Allen-Bradley 2711P-RC3 Original Industrial Spare PanelView Plus Compatible
2711P-RC3Allen-Bradley 2711P-RC3 original CompactFlash storage card for PanelView Plus HMI. Industrial replacement spare, 12-month warranty, fast worldwide shipping.
Request availability, condition, lead time and export shipping details for 2711-K5A8.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Allen-Bradley 2711-K5A8 is a 5.5-inch keypad-only HMI terminal from the PanelView 550 series, communicating over DH-485 and designed for integration with legacy SLC 500 and MicroLogix controller platforms. As Rockwell Automation has discontinued active production of this model, facilities running aging control panels face increasing pressure to source reliable replacement units before critical downtime events occur. TOPNLMS supplies tested, ready-to-ship 2711-K5A8 units to support both emergency replacement and planned migration projects, backed by a 12-month warranty and pre-shipment functional verification.
For engineers managing a retrofit or modernization project, the 2711-K5A8 offers a direct drop-in path for existing PanelView 550 installations. The terminal mounts into a standard 5.5-inch panel cutout and retains the original DH-485 serial communication interface, meaning no rewiring of the communication trunk is required when swapping a failed unit. The keypad membrane layout is identical to earlier PanelView 550 revisions, so operator familiarity is preserved without retraining. Application files created in PanelView Transfer Utility or RSView32 are fully compatible and can be reloaded directly from the original backup, eliminating the need to rebuild screens from scratch.
In systems where the SLC 5/03, SLC 5/04, or MicroLogix 1100 serves as the host controller, the 2711-K5A8 communicates via the DH-485 network using the DF1 half-duplex or DH-485 protocol, depending on the configured node address and baud rate. No protocol conversion gateway is required for a like-for-like swap. If the migration scope extends to replacing the host controller as well—for example, upgrading from an SLC 5/04 to a CompactLogix L3x or L4x—the 2711-K5A8 can continue to serve as the operator interface during a phased transition, provided the new controller is configured with a 1761-NET-AIC or equivalent DH-485 adapter to maintain network continuity.
Physical installation is straightforward. The 2711-K5A8 uses a standard 24 VDC power supply input, compatible with existing 1606-XLP or 1606-XLS series power supplies already installed in most SLC-era control cabinets. The terminal depth behind the panel face is 63 mm, which fits within the majority of NEMA 12 and IP54-rated enclosures used in manufacturing and process environments. Gasket sealing is maintained by the original panel cutout hardware, so no additional sealing work is required during replacement.
For sites planning a longer-term migration away from the PanelView 550 platform entirely, the 2711-K5A8 replacement serves as a cost-effective bridge solution while the broader system architecture is redesigned. Engineers frequently pair this terminal with a 1747-UIC USB-to-DH-485 programming cable to re-establish RSLinx communication with the SLC controller during commissioning, and use a 1747-L553 or 1747-L552 SLC 5/05 processor if Ethernet connectivity is being introduced to the control network in parallel. Signal isolation between the DH-485 segment and any new Ethernet-based I/O drops can be managed with a 1761-NET-AIC interface converter, preserving the integrity of the legacy communication segment while new infrastructure is added.
Sites that are simultaneously upgrading their I/O infrastructure may be installing 1746-IB16 or 1746-OB16 digital I/O modules alongside the HMI replacement. In these cases, the 2711-K5A8 continues to display the same data tags mapped in the original application, requiring no screen modifications as long as the SLC rack configuration and I/O addressing remain unchanged. For analog signal monitoring, 1746-NI4 or 1746-NO4I analog I/O modules in the existing SLC rack are fully visible to the replacement terminal without any application file changes.
Procurement teams should note that TOPNLMS maintains stock of the 2711-K5A8 for immediate dispatch. Each unit undergoes a pre-shipment power-on test and communication verification before packaging. Standard lead time from order confirmation to shipment is 1–3 business days for in-stock units, with DHL Express and FedEx International Priority available for time-critical orders. Export documentation, including commercial invoice and packing list, is prepared in compliance with CN customs requirements for industrial electronic components.
