Allen-Bradley 1794-OB16 Ruggedized Output Module
1794-OB16Allen-Bradley 1794-OB16 Flex I/O 16-point 24VDC sourcing digital output module. Rugged, reliable, in-stock. 12-month warranty. Fast global shipping from TOPNLMS.
Request availability, condition, lead time and export shipping details for 1746-NO4V.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Allen-Bradley 1746-NO4V is a 4-channel voltage analog output module engineered for the SLC 500 programmable controller platform — one of the most widely deployed control architectures in global industrial automation. Designed to deliver precise, stable analog signal output in demanding production environments, the 1746-NO4V is a mission-critical component trusted across oil & gas, mining, power generation, water treatment, metallurgy, and continuous heavy manufacturing operations.
Where standard modules falter under thermal stress, electromagnetic interference, or mechanical vibration, the 1746-NO4V maintains signal integrity and output accuracy. Its robust construction and tight integration with the SLC 500 backplane make it the preferred choice for engineers who cannot afford control system downtime. Whether you are commissioning a new panel or replacing a failed module on a live production line, the 1746-NO4V delivers the performance and compatibility your application demands. Every unit shipped by TOPNLMS is pre-tested, inspected, and backed by a 12-month warranty — giving procurement teams and maintenance engineers the confidence to stock and deploy with zero hesitation.
| Parameter | Specification |
|---|---|
| SKU / Part Number | 1746-NO4V |
| Brand | Allen-Bradley (Rockwell Automation) |
| Series | SLC 500 |
| Module Type | Analog Output — Voltage |
| Number of Channels | 4 Channels |
| Output Signal Range | ±10 VDC / 0–10 VDC (software selectable per channel) |
| Resolution | 12-bit (1 in 4,095) |
| Output Load Impedance | ≥ 1 kΩ |
| Operating Temperature | 0°C to +60°C (32°F to 140°F) |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | 5% to 95% non-condensing |
| Vibration Resistance | Meets IEC 68-2-6 (sinusoidal vibration) |
| EMI/RFI Protection | Industrial EMC environments per CISPR 11 |
| Backplane Compatibility | SLC 500 fixed and modular chassis (1746 series) |
| Compatible Controllers | SLC 5/01, 5/02, 5/03, 5/04, 5/05 |
| Isolation | Optical isolation between field side and backplane |
| Protection Class | IP20 (panel-mounted, control cabinet installation) |
| Power Consumption | Supplied via SLC 500 backplane |
| Country of Origin | United States |
| Warranty | 12 Months — covers functional defects, output accuracy, and backplane interface |
| Application Sectors | Oil & Gas, Mining, Power, Water Treatment, Metallurgy, Heavy Manufacturing |
| Stock Status | In Stock — tested, inspected, and ready to ship |
The 1746-NO4V is a precision component within a broader SLC 500 control architecture that must remain reliable under continuous industrial stress. In a typical control cabinet deployment, it works in close coordination with the 1746-NI4 analog input module, which captures field sensor signals, while the 1746-NO4V converts controller commands into precise voltage outputs to drive actuators, positioners, and variable-speed drives.
For applications requiring mixed I/O density, the 1746-OB16 digital output module and 1746-IB16 digital input module are commonly installed in adjacent slots, sharing the same SLC 500 chassis and backplane power supply. The 1746-P4 power supply provides the regulated backplane voltage that sustains all modules under high-load conditions — a critical factor in high-temperature environments where power rail stability directly affects analog output accuracy.
Communication integrity is maintained through the 1747-SDN DeviceNet Scanner module or the 1747-KE DH-485 to RS-232C interface module, enabling the SLC 500 system to exchange real-time data with SCADA platforms, HMI panels, and distributed control nodes. In facilities running parallel Rockwell architectures, the 1746-NO4V integrates seamlessly alongside ControlLogix 1756-OF8 analog output modules in hybrid panel configurations where legacy SLC 500 racks coexist with newer Logix5000 systems.
