Language English USD Currency
Call WhatsApp RFQ
Allen-Bradley Industrial Automation Part

Allen-Bradley 1756-CN2R Ruggedized ControlNet Redundant Module

Request availability, condition, lead time and export shipping details for 1756-CN2R.

Allen-Bradley

1756-CN2R

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part Number1756-CN2R
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesControlLogix
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Allen-Bradley 1756-CN2R Ruggedized ControlNet Redundant Module: Industrial Resilience for Harsh Environments

The Allen-Bradley 1756-CN2R is a ControlNet redundant communication module engineered for the ControlLogix 1756 platform — one of the most trusted programmable automation controller (PAC) architectures deployed across global heavy industry. Designed to sustain uninterrupted network communication in environments characterized by extreme temperature cycling, high-frequency mechanical vibration, pervasive electromagnetic interference (EMI), airborne particulate contamination, and elevated humidity, the 1756-CN2R delivers the network-layer redundancy that mission-critical control systems demand.

In continuous production environments — oil and gas processing trains, mineral extraction and beneficiation circuits, high-voltage power distribution substations, municipal water treatment facilities, and primary metals smelting operations — a single point of communication failure can cascade into unplanned downtime, safety incidents, and significant financial loss. The 1756-CN2R eliminates that single point of failure by providing dual-port ControlNet connectivity with automatic media redundancy switchover, ensuring that the ControlLogix backplane maintains deterministic, scheduled communication even when one network path is compromised.

Mounted directly into the 1756 chassis alongside the 1756-L series ControlLogix CPUs, the 1756-CN2R operates as a peer-level network interface, coordinating scheduled and unscheduled messaging across the ControlNet segment. It works in concert with 1756-CNB and 1756-CNBR bridge modules to extend network reach across large plant topologies, and integrates seamlessly with 1756-EN2T and 1756-EN2TR EtherNet/IP modules for hybrid network architectures that bridge legacy ControlNet infrastructure with modern Ethernet-based supervisory systems.

Rugged Specifications Table

Parameter Specification
Part Number / SKU 1756-CN2R
Brand Allen-Bradley (Rockwell Automation)
Series ControlLogix 1756
Module Type ControlNet Redundant Communication Module
Network Protocol ControlNet (IEC 61158 / ODVA)
Network Ports 2 × BNC (Coaxial), Redundant Media
Data Rate 5 Mbps
Backplane Interface 1756 ControlLogix Chassis Backplane
Operating Temperature 0 °C to +60 °C (32 °F to 140 °F)
Storage Temperature -40 °C to +85 °C
Relative Humidity 5% to 95% non-condensing
Vibration Resistance IEC 60068-2-6 compliant
EMI/EMC Protection IEC 61000-4 series; CE marked
Enclosure Rating IP20 (chassis-mounted); suitable for IP54+ control cabinet installation
Power Consumption ≤ 4.5 W (backplane powered)
Certifications UL, CE, C-Tick, ATEX (zone-rated cabinet deployment)
Country of Origin United States of America
Compatible Platforms ControlLogix, GuardLogix, SoftLogix (via 1756 chassis)
Application Sectors Oil & Gas, Mining, Power Generation, Water Treatment, Metals & Smelting
Warranty 12 Months — TOPNLMS Quality Guarantee

Comprehensive Protection Solutions

The 1756-CN2R does not operate in isolation — it is the communication backbone that ties together an entire ecosystem of ControlLogix automation components. In a typical high-availability control cabinet, the module shares the 1756 chassis with a 1756-L73 or 1756-L83E ControlLogix CPU, which executes the ladder logic and function block programs governing process safety interlocks. Redundant power is supplied through a pair of 1756-PA75 or 1756-PB75 power supply modules, ensuring that neither a mains fluctuation nor a DC bus sag interrupts backplane operation.

On the I/O side, 1756-IB16 digital input modules and 1756-OB16E digital output modules handle field-level discrete signals — limit switches, solenoid valves, motor contactors — while 1756-IF8 analog input modules process 4–20 mA signals from pressure transmitters, flow meters, and temperature sensors deployed across the process. For safety-rated applications, the 1756-CN2R coexists in the same chassis with 1734-IB8S and 1734-OB8S POINT Guard I/O safety modules, which are certified to SIL 2 / PLd under IEC 62061 and ISO 13849-1 respectively.

