Allen-Bradley 2711P-RC3 Original Industrial Spare PanelView Plus Compatible
2711P-RC3Allen-Bradley 2711P-RC3 original CompactFlash storage card for PanelView Plus HMI. Industrial replacement spare, 12-month warranty, fast worldwide shipping.
Request availability, condition, lead time and export shipping details for 2711P-T6C5D.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Allen-Bradley 2711P-T6C5D is a 6-inch color touchscreen HMI terminal from the PanelView Plus 6 Compact series, designed for integration with Rockwell Automation’s ControlLogix, CompactLogix, MicroLogix, and SLC 500 control platforms. As legacy PanelView 550, PanelView 600, and PanelView Plus 5 terminals reach end-of-life, the 2711P-T6C5D has become the preferred drop-in upgrade path for facilities seeking to modernize operator interfaces without redesigning the entire control architecture.
At TOPNLMS, we supply tested and verified 2711P-T6C5D units with full traceability, ready for immediate dispatch. Whether you are replacing a failed unit on a production line or executing a planned migration from discontinued PanelView models, our inventory supports both emergency and scheduled procurement cycles.
| Parameter | Legacy Model (e.g. 2711-T6C8) | 2711P-T6C5D (PanelView Plus 6 Compact) |
|---|---|---|
| Display Size | 6″ Color TFT | 6″ Color TFT (QVGA 320×240) |
| Communication Interface | DH-485 / RS-232 | EtherNet/IP (RJ-45) + RS-232 |
| Power Supply | 24 VDC | 24 VDC (18–32 VDC range) |
| Mounting Cutout | Panel cutout ~192×138 mm | Panel cutout 192×138 mm (compatible) |
| Operating System | Proprietary firmware | Windows CE 6.0 + FactoryTalk View ME |
| Programming Software | PanelBuilder 32 | FactoryTalk View Studio ME |
| PLC Compatibility | SLC 500, PLC-5 | ControlLogix, CompactLogix, MicroLogix, SLC 500, PLC-5 (via drivers) |
| USB Port | None | USB Type-A (program transfer & data logging) |
| Replacement Recommendation | Direct panel cutout reuse; rewire to EtherNet/IP; convert application in FactoryTalk View Studio ME | |
| Warranty (TOPNLMS Supply) | — | 12-Month Warranty |
A successful migration from a legacy PanelView or PanelView Plus 5 terminal to the 2711P-T6C5D typically involves coordinating several interconnected components within the same control cabinet or rack. The 2711P-T6C5D communicates natively over EtherNet/IP, so facilities previously running DH-485 or DH+ networks will need to evaluate their network topology. In many cases, a 1761-NET-ENI Serial-to-EtherNet/IP adapter or a 1747-AENTR EtherNet/IP adapter for SLC 500 racks can bridge legacy backplane communications to the new HMI without replacing the entire PLC system.
For sites running ControlLogix or CompactLogix platforms, the 2711P-T6C5D connects directly to the controller’s EtherNet/IP port. If the existing 1756-ENBT or 1756-EN2T Ethernet communication module is already installed in the ControlLogix chassis, no additional hardware is required on the PLC side. The HMI application is developed or converted using FactoryTalk View Studio ME, and the runtime license is embedded in the 2711P-T6C5D firmware.
Power wiring is straightforward: the 2711P-T6C5D accepts 24 VDC from the existing panel power supply, typically a 1606-XLP or equivalent 24 VDC regulated power supply already present in the control cabinet. No separate transformer or power conditioning is required in most standard installations.
For I/O-intensive applications where the HMI must display real-time analog and digital signals from remote I/O racks, the 2711P-T6C5D works seamlessly alongside 1734 POINT I/O modules and 1769 Compact I/O modules connected to the same EtherNet/IP network. Tag-based addressing in FactoryTalk View ME allows direct mapping to controller tags without intermediate data table configuration.
In retrofit projects where the control cabinet also houses a 1756-L7x or 1756-L8x ControlLogix controller, the 2711P-T6C5D can be mounted in the same panel door cutout as the legacy terminal, preserving the original enclosure and minimizing mechanical modification. A 2711P-RN15S EtherNet/IP communication module is not required for the 2711P-T6C5D as EtherNet/IP is built into the base unit, simplifying the bill of materials compared to earlier PanelView Plus 6 Standard models.
For applications requiring data logging or recipe management, the USB port on the 2711P-T6C5D supports standard USB flash drives, eliminating the need for a separate 2711P-RY2032 CompactFlash card used in older PanelView Plus terminals. This simplifies long-term maintenance and reduces spare parts inventory at the plant level.
Q: Can I reuse the existing panel cutout from a PanelView 600 or PanelView Plus 5 terminal?
A: In most cases, yes. The 2711P-T6C5D shares a compatible 192×138 mm panel cutout dimension with many 6-inch PanelView models. Verify the exact cutout dimensions of your legacy unit before installation. Minor filing or adapter plates may be required in some enclosure configurations.
Q: Do I need to rewire the communication cable?
A: If your legacy terminal used DH-485 or RS-232 for PLC communication, you will need to add an EtherNet/IP network drop to the panel or use a serial-to-EtherNet/IP adapter. If your system already has an EtherNet/IP network, simply connect a standard Cat5e or Cat6 patch cable to the RJ-45 port on the 2711P-T6C5D.
Q: Can I convert my existing PanelBuilder 32 or FactoryTalk View ME 5.x application?
A: PanelBuilder 32 applications (.pba files) must be manually recreated in FactoryTalk View Studio ME, as direct import is not supported. FactoryTalk View ME 5.x applications (.mer files) can generally be opened and recompiled in a newer version of FactoryTalk View Studio ME with minor tag and driver updates.
Q: Is the 2711P-T6C5D compatible with MicroLogix 1100 and MicroLogix 1400 controllers?
A: Yes. The 2711P-T6C5D supports EtherNet/IP communication with MicroLogix 1100 and MicroLogix 1400 controllers using the DF1 over EtherNet/IP or Logix driver in FactoryTalk View Studio ME.
Q: What is the physical installation space requirement?
A: The 2711P-T6C5D requires a minimum panel depth of approximately 65 mm behind the cutout for the terminal body and connector clearance. Ensure adequate depth in your existing enclosure before installation.
Q: Can the 2711P-T6C5D communicate with third-party PLCs via Modbus or PROFIBUS?
A: The 2711P-T6C5D natively supports EtherNet/IP and DF1 Serial protocols. Third-party PLC communication via Modbus TCP is possible using the Modbus TCP driver available in FactoryTalk View Studio ME. PROFIBUS is not natively supported.
Every 2711P-T6C5D unit supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each unit undergoes functional verification including power-on testing, display integrity check, touchscreen calibration verification, and communication port inspection. Units that do not pass our outgoing quality inspection are not shipped.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund within the warranty period. Our after-sales response team is available to assist with technical questions related to installation, wiring, and communication configuration. We maintain buffer stock of common PanelView Plus 6 Compact models to support rapid replacement dispatch for production-critical situations.
For bulk procurement, project-based orders, or scheduled maintenance contracts requiring multiple units, please contact our sales team directly to discuss lead times, pricing, and logistics arrangements.
Click Quote This Model and the Part Number field will auto-fill with 2711P-T6C5D.