Language English USD Currency
Call WhatsApp RFQ
ABB Industrial Automation Part

ABB CM574-RS 1SAP170400R0001 Original Industrial Spare AC500

Request availability, condition, lead time and export shipping details for CM574-RS 1SAP170400R0001.

ABB

CM574-RS 1SAP170400R0001

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

BrandABB
Part NumberCM574-RS 1SAP170400R0001
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesAC500
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

ABB CM574-RS 1SAP170400R0001 Original Industrial Spare AC500: System Stability and Industrial Spare Parts Maintenance Value

The ABB CM574-RS (catalog number 1SAP170400R0001) is an original RS-485 serial communication module engineered specifically for the ABB AC500 series programmable logic controller platform. In industrial environments where continuous uptime is non-negotiable — from automotive assembly lines and water treatment facilities to chemical processing plants and power distribution substations — the CM574-RS serves as a critical communication backbone, enabling reliable serial data exchange between the AC500 CPU and field devices such as drives, sensors, HMIs, and third-party controllers.

Sourced directly from ABB’s authorized supply chain, this module carries the full original firmware, hardware revision, and factory calibration. It is not a compatible substitute or aftermarket replica — it is the genuine OEM component, ensuring seamless plug-and-play integration into existing AC500 control cabinets without the risk of firmware mismatch, communication timing errors, or warranty voidance on the host PLC system.

Critical Technical Specs

Parameter Specification
Part Number CM574-RS
Catalog Number 1SAP170400R0001
Brand / Manufacturer ABB (Germany)
Compatible PLC Series ABB AC500 (PM571, PM572, PM573, PM581, PM582, PM583, PM591, PM592)
Communication Interface RS-485 Serial (2-wire and 4-wire modes)
Supported Protocols Modbus RTU, Modbus ASCII, free serial communication
Baud Rate Up to 115,200 bps
Isolation Galvanically isolated RS-485 port
Supply Voltage Powered via AC500 CPU backplane (3.3 V / 5 V internal bus)
Operating Temperature -25°C to +60°C
Storage Temperature -40°C to +70°C
Humidity 5–95% RH, non-condensing
Protection Class IP20
Mounting Direct plug-in to AC500 CPU communication slot
Dimensions (W×H×D) Approx. 25 × 90 × 60 mm
Weight Approx. 200 g
Certifications CE, UL, cUL
Country of Origin Germany
Warranty 12 Months (TOPNLMS)

Preventive Maintenance Strategy

When a CM574-RS module is flagged for replacement during a scheduled shutdown or emergency repair, experienced maintenance engineers know that the communication module rarely fails in isolation. The RS-485 serial bus connects the AC500 CPU to a chain of downstream field devices, and any degradation in that chain — whether from aging wiring, loose terminal connections, or a failing power supply — can accelerate module wear or cause intermittent communication faults that are difficult to diagnose under production pressure.

A best-practice preventive maintenance inspection during a CM574-RS replacement should include a systematic check of the entire communication loop. Start with the AC500 CPU module (such as the PM573 or PM583) itself: verify firmware version, check for error LEDs, and confirm the CPU backplane connector is free of oxidation. Next, inspect the AC500 I/O expansion modules (e.g., DC532, DA501, AX521) connected on the same rack — loose backplane connectors are a common source of intermittent faults that are misattributed to the communication module.

The 24 VDC power supply module feeding the AC500 rack (such as the ABB CP502 or CP503) should be load-tested during the maintenance window. An under-voltage condition on the backplane bus is a leading cause of communication module resets and CRC errors on the RS-485 line. While the cabinet is open, inspect the terminal blocks and RS-485 wiring harness — check for broken shielding, improper termination resistors (120 Ω at each end of the bus), and correct polarity on the A/B data lines.

If the AC500 system communicates with variable frequency drives or servo controllers via Modbus RTU, this is also the right moment to verify the drive communication cards (e.g., FENA-21 Ethernet adapter or FDNA-01 DeviceNet adapter on ABB ACS drives) are firmly seated and their firmware is current. For systems using signal isolators between the CM574-RS and long-distance RS-485 runs, inspect the isolator modules for thermal stress or input/output voltage drift.

