ABB 07KP64 GJR5240600R0101 Replacement for AC31 PLC
07KP64 GJR5240600R0101ABB 07KP64 GJR5240600R0101 RS232 RCOM Communication Processor replacement for AC31 PLC. Drop-in upgrade, 12-month warranty, fast global shipping from stock.
Request availability, condition, lead time and export shipping details for 23TP22 1KGT013000R0001.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The ABB 23TP22 (part number 1KGT013000R0001) is a communication module designed for the ABB AC500 PLC platform — one of the most widely deployed programmable logic controller families in industrial process control, power distribution, and manufacturing automation. As legacy AC500 installations age and original modules reach end-of-life or become increasingly difficult to source, plant engineers and procurement teams face mounting pressure to find verified replacement units that maintain full backward compatibility without triggering costly system redesigns.
TOPNLMS maintains ready stock of the ABB 23TP22 1KGT013000R0001 sourced through established industrial supply channels. Each unit undergoes pre-shipment functional verification before dispatch from our Xiamen warehouse, ensuring that the module you receive is operationally ready for immediate installation into your existing AC500 rack or control cabinet.
Whether you are executing a like-for-like swap of a failed module, building a spare-parts buffer for a critical production line, or planning a phased migration from an older AC500 configuration to a modernized architecture, the 23TP22 provides the communication backbone your system requires without forcing changes to your existing wiring harness, terminal block layout, or PLC program logic.
| Parameter | Legacy / Outgoing Module | ABB 23TP22 (1KGT013000R0001) |
|---|---|---|
| Platform | ABB AC500 (earlier firmware revisions) | ABB AC500 — full series compatibility |
| Module Type | PLC Communication Module | PLC Communication Module |
| Part Number | Varies by revision (consult nameplate) | 1KGT013000R0001 |
| Communication Protocol | PROFIBUS DP / Modbus RTU / CS31 (application-dependent) | Compatible with AC500 supported fieldbus protocols |
| Rack / Backplane Interface | AC500 standard backplane connector | AC500 standard backplane connector — direct fit |
| Wiring Compatibility | Existing field wiring retained | No rewiring required for like-for-like replacement |
| Power Supply Requirement | 24 VDC via AC500 rack power module | 24 VDC via AC500 rack power module — unchanged |
| Programming Tool | Automation Builder / PS501 Control Builder | Automation Builder / PS501 Control Builder — no re-programming required for replacement |
| Physical Dimensions | Standard AC500 module form factor | Standard AC500 module form factor — no cabinet modification |
| Installation Space | Single slot on AC500 rack | Single slot on AC500 rack — identical footprint |
| Replacement Recommendation | End-of-life / discontinued revisions | Direct drop-in replacement; verify firmware version with ABB Automation Builder |
| Warranty | — | 12-Month Warranty from TOPNLMS |
A successful AC500 communication module replacement rarely involves a single component in isolation. In practice, field engineers replacing the 23TP22 often find that adjacent modules in the same rack or control cabinet require attention as part of the same maintenance window. TOPNLMS stocks a broad range of complementary AC500 platform components to support complete system restoration or phased modernization.
For installations where the communication module interfaces with distributed I/O over PROFIBUS DP, the AC500 TA521 terminal unit and associated I/O modules such as the DC532 digital input/output module or the AX522 analog I/O module are frequently replaced in the same service cycle. These modules share the same AC500 backplane architecture and can be swapped without modifying the existing DIN-rail mounting arrangement or terminal block wiring.
Where the 23TP22 is used to bridge the AC500 CPU — such as the PM573 or PM583 processor module — to a SCADA or DCS network via Modbus TCP or PROFINET, engineers should also verify the status of the AC500 communication processor and any CS31 bus couplers installed in the same rack. Aging CS31 bus modules are a common failure point in older AC500 installations and are best replaced proactively during the same outage window.
Control cabinet power integrity is equally critical during any module swap. The AC500 PS501 power supply module or equivalent 24 VDC rail-mount power supply should be inspected and replaced if output ripple or voltage sag is detected, as degraded power quality is a leading cause of communication module faults in the field. Signal isolation between the PLC rack and field instrumentation can be improved by adding DIN-rail signal isolators or Zener barriers where intrinsically safe circuits are involved.