For safety-critical zones, the 1746-NO4V is often paired with Allen-Bradley 440R GuardMaster safety relays and 1791DS CompactBlock Guard I/O safety modules to ensure that analog output signals are interlocked with machine safety states. Terminal block assemblies such as the 1492-CABLE series wiring systems provide clean, vibration-resistant field wiring connections that maintain signal fidelity even in high-vibration press, compressor, or pump applications.
In oil and gas upstream and midstream operations, the 1746-NO4V controls valve positioners on wellhead control panels and pipeline pressure regulation skids. Its optical isolation and EMI-hardened design protect signal integrity in environments saturated with variable-frequency drive harmonics and high-voltage switching transients from motor control centers. Ambient temperatures exceeding 50°C and persistent vibration from compressor trains present no obstacle to the module’s sustained output accuracy.
In mining and mineral processing, the module drives conveyor speed references, crusher feed rate controllers, and flotation cell level actuators. Continuous 24/7 operation in dusty, high-vibration underground or open-pit environments demands the kind of thermal stability and backplane robustness that the SLC 500 platform — and the 1746-NO4V specifically — is engineered to deliver. Maintenance teams in remote mine sites rely on the module’s proven field reliability and TOPNLMS’s in-stock availability to minimize unplanned downtime.
In power generation and substation automation, the 1746-NO4V provides precise analog setpoints to excitation systems, turbine governor controllers, and cooling system actuators. Its 12-bit resolution ensures fine-grained control authority that coarser output modules cannot match, reducing process variability and improving generation efficiency. The module’s optical isolation is particularly valuable in substation environments where ground potential differences and high-voltage transients are constant threats to signal integrity.
In water and wastewater treatment facilities, the module manages chemical dosing pump speed references, aeration blower output commands, and filter backwash valve positioning — all applications where analog output drift or module failure can trigger regulatory non-compliance events. The 1746-NO4V’s proven field reliability makes it a preferred spare-parts investment for plant maintenance teams managing aging SLC 500 infrastructure.
In metallurgical and steel production environments, where ambient temperatures routinely exceed 50°C and electromagnetic noise from arc furnaces and induction heaters is severe, the 1746-NO4V’s industrial-grade construction sustains output accuracy across the full operating temperature range, protecting process quality and reducing scrap rates. Its compatibility with the full SLC 500 chassis family means it can be deployed as a direct drop-in replacement without system reconfiguration or processor firmware changes.
Q1: What does the 12-month warranty cover for the 1746-NO4V?
Every 1746-NO4V shipped by TOPNLMS carries a 12-month warranty covering functional defects, analog output accuracy within published specifications, and backplane interface integrity. If the module fails to perform within its rated parameters during the warranty period, we provide replacement or full technical support at no additional cost. Warranty claims are processed promptly with documented test records available upon request.
Q2: How is each unit tested before shipment?
All 1746-NO4V modules undergo pre-shipment functional verification including backplane communication handshake testing, per-channel analog output accuracy measurement across the full ±10 VDC range, and visual inspection for connector integrity and board condition. Modules that do not meet Allen-Bradley published specifications are quarantined and not shipped. Test records are retained and can be provided with the shipment upon request.
Q3: Is the 1746-NO4V compatible with all SLC 500 chassis and processor variants?
Yes. The 1746-NO4V is compatible with all standard SLC 500 modular chassis (4-slot, 7-slot, 10-slot, and 13-slot configurations) and operates with all SLC 500 processor variants including the SLC 5/01, 5/02, 5/03, 5/04, and 5/05. It is also backward-compatible with older SLC 500 fixed controller systems that support 1746-series I/O expansion. No firmware upgrade is required for standard deployment.
Q4: Can TOPNLMS support long-term supply and emergency replacement needs?
Yes. TOPNLMS maintains dedicated inventory of Allen-Bradley SLC 500 series modules to support both planned maintenance schedules and emergency breakdown replacements. For critical infrastructure operators managing aging SLC 500 systems, we offer priority stock reservation and expedited shipping to minimize unplanned downtime. Contact our technical team to discuss long-term supply agreements, consignment stock arrangements, or cross-reference support for obsolete part numbers.
Click Quote This Model and the Part Number field will auto-fill with 1746-NO4V.