Facilities running mixed-protocol environments should also audit the gateway or protocol converter modules that bridge the RS-485 Modbus network to Profibus, PROFINET, or EtherNet/IP segments. A CM574-RS replacement is an ideal trigger point to verify end-to-end communication integrity across the entire fieldbus topology. Finally, check the HMI panel (such as an ABB CP600 series operator panel) connected to the serial network — HMI firmware updates and communication parameter re-validation are often deferred and can be efficiently bundled into the same maintenance event.

Maintaining a small buffer stock of the CM574-RS alongside companion modules — including spare CPU modules, I/O cards, power supplies, and communication cables — is a proven strategy for reducing mean time to repair (MTTR) in AC500-based control systems. Industrial buyers managing multi-line facilities or remote installations particularly benefit from on-site spare inventory, as lead times for original ABB modules can extend during peak demand periods.

Strategic Replacement Solutions

The CM574-RS 1SAP170400R0001 is the direct OEM replacement for aging or failed RS-485 communication modules in AC500 installations. Unlike third-party compatible modules that may require parameter reconfiguration, firmware re-flashing, or custom wiring adapters, the genuine CM574-RS installs directly into the existing CPU communication slot with zero hardware modification. The module retains all original Modbus RTU/ASCII configuration stored in the CPU project, meaning the replacement can be completed in minutes rather than hours — a critical advantage when every minute of downtime carries production cost.

For facilities managing legacy AC500 systems originally commissioned 10–15 years ago, the CM574-RS provides a direct path to extending system life without a full PLC migration. Replacing worn communication modules on a proactive schedule — rather than waiting for in-service failure — eliminates the risk of unplanned shutdowns and preserves the original control logic, HMI screens, and operator training investment. This approach is significantly more cost-effective than a full system upgrade and maintains full compatibility with existing SCADA, DCS, or MES integration layers that rely on the Modbus RTU protocol.

Each unit shipped by TOPNLMS undergoes pre-shipment functional verification, including communication port continuity testing and visual inspection for physical damage. Units are shipped in anti-static packaging with original ABB labeling and documentation where available. A 12-month warranty covers manufacturing defects and functional failures under normal operating conditions.

Support FAQ

Q1: Is the CM574-RS 1SAP170400R0001 compatible with all AC500 CPU variants?
The CM574-RS is designed for the ABB AC500 platform and is compatible with CPU modules including the PM571, PM572, PM573, PM581, PM582, PM583, PM591, and PM592. It plugs directly into the dedicated communication module slot on the AC500 CPU. Always verify your specific CPU hardware revision against ABB’s compatibility matrix if you are running an early-generation AC500 system.

Q2: How does TOPNLMS verify the module before shipment?
Each CM574-RS unit undergoes a pre-shipment inspection that includes visual examination for physical damage, connector pin integrity check, and communication port continuity verification. Units are packaged in anti-static bags with protective foam inserts. A 12-month warranty is provided from the date of shipment, covering manufacturing defects and functional failures under normal operating conditions.

Q3: What is the recommended spare inventory strategy for AC500 communication modules?
For facilities with 3 or more AC500 PLCs, maintaining at least one CM574-RS spare on-site is recommended. For critical processes (continuous production, utilities, safety systems), a 1:5 spare ratio (one spare per five installed units) is a common industry benchmark. Pairing the CM574-RS spare with a backup CPU module and power supply ensures the fastest possible recovery from any single-point communication failure.

Q4: Can the CM574-RS replace a failed module without reprogramming the PLC?
Yes. The CM574-RS is a hardware module — all communication parameters (baud rate, parity, Modbus address mapping, protocol selection) are stored in the AC500 CPU project, not in the module itself. A direct swap of a failed CM574-RS with a new unit requires no PLC reprogramming. After physical installation, the CPU will automatically recognize the module and resume communication on the next power cycle or warm restart.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with CM574-RS 1SAP170400R0001.