Allen-Bradley 2711P-RC3 Original Industrial Spare PanelView Plus Compatible
2711P-RC3Allen-Bradley 2711P-RC3 original CompactFlash storage card for PanelView Plus HMI. Industrial replacement spare, 12-month warranty, fast worldwide shipping.
Request availability, condition, lead time and export shipping details for 2711P-T15C22D9P.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Allen-Bradley 2711P-T15C22D9P is a PanelView Plus 7 Standard 15-inch color touch-screen HMI terminal engineered by Rockwell Automation for demanding industrial control environments. Whether you are migrating from an end-of-life PanelView Plus 6 terminal, retiring an aging PanelView 1000e, or consolidating a multi-panel control cabinet, this unit delivers a smooth, low-risk upgrade path that preserves your existing FactoryTalk View ME application logic, panel cutout dimensions, and EtherNet/IP network infrastructure.
Designed for integration with Allen-Bradley ControlLogix, CompactLogix, and MicroLogix controller families, the 2711P-T15C22D9P communicates natively over EtherNet/IP, eliminating the need for protocol converters or gateway modules when replacing older DH+ or DF1-based terminals. Its 15-inch SVGA display, 1024 × 768 resolution, and resistive touch interface match the physical footprint of the PanelView Plus 6 1500 series, allowing panel builders to reuse existing cutouts and mounting hardware with minimal rework.
| Parameter | Legacy Model (PanelView Plus 6 1500) | 2711P-T15C22D9P (PanelView Plus 7 Standard) |
|---|---|---|
| Display Size | 15″ Color TFT | 15″ Color TFT SVGA |
| Resolution | 1024 × 768 | 1024 × 768 |
| Touch Technology | Resistive | Resistive |
| Communication | EtherNet/IP, DF1, DH+ | EtherNet/IP (dual-port) |
| Panel Cutout | Compatible | Compatible (same form factor) |
| Runtime Software | FactoryTalk View ME 6.x | FactoryTalk View ME 9.0+ |
| Application Migration | Source | Direct import via ME Transfer Utility |
| Power Supply | 24 VDC | 24 VDC |
| Operating Temperature | 0–55 °C | 0–55 °C |
| Protection Rating | NEMA 4/4X, IP65 (front) | NEMA 4/4X, IP65 (front) |
| Replacement Recommendation | Direct drop-in upgrade | ✔ Recommended |
| Warranty | — | 12-Month Warranty (TOPNLMS) |
A successful migration from a legacy HMI platform to the 2711P-T15C22D9P typically involves coordinating several interconnected components within the same control cabinet or network segment. When the existing panel runs a ControlLogix L71 or L73 controller, the EtherNet/IP dual-port switch built into the PanelView Plus 7 allows the terminal to participate in a Device Level Ring (DLR) topology without adding an external managed switch, simplifying the network architecture during cutover.
For installations where the legacy terminal communicated via a 1784-U2DHP USB-to-DH+ adapter or a 1761-NET-AIC serial interface converter, the migration to EtherNet/IP on the 2711P-T15C22D9P eliminates these intermediate devices entirely. The controller’s existing 1756-EN2T or 1756-EN2TR EtherNet/IP communication module handles all HMI traffic directly, reducing wiring complexity and potential failure points in the panel.
In CompactLogix-based systems, the 2711P-T15C22D9P connects directly to the 1769-L33ER or 1769-L36ERM controller’s onboard EtherNet/IP port. Existing I/O wiring to 1769-IQ16 digital input modules and 1769-OB16 digital output modules remains completely unchanged during the HMI swap, as the controller program and I/O mapping are unaffected by the terminal replacement.
Where the control cabinet also houses a PowerFlex 525 or PowerFlex 755 variable frequency drive, the PanelView Plus 7 can display drive status, fault codes, and speed references via EtherNet/IP without additional programming, provided the drive is already on the same network segment. This integration is particularly valuable in water treatment, HVAC, and conveyor applications where operators need unified visibility from a single HMI screen.
For legacy panels that included a separate 2711P-RDK15C operator interface keypad module or a 2711P-RN15S remote I/O expansion unit, these accessories are forward-compatible with the PanelView Plus 7 platform, allowing partial reuse of existing hardware investments. The 2711P-T15C22D9P also supports the same 2711P-RY2032 CompactFlash memory card format used in PanelView Plus 6 terminals, enabling direct application backup and restore without reformatting.
Q1: Can I reuse my existing FactoryTalk View ME application from a PanelView Plus 6 without rewriting it?
Yes. Rockwell Automation’s ME Transfer Utility supports direct application migration from PanelView Plus 6 to PanelView Plus 7. Most graphic displays, alarm configurations, and tag bindings transfer without modification. Minor adjustments may be required for any screens that used platform-specific features deprecated in FactoryTalk View ME 9.0, but the core logic and tag database remain intact.
Q2: Does the 2711P-T15C22D9P fit the same panel cutout as the PanelView Plus 6 1500?
Yes. The PanelView Plus 7 Standard 15-inch series shares the same panel cutout dimensions as the PanelView Plus 6 1500 series. No panel modification is required. The mounting clamps and gasket seal are included, and the front bezel achieves NEMA 4/4X and IP65 protection when properly installed.
Q3: What communication protocols does the 2711P-T15C22D9P support, and is it backward-compatible with older Allen-Bradley networks?
The 2711P-T15C22D9P communicates natively over EtherNet/IP with dual-port DLR support. It does not include onboard DH+ or DF1 ports. If your existing controller communicates only via DH+ or serial DF1, a 1761-NET-ENI or 1783-ETAP Ethernet-to-DH+ bridge is required to maintain connectivity during the transition period, or the controller communication module should be upgraded to a 1756-EN2T simultaneously.
Q4: How is physical installation space managed when retrofitting into an existing enclosure?
The 2711P-T15C22D9P has a panel depth of approximately 95 mm behind the mounting surface. Verify that the existing enclosure provides at least 100 mm of clearance behind the panel door. The unit’s 24 VDC power connector and EtherNet/IP RJ-45 ports are rear-facing, so cable routing should be planned to avoid interference with adjacent components such as terminal blocks, DIN rail-mounted power supplies, or circuit breakers.
Every 2711P-T15C22D9P unit supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each unit undergoes a multi-point functional inspection that includes power-on verification, display uniformity check, touch calibration test, EtherNet/IP port continuity confirmation, and firmware version validation. Units that do not pass all inspection criteria are quarantined and not shipped.
In the event of a confirmed defect within the warranty period, TOPNLMS provides a replacement unit or full refund based on the customer’s preference. Our technical support team is available to assist with installation questions, compatibility verification, and commissioning guidance via email at [email protected] or by phone at +86 18359293191. Replacement units for warranty claims are typically dispatched within 3 business days of fault confirmation.
For customers managing planned maintenance schedules or critical production lines, TOPNLMS maintains buffer stock of high-demand Allen-Bradley HMI terminals to support emergency replacement orders with same-day or next-day dispatch where logistics permit. Long-term supply agreements and blanket purchase orders are available for OEM integrators and MRO procurement teams.
Click Quote This Model and the Part Number field will auto-fill with 2711P-T15C22D9P.