rewiring required
Mounting Standard VESA / Panel cutout VESA / Panel cutout — compatible
Front Panel Rating NEMA 4 / IP65 NEMA 4/4X / IP65
Communication Serial RS-232 (legacy) / Ethernet USB HID touch; host PC handles network
Controller Compatibility PanelView 550/900, ControlLogix L6x PanelView Plus 7, ControlLogix L7x, CompactLogix L3x
Installation Depth Deeper chassis (older units) Slim-bezel, reduced depth
Replacement Recommendation Direct swap for 6176M-15PT / 17PT ✔ Recommended upgrade path
Warranty Expired / EOL 12-Month Warranty (TOPNLMS)

Seamless Upgrade Solutions

A successful 6176M-19PT retrofit rarely involves a single component. Most migration projects require a coordinated set of hardware to ensure the new display integrates cleanly with the existing control architecture. When replacing a legacy operator station, engineers commonly source the following alongside the 6176M-19PT:

  • 1756-EN2T EtherNet/IP Communication Module — extends Ethernet/IP connectivity to the ControlLogix backplane, enabling the 6176M-19PT host PC to communicate with the controller over a standard network switch without adding a separate gateway.
  • 1761-NET-ENI Serial-to-Ethernet Interface — bridges legacy RS-232 PanelView terminals to the Ethernet/IP network, allowing a phased migration where the 6176M-19PT coexists with older serial-connected devices during the transition period.
  • 1734-AENT POINT I/O EtherNet/IP Adapter — connects distributed 1734 POINT I/O modules to the Ethernet/IP network, commonly added when the retrofit also involves replacing legacy remote I/O racks with modern distributed I/O.
  • 1769-PA2 CompactLogix Power Supply Module — provides regulated 24 VDC to the CompactLogix system bus; frequently replaced during HMI modernization to ensure the power budget accommodates the new display and any additional I/O modules.
  • 1756-A7 ControlLogix 7-Slot Chassis — the standard backplane for ControlLogix L7x controllers; often upgraded in parallel with the HMI display when the existing chassis is at capacity or showing age-related reliability issues.
  • 2711P-RDT15C PanelView Plus 7 Standard Terminal — for sites that prefer an integrated HMI solution rather than a PC-plus-monitor architecture; the 6176M-19PT is the preferred display companion when a separate industrial PC is already in place.
  • 1492-CABLE Series Programming Cables — used during commissioning to connect a laptop to the ControlLogix or CompactLogix controller for program upload, verification, and online monitoring while the new 6176M-19PT display is being configured.
  • 1783-US5T Stratix 2000 Unmanaged Switch — a DIN-rail-mounted industrial Ethernet switch commonly added to the control cabinet when the 6176M-19PT host PC, the controller, and remote I/O adapters all require network connectivity within the same enclosure.
  • 1492-IFM40F120A Terminal Block Interface Module — simplifies field wiring termination when the retrofit involves re-terminating analog or digital I/O signals from legacy cable harnesses to the new I/O modules installed alongside the 6176M-19PT.
  • Signal Isolators (e.g., MTL5541 or Phoenix Contact MACX series) — recommended when migrating from older DCS field wiring where ground loops or signal noise may affect the integrity of analog inputs connected to the new control system.

Retrofit Guidance FAQ

Q: Can the 6176M-19PT replace a 6176M-15PT or 6176M-17PT without modifying the panel cutout?
A: The 6176M-19PT has a larger screen and a correspondingly larger panel cutout requirement. A minor cutout enlargement is typically required when upgrading from a 15″ or 17″ unit. The mounting depth and power connector are compatible, so no cabinet rewiring is needed.

Q: Does the 6176M-19PT require any driver installation on the host PC?
A: The resistive touch overlay uses a standard USB HID interface recognized natively by Windows 7, Windows 10, and Windows 11. No third-party touch driver is required in most configurations. The VGA video output is handled by the host PC’s graphics adapter.

Q: Is the 6176M-19PT compatible with FactoryTalk View SE and ME?
A: Yes. The 6176M-19PT functions as a standard VGA display. FactoryTalk View SE (Server Edition) running on an industrial PC connected to the monitor operates normally. FactoryTalk View ME is typically used with integrated PanelView terminals rather than standalone monitors.

Q: What communication protocol does the 6176M-19PT use?
A: The 6176M-19PT is a display device; it does not independently implement a PLC communication protocol. Network communication (Ethernet/IP, Modbus TCP, etc.) is handled by the host PC or controller. The monitor connects to the host via VGA (video) and USB (touch).

Q: Can this monitor be used in a hazardous or wash-down environment?
A: The 6176M-19PT carries a NEMA 4/4X front-panel rating, making it suitable for wash-down and dust-tight applications. It is not rated for Class I Division 1 hazardous locations. Consult the product datasheet for full environmental specifications before installation in classified areas.

Q: How long does commissioning typically take for a direct swap replacement?
A: For a direct 6176M-to-6176M swap where the host PC and cabling remain unchanged, on-site commissioning typically takes 1–3 hours, including mechanical installation, cable reconnection, touch calibration, and display verification. More complex retrofits involving controller or network upgrades will require additional time.

Warranty Assurance

Every Allen-Bradley 6176M-19PT unit shipped by TOPNLMS is covered by a 12-month warranty from the date of dispatch. Prior to shipment, each unit undergoes a functional pre-shipment inspection covering power-on verification, VGA signal integrity, resistive touch calibration, and front-panel seal integrity. Units that do not pass inspection are quarantined and not shipped.

In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund within the warranty period. Our after-sales response target is one business day for initial acknowledgment and three business days for resolution proposal. Warranty coverage includes manufacturing defects and functional failures under normal operating conditions; it does not cover physical damage caused by improper installation or electrical overstress.

For procurement teams requiring documentation, TOPNLMS can provide a certificate of conformance, packing list, and commercial invoice with each shipment. Express shipping options (DHL, FedEx, UPS) are available for urgent replacement orders requiring delivery within 3–5 business days to most international destinations.

To place an order or request a compatibility consultation, contact our technical sales team:
📧 [email protected]
📞 +86 18359293191
🌐 https://topnlms.com


© 2026 TOPNLMS. All rights reserved. Original Source: https://topnlms.com | Contact: [email protected] | +86 18359293191

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with 6176M-19PT.