Allen-Bradley 1746-P5 Ruggedized DC Power Supply Module
1746-P5Allen-Bradley 1746-P5 ruggedized DC power supply for SLC 500 PLC. Harsh environment rated, 12-month warranty, tested stock. Fast global shipping from TOPNLMS.
Request availability, condition, lead time and export shipping details for 1797-PS2E2.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Allen-Bradley 1797-PS2E2 is a dedicated intrinsically safe power supply module designed for the Rockwell Automation FLEX Ex I/O platform — a distributed I/O architecture widely deployed in hazardous-area process automation environments including oil & gas, chemical processing, and pharmaceutical manufacturing. As the 1797 FLEX Ex series approaches end-of-life and spare-part availability tightens, facilities running legacy control architectures face increasing pressure to source verified replacement units or plan a structured migration to a supported platform.
TOPNLMS supplies the 1797-PS2E2 as a direct replacement module, fully tested prior to shipment, with a 12-month warranty covering manufacturing defects and functional failure. Each unit is inspected against original Rockwell Automation specifications for output voltage, current capacity, and intrinsic safety barrier compliance before dispatch from our Xiamen warehouse. Orders are typically processed within 1–3 business days, with DHL Express and FedEx International Priority available for time-critical plant shutdowns or emergency maintenance windows.
| Parameter | 1797-PS2E2 (Original / Replacement) | Notes |
|---|---|---|
| Platform | Allen-Bradley FLEX Ex 1797 Series | Hazardous-area distributed I/O |
| Module Type | Intrinsically Safe Power Supply | Zone 1 / Zone 2 rated |
| Mounting | 1797 FLEX Ex backplane / terminal base | Direct slot-for-slot replacement |
| Communication | Backplane bus (no standalone fieldbus) | Compatible with 1797-AENTR, 1797-DNYI adapters |
| Wiring Interface | Screw-terminal via 1797-TB3 terminal base | Existing field wiring reusable |
| Power Input | 24V DC nominal | Verify supply rail before installation |
| Hazardous Area Rating | ATEX / IECEx Zone 1 & Zone 2 | Confirm local certification requirements |
| Replacement Scope | Drop-in module swap | No PLC program changes required |
| Warranty | 12 Months — covers manufacturing defects and functional failure from date of shipment | |
A successful 1797-PS2E2 replacement rarely occurs in isolation. In most FLEX Ex installations, the power supply module works in concert with a broader set of I/O and communication components that must be evaluated as part of any maintenance or migration project.
The 1797-AENTR EtherNet/IP adapter is the most common communication interface in modernized FLEX Ex racks, providing the backplane-to-Ethernet bridge that connects field I/O to a ControlLogix or CompactLogix controller. If your facility is migrating from an older DeviceNet-based architecture, the 1797-DNYI DeviceNet adapter may still be in service — and its compatibility with the replacement 1797-PS2E2 is maintained without firmware changes.
On the I/O side, analog input modules such as the 1797-IE8 (8-channel analog input) and digital output modules like the 1797-OE8 share the same backplane power bus supplied by the 1797-PS2E2. Verifying that the replacement power supply’s current budget covers all populated slots — including any 1797-IB8 digital input modules — is a critical pre-installation step that prevents nuisance trips during commissioning.
For facilities running a ControlLogix 1756 or CompactLogix 5380 controller as the upstream PLC, no changes to the RSLogix 5000 or Studio 5000 I/O tree are required when performing a like-for-like 1797-PS2E2 swap. The module identity and slot addressing remain unchanged, meaning the controller’s I/O configuration file does not need to be modified, downloaded, or re-verified — a significant advantage in environments where program change management is tightly controlled.
Where the existing 1797-TB3 terminal base is retained, field wiring from intrinsically safe sensors and transmitters connects directly without re-termination. This is particularly valuable in hazardous-area installations where hot-work permits and area classification procedures add significant time and cost to any wiring modification. If the terminal base itself is damaged or corroded, the 1797-TB3S spring-clamp variant is a compatible alternative that accepts the same module footprint.
For facilities considering a longer-term migration away from the FLEX Ex platform entirely, the 1794 FLEX I/O series (standard-area) or the Rockwell Automation POINT I/O 1734 platform with appropriate IS barriers represents the most common upgrade path. TOPNLMS can supply modules from both platforms to support phased migration projects where FLEX Ex and modern I/O architectures coexist during transition.
Q: Can I replace the 1797-PS2E2 without modifying my PLC program?
A: Yes. The 1797-PS2E2 is a power supply module with no software-configurable parameters visible to the controller. A like-for-like replacement requires no changes to your Studio 5000 or RSLogix 5000 project. The controller will resume normal I/O communication after the module seats correctly on the backplane.
Q: Do I need to re-terminate field wiring?
A: Not if the existing 1797-TB3 terminal base is undamaged. The power supply module separates from the terminal base without disturbing field wiring. This is one of the key advantages of the FLEX Ex modular architecture for hazardous-area maintenance.
Q: What communication protocols does the FLEX Ex rack support with this power supply?
A: The 1797-PS2E2 powers the backplane regardless of the communication adapter installed. The rack supports EtherNet/IP (via 1797-AENTR), DeviceNet (via 1797-DNYI), and PROFIBUS DP (via 1797-PFBR) — all fully compatible with the replacement module.
Q: Is the replacement unit ATEX/IECEx certified?
A: Each unit supplied by TOPNLMS is sourced to match the original Rockwell Automation certification scope. Please confirm your site’s specific zone classification and certification body requirements (ATEX, IECEx, FM, CSA) when placing your order so we can verify documentation availability.
Q: How much physical space does the module require?
A: The 1797-PS2E2 occupies one slot on the 1797 FLEX Ex backplane. No additional DIN rail space or control cabinet modifications are required for a direct replacement. Ensure the adjacent slot clearance meets Rockwell’s thermal derating guidelines if the rack is fully populated.
Q: What if my existing backplane is also damaged?
A: TOPNLMS stocks the 1797-BIC backplane interconnect cable and can advise on 1797-series backplane availability. Contact our team at [email protected] with your rack configuration for a complete BOM assessment.
Every 1797-PS2E2 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of shipment. Our pre-shipment inspection process includes functional power-on testing, output voltage verification, and visual inspection for physical damage or counterfeit indicators. Units that do not pass inspection are quarantined and never shipped.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund within the warranty period. Our after-sales response target is 24 hours for initial acknowledgment and 72 hours for resolution proposal. Warranty claims are processed via email at [email protected] with photographic evidence of the defect and the original order reference.
For procurement teams requiring documentation, we can provide a test report, packing list, and commercial invoice with each shipment. Lead time for standard stock items is 1–3 business days ex-Xiamen. Emergency orders with same-day dispatch are available upon request — contact us directly at +86 18359293191 to confirm stock availability before placing a time-critical order.
We understand that unplanned downtime in a hazardous-area process plant carries significant operational and safety consequences. Our inventory management and logistics processes are structured to support the fastest possible turnaround for emergency replacement orders, with tracking provided from dispatch to delivery.
Click Quote This Model and the Part Number field will auto-fill with 1797-PS2E2.