ABB AI830 3BSE008518R1 Replacement for S800 I/O Series
AI830 3BSE008518R1ABB AI830 3BSE008518R1 S800 I/O RTD analog input module. Drop-in replacement & upgrade for AC800M DCS systems. 8-channel, 12-month warranty. Ships from stock.
Request availability, condition, lead time and export shipping details for AO810V2 3BSE038415R1.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The ABB AO810V2 (3BSE038415R1) is an 8-channel analog output module engineered for the AC800M controller platform and the broader Symphony Plus DCS ecosystem. For facilities running aging S800 I/O racks, discontinued PM810V2 or PM864A controllers, or first-generation AO810 modules, this unit provides a validated, drop-in upgrade path that preserves existing field wiring, cabinet footprint, and control logic — dramatically reducing the engineering effort and downtime risk associated with a full system overhaul.
Industrial plants operating legacy ABB Advant OCS, Master, or early AC800M configurations frequently encounter end-of-life supply constraints on original analog output hardware. The AO810V2 addresses this directly: it slots into the same S800 I/O station mechanical rail, retains the standard 24 VDC bus-powered architecture, and communicates natively over the PROFIBUS DP and ModuleBus protocols already present in your control cabinet. No gateway, no protocol converter, no re-engineering of the fieldbus segment.
| Parameter | Legacy AO810 (Original) | AO810V2 3BSE038415R1 (Replacement) |
|---|---|---|
| Part Number | 3BSE008522R1 (AO810) | 3BSE038415R1 (AO810V2) |
| Output Channels | 8 × Analog (4–20 mA / 0–10 V) | 8 × Analog (4–20 mA / 0–10 V) |
| Resolution | 12-bit | 13-bit (improved accuracy) |
| Bus Interface | ModuleBus / PROFIBUS DP | ModuleBus / PROFIBUS DP (fully compatible) |
| Power Supply | 24 VDC via S800 I/O bus | 24 VDC via S800 I/O bus (identical) |
| Mechanical Form Factor | S800 I/O rail mount | S800 I/O rail mount (direct fit) |
| Terminal Block | TB820V2 / TB830 | TB820V2 / TB830 (reuse existing) |
| Controller Compatibility | PM810V2, PM864A | PM810V2, PM864A, PM891, PM895 (expanded) |
| Software / Engineering Tool | Control Builder M (CBM) | Control Builder M (CBM) — same project file |
| Firmware Upgrade Required | N/A | None required for standard replacement |
| Installation Space | Standard S800 slot | Standard S800 slot (no cabinet modification) |
| Replacement Recommendation | Direct swap — reuse field wiring, terminal block, and existing CBM configuration | |
| Warranty | End-of-life / no support | 12-Month Warranty from TOPNLMS |
A successful migration from a legacy analog output stage to the AO810V2 rarely involves a single module in isolation. In practice, the upgrade is part of a broader S800 I/O station refresh or AC800M controller modernization. The following components are commonly addressed in the same project scope:
The TB820V2 termination unit is the most frequently reused component in an AO810V2 swap — field cables remain connected to the terminal block while the module itself is hot-swapped, eliminating the need to re-terminate any wiring. Where the existing TB820V2 shows signs of contact wear or corrosion, replacement is straightforward and does not require loop shutdown if the station supports redundant I/O.
On the controller side, sites running the PM864A processor module alongside the original AO810 will find the AO810V2 fully recognized without any GSD file update. Plants that have already migrated to the PM891 or PM895 generation benefit from the AO810V2’s enhanced diagnostics, which surface channel-level fault data directly in Control Builder M without additional configuration.
Communication infrastructure is equally important. The CI854A PROFIBUS DP communication interface module, mounted in the same AC800M rack, handles the fieldbus segment that the AO810V2 participates in. If the CI854A is approaching its own end-of-life cycle, coordinating its replacement with the AO810V2 swap reduces the number of planned outage windows. Similarly, the CI801 ModuleBus optical interface is relevant for sites using fiber-optic I/O extension — the AO810V2 is fully compatible with this topology.
