Siemens 6AU1350-3AK41-1BE2 Ruggedized PROFIBUS Module
6AU1350-3AK41-1BE2Siemens 6AU1350-3AK41-1BE2 ISOPROFIBUS board for SINUMERIK 840D sl NCU. Rugged, EMI-resistant, 12-month warranty. In stock — fast global shipping.
Request availability, condition, lead time and export shipping details for 6XV1830-0EH10.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Siemens 6XV1830-0EH10 is a PROFIBUS FC (Fast Connect) Standard Cable designed for the SIMATIC NET industrial communication network. As a genuine original spare part, it plays a foundational role in maintaining reliable fieldbus communication between PLCs, distributed I/O stations, drives, and field devices across manufacturing, process, and utility automation environments. When a PROFIBUS segment goes down due to cable degradation, connector fatigue, or physical damage, the entire control loop dependent on that segment is at risk — making rapid, like-for-like replacement with the correct original cable a top priority for maintenance engineers.
In modern industrial facilities, PROFIBUS DP remains one of the most widely deployed fieldbus protocols, connecting Siemens S7-300, S7-400, and legacy S5 controllers to remote I/O racks, ET 200 distributed peripherals, frequency inverters, and intelligent field instruments. The 6XV1830-0EH10 is the standard-grade variant in the 6XV1830 series, offering a robust two-wire shielded construction optimized for the FC termination method — enabling field technicians to strip and terminate cable ends quickly without specialized tooling, reducing repair time during unplanned shutdowns.
| Parameter | Specification |
|---|---|
| Part Number | 6XV1830-0EH10 |
| Series | SIMATIC NET 6XV1830 |
| Brand | Siemens |
| Cable Type | PROFIBUS FC Standard Cable |
| Conductor Cross-Section | 2 × 0.64 mm² (AWG 22) |
| Characteristic Impedance | 135–165 Ω (3–20 MHz) |
| Capacitance per Unit Length | ≤ 30 nF/km |
| Loop Resistance | ≤ 110 Ω/km |
| Max. Transmission Rate | 12 Mbit/s |
| Max. Segment Length | Up to 1,000 m (at 9.6 kbit/s) |
| Operating Temperature | -20 °C to +60 °C (fixed installation) |
| Outer Diameter | Approx. 8.0 mm |
| Shielding | Braided copper shield |
| Jacket Material | PVC (violet, PROFIBUS standard color) |
| Termination Method | FC (Fast Connect) — tool-free stripping |
| Compatibility | Siemens S7-300, S7-400, ET 200M/S/SP, SINAMICS, MICROMASTER, DP/PA coupler |
| Country of Origin | Germany |
| Warranty | 12 Months |
Experienced maintenance teams know that a PROFIBUS cable fault rarely occurs in isolation. When inspecting or replacing the 6XV1830-0EH10, it is best practice to conduct a comprehensive audit of the entire PROFIBUS segment and the associated control cabinet. Begin by checking the PROFIBUS FC bus connectors (such as the 6ES7972-0BA52-0XA0) at each node — connector contacts corrode over time, and a degraded connector can introduce reflections that destabilize the entire segment even after the cable is replaced.
Next, inspect the PROFIBUS repeaters (e.g., 6ES7972-0AA02-0XA0) if the segment spans multiple zones or exceeds standard length limits. Repeaters are often overlooked during routine maintenance but are critical for signal integrity in large installations. While the cabinet is open, verify the condition of the IM 153-2 or IM 151-3 interface modules on ET 200M or ET 200S distributed I/O stations — these modules handle the PROFIBUS DP communication for entire I/O racks and should be part of any spare parts inventory alongside the cable itself.
For installations using SINAMICS G120 or MICROMASTER 440 drives connected via PROFIBUS, confirm that the drive’s PROFIBUS option board (CBP2 or equivalent) is seated correctly and that its address DIP switches match the configured node address in the PLC program. A loose option board can cause intermittent communication faults that mimic cable problems. Similarly, check the CP 342-5 or CP 443-5 communication processors in the S7-300/400 rack — these are the PROFIBUS master modules and are subject to firmware aging and connector wear.