For sites migrating from older ABB Advant or MOD 300 DCS architectures to the AC500 platform, the 23TP22 often serves as the communication gateway between legacy field devices and the new PLC backbone. In these migration projects, ABB AC500 programming cables (such as the TK501 USB programming cable) and the Automation Builder software license are essential procurement items alongside the module itself. HMI panels — including ABB CP600 series operator panels — are frequently upgraded in parallel to take advantage of the improved communication throughput that the modernized AC500 rack provides.
TOPNLMS can assist procurement teams in sourcing the full bill of materials for AC500 rack restoration or migration projects, including rack backplanes, CPU modules, I/O expansion modules, communication processors, and field termination assemblies, all from verified stock with consistent lead times.
Q: Can I replace the 23TP22 without modifying my existing field wiring?
A: Yes. The 23TP22 uses the standard AC500 backplane interface and the same terminal block pinout as previous communication module revisions. Field wiring connected to the terminal unit remains undisturbed during module replacement. Only the module itself is removed and reinserted into the rack slot.
Q: Do I need to re-download the PLC program after replacing the module?
A: For a like-for-like replacement of the same part number, the existing program stored in the AC500 CPU (PM5xx series) is retained and does not need to be re-downloaded. However, it is best practice to verify the communication configuration parameters in Automation Builder after module installation to confirm that fieldbus addresses and baud rate settings are correctly recognized by the new module.
Q: Is the 23TP22 compatible with both PROFIBUS DP and Modbus RTU networks?
A: The communication protocol supported by the 23TP22 is determined by the specific firmware and configuration loaded via Automation Builder. Consult the ABB AC500 system manual and the module’s firmware release notes to confirm protocol support for your specific network topology before installation.
Q: How much physical space does the replacement module require in the control cabinet?
A: The 23TP22 occupies a single standard slot on the AC500 rack. No additional DIN-rail space or cabinet modification is required. The module’s form factor is identical to other AC500 communication modules, ensuring a direct mechanical fit without spacer plates or bracket adapters.
Q: What should I check before commissioning the replacement module on a live PROFIBUS network?
A: Before powering up, verify that the PROFIBUS station address on the replacement module matches the address configured in the GSD file and the master PLC program. Confirm that the bus termination resistors at both ends of the PROFIBUS segment are correctly installed. After power-up, use the Automation Builder diagnostic tools to confirm that the module is recognized by the CPU and that all slave devices on the PROFIBUS segment are communicating without fault flags.
Q: Can this module be used in a migration from an older ABB Advant OCS or MOD 300 system?
A: The 23TP22 is an AC500-native module and is not a direct plug-in replacement for Advant or MOD 300 I/O modules. However, it can serve as the communication interface between the new AC500 PLC backbone and legacy field devices that support standard fieldbus protocols such as PROFIBUS DP or Modbus RTU, enabling a phased migration without requiring simultaneous replacement of all field instrumentation.
Every ABB 23TP22 (1KGT013000R0001) shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Our pre-shipment inspection process includes visual examination, connector integrity checks, and functional power-on verification to confirm that the module is free from manufacturing defects and transit damage before it leaves our Xiamen facility.
In the event that a module develops a fault within the warranty period under normal operating conditions, TOPNLMS will arrange a replacement unit or issue a credit at our discretion. Our after-sales response team is reachable by email at [email protected] and by phone at +86 18359293191 during business hours (GMT+8). We aim to respond to all warranty claims within one business day and to dispatch replacement units within three to five business days of claim approval, subject to stock availability.
For procurement teams managing critical infrastructure, we recommend requesting a certificate of conformance and pre-shipment test report at the time of order. These documents support your incoming inspection process and provide traceability for maintenance records and regulatory compliance purposes.
TOPNLMS ships globally from Xiamen, China, with standard export documentation including commercial invoice, packing list, and country of origin certificate. Express courier options (DHL, FedEx, UPS) are available for urgent replacement orders where minimizing system downtime is the primary procurement driver.
Click Quote This Model and the Part Number field will auto-fill with 23TP22 1KGT013000R0001.