Power distribution within the S800 station is managed by the SD821 or SD822 power supply unit. Before commissioning the AO810V2, verifying that the station power budget accommodates the module’s 24 VDC draw is standard practice. In most cases, no power upgrade is required, but aging SD821 units with degraded output regulation should be flagged for concurrent replacement.
For sites integrating the upgraded analog output stage with a supervisory layer, the AC800M OPC server or 800xA System historian connection requires no reconfiguration — the AO810V2 presents the same data model as its predecessor. Plants running 800xA Operations with existing faceplate graphics for the AO810 will find those displays continue to function without modification.
Finally, where the control cabinet includes AI810 or AI830A analog input modules in adjacent slots, the AO810V2 coexists without any slot-ordering constraint. Mixed I/O stations combining analog inputs, analog outputs, and DI810 or DO810 digital I/O modules are a standard AC800M configuration and require no special addressing when the AO810V2 is introduced as a replacement unit.
Q: Can I reuse my existing field wiring when replacing AO810 with AO810V2?
Yes. The AO810V2 uses the same TB820V2 or TB830 termination unit. Field cables remain connected to the terminal block throughout the module swap. No re-termination is required.
Q: Do I need to modify my Control Builder M project?
In most cases, no. The AO810V2 is recognized by CBM using the same hardware type definition as the original AO810. Verify the module type in your hardware configuration tree and perform a download if prompted — this is typically a non-intrusive operation that does not interrupt running loops.
Q: Is the PROFIBUS DP address preserved after replacement?
Yes. The PROFIBUS node address is stored in the S800 I/O station’s bus modem, not in the individual module. Replacing the AO810V2 does not change the station address or require re-parameterization of the fieldbus segment.
Q: What is the physical installation procedure?
The AO810V2 mounts on the standard S800 I/O rail. Remove the existing module by releasing the locking lever, slide the AO810V2 into the slot, and engage the locking mechanism. The module self-identifies on the ModuleBus within seconds of power-up. No tools are required beyond standard ESD precautions.
Q: Are there any communication protocol differences I need to account for?
No protocol changes are required. The AO810V2 supports the same ModuleBus and PROFIBUS DP communication profiles as the original AO810. If your station uses the CI854A PROFIBUS interface, no GSD file update is needed for a like-for-like replacement.
Q: What if my cabinet space is constrained?
The AO810V2 occupies exactly the same physical slot as the original AO810. There is no change in module width, depth, or mounting pitch. No cabinet modification, DIN rail adjustment, or cable management rework is required.
Q: How do I verify the module is functioning correctly after installation?
After power-up, the AO810V2 LED status indicators should show green for module OK and channel active states. In Control Builder M, the module status object will report “OK” within the hardware configuration view. A loop check on each of the 8 output channels using a calibrated milliamp meter confirms signal integrity before returning the system to automatic control.
Every ABB AO810V2 3BSE038415R1 shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Our pre-shipment inspection process includes functional verification of all 8 analog output channels, bus communication handshake testing, and visual inspection for mechanical integrity. Units that do not pass our outgoing quality check are not shipped.
In the event of a warranty claim, TOPNLMS provides a replacement unit dispatch within 3 business days of fault confirmation. Our technical support team is available to assist with installation verification, loop commissioning questions, and compatibility confirmation for your specific AC800M or Symphony Plus configuration. We maintain stock of the AO810V2 and related S800 I/O components to support rapid response to unplanned outage scenarios.
For procurement teams, we provide a commercial invoice, packing list, and certificate of conformity with every shipment. Export documentation for international destinations is prepared in compliance with applicable trade regulations. Lead time for in-stock units is typically 3–7 business days to major industrial hubs in Asia, Europe, and the Americas.
To confirm availability, request a quotation, or discuss your specific migration requirements, contact our team directly:
📧 [email protected]
📞 +86 18359293191
Click Quote This Model and the Part Number field will auto-fill with AO810V2 3BSE038415R1.