Allen-Bradley 1794-OB16 Ruggedized Output Module
1794-OB16Allen-Bradley 1794-OB16 Flex I/O 16-point 24VDC sourcing digital output module. Rugged, reliable, in-stock. 12-month warranty. Fast global shipping from TOPNLMS.
Request availability, condition, lead time and export shipping details for 1794-OF4I.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Allen-Bradley 1794-OF4I is a 4-channel isolated analog output module designed for the FLEX I/O platform — one of Rockwell Automation’s most widely deployed distributed I/O architectures in process and discrete manufacturing environments. As facilities transition away from aging control infrastructure, the 1794-OF4I remains a critical component in retrofit projects where engineers must maintain backward compatibility with existing wiring, terminal blocks, and PLC program logic while modernizing the broader control system.
Whether you are replacing a failed unit in a running production line, upgrading from an earlier FLEX I/O revision, or migrating an entire control cabinet from a legacy ControlLogix or SLC 500 platform, the 1794-OF4I provides a direct, drop-in solution that minimizes engineering rework and commissioning time. Each channel delivers isolated 4–20 mA or 0–10 V DC analog output signals, making it fully compatible with field instruments such as control valves, variable frequency drives, and positioners already wired to the existing terminal base assembly.
| Parameter | 1794-OF4I (This Unit) | Legacy / Predecessor Models |
|---|---|---|
| Output Channels | 4 isolated analog outputs | 1794-OF4 (non-isolated, 4-ch) |
| Signal Range | 4–20 mA / 0–10 V DC (per channel) | Same range; isolation architecture differs |
| Terminal Base | 1794-TB3, 1794-TB3S, 1794-TB32 compatible | Same terminal base family — no rewiring required |
| Communication | FLEX I/O backplane (DeviceNet, ControlNet, EtherNet/IP via adapter) | Same adapter compatibility: 1794-ADN, 1794-ACN15, 1794-AENT |
| Power Supply | 24 V DC via backplane from 1794-PS13 or equivalent | Same power architecture — no supply changes needed |
| Installation Space | Standard FLEX I/O single-slot footprint | Direct slot replacement — no DIN rail modification |
| PLC Compatibility | ControlLogix, CompactLogix, SLC 500 (via adapter) | Same controller families supported |
| Firmware / Config | Configured via RSLogix 5000 / Studio 5000 or RSLogix 500 | Existing I/O tree and tag database reusable |
| Warranty | 12 Months from shipment date | — |
A successful 1794-OF4I migration rarely involves a single module swap. In practice, engineers upgrading from a discontinued or end-of-life FLEX I/O node will also evaluate adjacent components within the same control cabinet or remote I/O drop. The 1794-AENT EtherNet/IP adapter is the most common communication upgrade pairing — replacing older 1794-ADN DeviceNet adapters to bring the I/O node onto a modern Ethernet backbone without changing the physical I/O modules or field wiring. Alongside the adapter, the 1794-TB3S terminal base provides spring-clamp termination that simplifies field wiring during hot-swap maintenance windows.
For sites running mixed analog and digital I/O in the same FLEX I/O rack, the 1794-IF4I isolated analog input module is frequently ordered alongside the 1794-OF4I to complete a balanced input/output node — particularly in PID loop applications controlling temperature, pressure, or flow. Where the existing 1794-PS13 power supply is aging or undersized for an expanded I/O configuration, replacement or supplemental power modules are evaluated as part of the same procurement.
In ControlLogix-based architectures, the 1794-OF4I node is typically managed through a 1756-EN2T EtherNet/IP communication module in the main chassis, with the FLEX I/O adapter appearing as a remote device on the same network segment. Engineers migrating from SLC 500 platforms often retain the FLEX I/O field wiring entirely while replacing only the controller and communication adapter — a strategy that protects the capital investment in field instrumentation and terminal wiring. For sites where the legacy 1794-ACN15 ControlNet adapter is still in service, the 1794-OF4I is fully compatible and can be retained in the existing ControlNet topology during a phased migration to EtherNet/IP.
Where signal isolation between the PLC analog output and field devices is a concern — particularly in environments with ground loops or high electrical noise — a signal isolator or loop-powered isolator installed between the 1794-OF4I output terminal and the field instrument provides an additional layer of protection without requiring changes to the module configuration or PLC program. This is a common addition in chemical processing, oil and gas, and heavy industrial retrofit projects.
Q: Can I replace a 1794-OF4 (non-isolated) with the 1794-OF4I without rewiring?
A: Yes. Both modules use the same FLEX I/O terminal base footprint. The field wiring connections at the terminal base remain unchanged. The primary difference is channel-to-channel isolation on the OF4I, which improves noise immunity. No PLC program changes are required — the I/O module tag structure is identical.
Q: Will my existing RSLogix 5000 / Studio 5000 program work without modification?
A: In most cases, yes. The 1794-OF4I uses the same module definition and output data structure as the non-isolated variant. If your program was built with the correct module catalog number, simply updating the I/O tree entry to 1794-OF4I and downloading the updated configuration is sufficient. Verify the output scaling parameters in your AO instruction blocks match the new module’s resolution specification.
Q: What communication adapters are compatible?
A: The 1794-OF4I is compatible with the full range of FLEX I/O adapters, including the 1794-AENT (EtherNet/IP), 1794-ACN15 (ControlNet), and 1794-ADN (DeviceNet). The adapter selection is independent of the I/O module — you can upgrade the adapter without changing the 1794-OF4I module or field wiring.
Q: Is the module compatible with 24 V DC field loops?
A: Yes. Each isolated output channel supports loop-powered 4–20 mA field devices. The module draws backplane power from the 1794-PS13 or equivalent FLEX I/O power supply. Ensure the power supply capacity is sufficient for the total I/O node current draw when adding modules to an existing rack.
Q: How do I handle physical space constraints in an existing control cabinet?
A: The 1794-OF4I occupies a single FLEX I/O slot on the DIN rail-mounted backplane. No additional mounting space is required compared to the module it replaces. If you are expanding the I/O node by adding modules, verify the backplane segment capacity and power supply rating before adding slots.
Every 1794-OF4I unit shipped from TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each module undergoes functional verification including power-on testing and output channel continuity checks. Units are packaged in anti-static protective packaging with appropriate cushioning for international freight.
In the event of a confirmed defect within the warranty period, TOPNLMS provides replacement support with priority processing to minimize impact on your production schedule. Our technical team is available to assist with installation verification, configuration questions, and compatibility confirmation before and after purchase. We maintain stock of the 1794-OF4I and related FLEX I/O components to support urgent replacement requirements with fast dispatch from our Xiamen warehouse.
For volume procurement, project-based orders, or scheduled maintenance stock programs, contact our sales team directly to discuss lead times, pricing, and documentation requirements including test reports and certificates of conformance.
Click Quote This Model and the Part Number field will auto-fill with 1794-OF4I.