During the same maintenance window, it is advisable to inspect the 24 VDC power supply modules (such as the SITOP PSU100S series) feeding the ET 200 stations and field devices on the PROFIBUS segment. Voltage sag or ripple from an aging power supply can cause DP slaves to drop off the bus intermittently, producing faults that are difficult to distinguish from cable or connector issues. Replacing a marginal power supply proactively is far less costly than an unplanned shutdown.
Finally, review the terminal blocks and shield clamps in the cable entry area of the control cabinet. Loose shield terminations are a leading cause of EMI-induced PROFIBUS errors in high-noise environments such as those with large VFDs or welding equipment nearby. Ensuring that the cable shield of the 6XV1830-0EH10 is properly clamped at the cabinet entry point — not just at the connector — is a simple step that significantly improves segment reliability and reduces nuisance faults.
The 6XV1830-0EH10 is the direct original replacement for aging PROFIBUS cabling in Siemens SIMATIC NET installations. Unlike generic fieldbus cables, it is manufactured to Siemens’ exact impedance, capacitance, and shielding specifications, ensuring full compatibility with the FC termination system and compliance with the PROFIBUS International standard EN 50170. This eliminates the risk of signal integrity issues that can arise when non-original cables with slightly different electrical characteristics are used in segments operating at higher baud rates (1.5 Mbit/s and above).
For facilities managing legacy S7-300 or S7-400 systems that are approaching end-of-life but cannot yet be migrated to TIA Portal-based S7-1500 platforms, maintaining a stock of original 6XV1830-0EH10 cable is a cost-effective strategy to extend system life by 5–10 years without hardware redesign. The cable’s FC termination method also reduces the skill requirement for field replacement — a technician familiar with the FC system can replace a damaged cable run in a fraction of the time required for traditional soldered or crimped PROFIBUS connections, directly reducing mean time to repair (MTTR) during unplanned outages.
Procurement teams should consider purchasing cable in standard reel lengths (50 m or 100 m) rather than cut-to-length segments to maintain flexibility for future segment extensions or rerouting. Storing reels in a climate-controlled spare parts room, away from UV exposure and chemical vapors, preserves the PVC jacket integrity and ensures the cable performs to specification when needed. Each reel supplied by TOPNLMS is tested prior to shipment and accompanied by documentation confirming its authenticity and electrical compliance.
Q1: Is the 6XV1830-0EH10 compatible with all PROFIBUS DP devices, or only Siemens equipment?
A: The 6XV1830-0EH10 meets the PROFIBUS International standard EN 50170 and is electrically compatible with any PROFIBUS DP device from any manufacturer. However, the FC (Fast Connect) termination method is specific to Siemens FC connectors. If you are using non-Siemens connectors with standard screw or IDC termination, the cable can still be used — the FC jacket stripping profile is simply not required.
Q2: What is the recommended inventory quantity for a facility with 10 PROFIBUS segments?
A: As a general guideline, maintain at least one spare reel (50 m) per 3–5 segments, plus a set of spare FC bus connectors for each segment. For critical production lines where downtime cost is high, consider holding a dedicated emergency reel at the machine level in addition to the central spare parts store.
Q3: How is the cable tested before shipment, and what does the 12-month warranty cover?
A: Each unit is inspected for physical integrity and verified against Siemens part number documentation before dispatch. The 12-month warranty covers manufacturing defects and electrical non-conformance under normal installation and operating conditions. It does not cover damage resulting from improper installation, mechanical abuse, or exposure to chemicals outside the cable’s rated resistance profile.
Q4: Can I use the 6XV1830-0EH10 in outdoor or underground installations?
A: The standard 6XV1830-0EH10 has a PVC jacket rated for fixed indoor installation. For outdoor, direct burial, or high-flex applications, Siemens offers alternative variants in the 6XV1830 series with PE jackets or trailing cable construction. Contact our technical team to confirm the correct variant for your installation environment before ordering.
Click Quote This Model and the Part Number field will auto-fill with 6XV1830-0EH10.