Allen-Bradley 2711P-RC3 Original Industrial Spare PanelView Plus Compatible
2711P-RC3Allen-Bradley 2711P-RC3 original CompactFlash storage card for PanelView Plus HMI. Industrial replacement spare, 12-month warranty, fast worldwide shipping.
Request availability, condition, lead time and export shipping details for 2711P-T6C20A.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Allen-Bradley 2711P-T6C20A is a 6-inch color TFT touch terminal from the PanelView Plus 600 series, manufactured by Rockwell Automation. As a cornerstone HMI component in countless manufacturing lines, process control panels, and discrete automation systems worldwide, this unit plays a critical role in operator interaction, real-time process visualization, and alarm management. Securing a verified original spare of the 2711P-T6C20A is one of the most impactful steps a maintenance team can take to protect system uptime, reduce mean time to repair (MTTR), and extend the operational life of aging control architectures.
Whether your facility runs continuous production, batch processing, or discrete assembly, an unexpected HMI failure can cascade into full line stoppage within minutes. The 2711P-T6C20A is a direct plug-and-play replacement for existing PanelView Plus 600 installations — no re-engineering, no firmware migration headaches, no compatibility guesswork. Stocking this unit as a critical spare is a straightforward, cost-justified decision for any maintenance manager responsible for Rockwell-based control systems.
| Parameter | Specification |
|---|---|
| Part Number | 2711P-T6C20A |
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation |
| Series | PanelView Plus 600 |
| Display Type | 6-inch Color TFT LCD |
| Interface | Touch Screen (Resistive) |
| Communication Ports | RS-232, USB, Ethernet (10/100 Mbps) |
| Operating Voltage | 24 VDC |
| Operating Temperature | 0°C to 55°C (32°F to 131°F) |
| Storage Temperature | -20°C to 70°C |
| Protection Rating | NEMA 4/4X, 12, 13 (front panel); IP65 |
| Memory | 64 MB RAM / 128 MB Flash |
| Compatible Software | FactoryTalk View ME |
| Compatible Controllers | ControlLogix, CompactLogix, MicroLogix, SLC 500, PLC-5 |
| Mounting | Panel cutout mount, standard PanelView Plus 600 footprint |
| Country of Origin | United States |
| Condition | Original / Genuine |
| Warranty | 12 Months |
A proactive maintenance approach for any PanelView Plus 600 installation extends well beyond the HMI terminal itself. During scheduled downtime or annual control cabinet inspections, maintenance teams should treat the 2711P-T6C20A replacement as part of a broader system health review. The HMI communicates directly with the controller backplane and relies on a stable 24 VDC power supply — a failing or undersized power supply module such as the 1606-XLP95E or equivalent Rockwell 24V DC power supply is a common root cause of intermittent HMI resets and communication dropouts that are often misdiagnosed as HMI faults.
Inspect the communication cabling between the 2711P-T6C20A and the ControlLogix or CompactLogix controller. Ethernet patch cables and RS-232 serial cables degrade in high-vibration or high-temperature environments; replacing aged cables with shielded industrial-grade alternatives during the same maintenance window eliminates a frequent source of nuisance alarms. If your system uses a 1756-ENBT or 1756-EN2T Ethernet communication module in the ControlLogix chassis, verify firmware compatibility with the HMI’s FactoryTalk View ME application version before swapping the terminal.
For facilities running mixed I/O architectures, the inspection should extend to 1756-IB16 digital input modules and 1756-OB16E digital output modules in the same chassis. Loose terminal block connections on these I/O modules can produce erratic process signals that manifest as false alarms on the HMI screen — a problem that wastes operator time and masks genuine equipment faults. Similarly, 1492-J series terminal blocks and wiring duct within the control cabinet should be checked for insulation wear and secure seating.
If the control system includes remote I/O drops communicating over DeviceNet or ControlNet, inspect the 1756-DNB DeviceNet bridge module and associated trunk cable termination resistors. A degraded network segment will cause the HMI to display communication fault banners even when the terminal itself is fully functional. Addressing network integrity proactively — rather than reactively during a production stoppage — is a hallmark of mature industrial maintenance programs.
For older installations where the 2711P-T6C20A interfaces with legacy SLC 500 or PLC-5 controllers via RS-232, consider stocking a 1747-UIC USB-to-DH485 interface converter as a diagnostic tool. This allows rapid connection of a programming laptop for fault diagnosis without disturbing the HMI wiring. Pairing this with a spare 1747-L543 SLC 5/04 processor module in your critical spares inventory ensures that a controller failure does not extend downtime beyond the time required for a module swap.
The 2711P-T6C20A is a direct form-fit-function replacement for earlier PanelView Plus 600 units including the 2711P-T6C3A and 2711P-T6C5A. All three share the same panel cutout dimensions, 24 VDC power requirement, and FactoryTalk View ME application compatibility, meaning an existing application file (.MER) can be transferred to the replacement unit via USB without modification in most cases. This eliminates the need for costly re-commissioning or software re-engineering, making the 2711P-T6C20A the preferred upgrade path for facilities looking to standardize on a current-generation part while maintaining full backward compatibility with their existing control logic.
For facilities managing end-of-life PanelView 550 or PanelView 900 installations, the migration to the PanelView Plus 600 platform using the 2711P-T6C20A represents a cost-effective modernization step. The newer platform supports Ethernet connectivity natively, enabling integration with plant-wide SCADA systems and remote monitoring solutions without additional communication hardware. This upgrade path preserves the existing controller infrastructure — ControlLogix, CompactLogix, or SLC 500 — while delivering a modern operator interface with improved display resolution, faster boot times, and a broader ecosystem of compatible accessories.
Stocking the 2711P-T6C20A as a pre-configured hot spare — with the production application pre-loaded and verified — reduces field replacement time to under 30 minutes in most installations. This practice, combined with a documented replacement procedure stored in the control cabinet, is a best-practice recommendation for any facility where HMI downtime directly impacts production throughput or safety system availability.
Q1: Is this a genuine original Allen-Bradley 2711P-T6C20A or a compatible aftermarket unit?
This is a genuine original Allen-Bradley / Rockwell Automation 2711P-T6C20A. Each unit is sourced from authorized industrial supply channels and undergoes functional verification prior to shipment. A 12-month warranty is included covering manufacturing defects and operational failures under normal industrial use conditions.
Q2: Can I load my existing FactoryTalk View ME application directly onto the replacement unit?
Yes. The 2711P-T6C20A is fully compatible with FactoryTalk View ME application files (.MER). Transfer via USB is the standard method. Ensure the FactoryTalk View ME software version used to create the application is compatible with the firmware version on the replacement unit. In most cases, applications created on earlier PanelView Plus 600 firmware versions load without modification.
Q3: What is the lead time and how is the unit tested before shipment?
In-stock units are dispatched within 1–3 business days. Each 2711P-T6C20A is powered on and functionally tested — including display, touch interface, communication ports, and boot sequence — before packaging. Units are shipped in anti-static protective packaging with appropriate cushioning for international freight. Tracking information is provided upon dispatch.
Q4: How should I manage my critical spares inventory for PanelView Plus 600 systems?
For facilities with multiple PanelView Plus 600 terminals, a minimum of one pre-configured spare per site is recommended. For high-criticality lines where HMI failure triggers a safety interlock or production halt, consider maintaining two spares — one pre-loaded with the current application and one as a blank unit for emergency use. Annual inventory audits should verify that spare unit firmware and application versions remain synchronized with the production system to avoid compatibility issues during emergency replacements.
Click Quote This Model and the Part Number field will auto-fill with 2711P-T6C20A.