| Parameter | Legacy / Replaced Unit | 2711-K5A8 (This Unit) |
|---|---|---|
| Model / SKU | 2711-K5A8 (failed/EOL unit) | 2711-K5A8 (tested replacement) |
| Series | PanelView 550 | PanelView 550 |
| Display Type | 5.5″ Keypad Only | 5.5″ Keypad Only |
| Communication Protocol | DH-485 / DF1 | DH-485 / DF1 (identical) |
| Compatible Controllers | SLC 500, MicroLogix | SLC 500, MicroLogix (same) |
| Power Supply | 24 VDC | 24 VDC (no change) |
| Panel Cutout | Standard PanelView 550 cutout | Drop-in fit (no modification) |
| Application File Compatibility | PanelView Transfer Utility / RSView32 | Fully compatible — reload from backup |
| Wiring Changes Required | — | None |
| Firmware | Factory original | Factory original / tested |
| Warranty | — | 12-Month Warranty (TOPNLMS) |
| Replacement Type | — | Direct drop-in replacement |
A successful PanelView 550 replacement rarely involves the HMI terminal in isolation. During the commissioning phase, a 1747-UIC USB-to-DH-485 programming cable is essential for re-establishing RSLinx communication between the engineering workstation and the SLC 500 controller rack. If the host processor is being upgraded concurrently, a 1747-L553 SLC 5/05 processor with built-in Ethernet/IP capability allows the control network to be extended without disrupting the existing DH-485 HMI segment. For sites introducing new remote I/O drops, a 1761-NET-AIC interface converter bridges the DH-485 segment to the new network infrastructure cleanly.
On the power distribution side, a 1606-XLP60E or 1606-XLS90E DIN-rail power supply provides stable 24 VDC to both the replacement 2711-K5A8 terminal and any additional I/O modules added during the retrofit. If the project scope includes expanding digital I/O capacity, 1746-IB16 input modules and 1746-OB16 output modules slot directly into the existing SLC rack without requiring a new backplane. For analog process signals, a 1746-NI4 analog input module handles 4–20 mA and 0–10 VDC signals from field instruments, maintaining full visibility on the replacement HMI screen without any application file modifications. Sites that require signal isolation between field devices and the control system can add a DIN-rail-mounted signal isolator/repeater in the same cabinet, protecting the SLC I/O modules from ground loops and transient voltages common in heavy industrial environments.
Q: Do I need to rewire the DH-485 communication cable when replacing the 2711-K5A8?
A: No. The replacement unit uses the same RJ45-style DH-485 port and pinout as the original. Disconnect the cable from the failed terminal and reconnect it to the replacement unit. No wiring changes are required.
Q: Can I reload my existing PanelView application file onto the replacement terminal?
A: Yes. Application files created in PanelView Transfer Utility are fully compatible. Connect the 1747-UIC programming cable, launch the Transfer Utility, and download the backup file directly to the replacement terminal.
Q: Will the replacement terminal work with my existing SLC 5/03 or SLC 5/04 processor?
A: Yes. The 2711-K5A8 communicates with SLC 5/03, 5/04, and 5/05 processors over DH-485 without any configuration changes to the controller. Node address and baud rate settings on the replacement terminal must match the original unit’s settings.
Q: What if my panel cutout is slightly worn or oversized from the previous installation?
A: The 2711-K5A8 uses a standard PanelView 550 mounting frame and gasket. Minor cutout wear is typically accommodated by the mounting clamps. If the cutout is significantly oversized, a standard panel repair kit or overlay plate can be used before installation.
Q: Is the replacement terminal compatible with RSView32 and FactoryTalk View ME?
A: The 2711-K5A8 is natively supported by RSView32 and PanelView Transfer Utility. FactoryTalk View ME is designed for the PanelView Plus/Plus 6/Plus 7 platform and is not applicable to the PanelView 550 series.
Q: How long does commissioning typically take after the physical swap?
A: For a direct like-for-like replacement with an existing application backup, commissioning typically takes 30–90 minutes, including physical installation, application download, communication verification, and functional test of all operator screens.
Every 2711-K5A8 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to shipment, each unit undergoes a power-on functional test, DH-485 communication verification, and keypad membrane inspection. Units that do not pass all test criteria are quarantined and not dispatched.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund within the warranty period. Customers are asked to provide a brief fault description and, where possible, a photo or video of the issue. Return shipping for warranty replacements is coordinated by TOPNLMS. Response time for warranty inquiries is within 1 business day.
For procurement teams requiring documentation, TOPNLMS can provide a test report, commercial invoice, and certificate of conformity upon request. All units are shipped in anti-static packaging with foam protection suitable for international air freight.
For volume orders, blanket purchase agreements, or expedited sourcing requirements, contact the TOPNLMS sales team directly.
Click Quote This Model and the Part Number field will auto-fill with 2711-K5A8.