Communication beyond the ControlNet segment is handled by 1756-EN2TR dual-port EtherNet/IP modules, which provide Device Level Ring (DLR) topology support for resilient Ethernet connectivity to SCADA historians, MES platforms, and remote HMI panels. Where legacy serial devices remain in the field, 1756-MVI or 1756-DHRIO modules bridge older DH+ and Remote I/O networks into the modern ControlLogix architecture without requiring full field rewiring. The 1756-CN2R’s scheduled ControlNet messaging ensures that all of these subsystems exchange data with microsecond-level determinism — a requirement that standard Ethernet alone cannot guarantee in high-noise industrial environments.

Application in Critical Infrastructure

In upstream oil and gas wellhead automation, the 1756-CN2R anchors the communication layer of Emergency Shutdown (ESD) systems where SIL-rated response times are contractually mandated. The module’s redundant media architecture ensures that a cable strike, connector corrosion from H₂S exposure, or vibration-induced BNC connector fatigue does not sever the communication path between the safety PLC and field-mounted actuators. Operators in these environments rely on the ControlNet scheduled messaging model to guarantee that valve position feedback reaches the controller within every defined Requested Packet Interval (RPI), regardless of unscheduled traffic load.

In underground hard-rock mining operations, where blasting vibration, diesel particulate, and high ambient humidity create an exceptionally hostile electrical environment, the 1756-CN2R’s coaxial ControlNet medium provides superior noise immunity compared to unshielded twisted-pair Ethernet. The module has been deployed in ventilation control systems, conveyor drive coordination networks, and dewatering pump automation circuits where continuous uptime is non-negotiable.

Power generation facilities — including coal-fired, gas turbine, and hydroelectric plants — use the 1756-CN2R within turbine control and balance-of-plant (BOP) automation systems. The module’s deterministic scheduling ensures that turbine speed governor feedback loops, excitation control signals, and protection relay trip commands are communicated with the timing precision that grid-synchronization requirements demand. In water and wastewater treatment plants, the module coordinates communication between distributed pump stations, chemical dosing systems, and central SCADA platforms, supporting the continuous monitoring obligations imposed by environmental regulators.

Security & Quality FAQ

Q1: What warranty coverage does TOPNLMS provide for the 1756-CN2R?
Every 1756-CN2R shipped by TOPNLMS carries a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Each unit undergoes pre-shipment functional verification including backplane communication testing, ControlNet port integrity checks, and firmware version confirmation before dispatch. Warranty claims are processed directly through our technical team at [email protected].

Q2: How do you verify compatibility with my existing ControlLogix chassis and firmware revision?
The 1756-CN2R is compatible with all 1756 ControlLogix chassis sizes (4, 7, 10, 13, and 17 slots) and is supported across RSLogix 5000 and Studio 5000 Logix Designer firmware revisions from v13 onward. Our technical team can cross-reference your chassis catalog number, power supply rating, and controller firmware version prior to shipment to confirm drop-in compatibility. Provide your existing system configuration when contacting us and we will validate fit before invoicing.

Q3: Is the 1756-CN2R suitable for use in hazardous area classified zones?
The 1756-CN2R itself is rated for installation within IP54 or higher-rated control enclosures that are then deployed in Zone 2 / Division 2 classified areas, in accordance with ATEX and NEC 505 guidelines for purged and pressurized enclosures. For Zone 1 / Division 1 applications, the module must be housed in a certified Ex p (purged) or Ex d (flameproof) enclosure. Our team can advise on appropriate enclosure selection and installation practices for your specific hazardous area classification.

Q4: Can TOPNLMS support long-term spare parts supply and emergency replacement?
Yes. TOPNLMS maintains standing inventory of the 1756-CN2R and related ControlLogix 1756-series modules to support both planned maintenance schedules and emergency breakdown replacement scenarios. We offer expedited shipping to minimize plant downtime, and our stock is sourced from verified supply channels with full traceability documentation. For facilities operating under critical infrastructure obligations, we recommend establishing a framework spare parts agreement — contact [email protected] to discuss volume pricing and reserved stock arrangements.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with 1756-CN2R.