Language English USD Currency
Call WhatsApp RFQ
Bently Nevada Industrial Automation Part

Bently Nevada 330905-00-06-10-02-00 Replacement for 3300 XL

Request availability, condition, lead time and export shipping details for 330905-00-06-10-02-00.

Bently Nevada

330905-00-06-10-02-00

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part Number330905-00-06-10-02-00
CategorySensor
ConditionAvailability Check
Lead TimeRFQ Confirmation
Series3309
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Bently Nevada 330905-00-06-10-02-00 Replacement for 3300 XL: Smooth Transition & Legacy System Upgrade

When a rotating machinery protection system depends on continuous shaft displacement monitoring, an unplanned failure of the Bently Nevada 330905-00-06-10-02-00 proximity probe can trigger immediate production shutdowns. This 3300 XL Series 8mm eddy-current proximity probe is engineered for direct replacement of legacy and discontinued Bently Nevada probe assemblies, allowing maintenance teams to restore full vibration monitoring capability with minimal downtime and zero re-engineering of the existing measurement chain. Whether you are replacing a failed unit in a live plant or building MRO stock ahead of a planned outage, the 330905-00-06-10-02-00 delivers the same electrical and mechanical interface as the original, preserving your existing wiring, calibration records, and alarm setpoints.

The 330905-00-06-10-02-00 is a standard 8mm tip-diameter, 5-metre cable-length proximity probe within the Bently Nevada 3300 XL Series platform. It operates on the well-established eddy-current sensing principle, generating a linear DC voltage output proportional to the gap between the probe tip and the observed conductive target shaft. The probe interfaces directly with the Bently Nevada 330180 series proximitor/extension driver, maintaining the same −24 VDC bias voltage range and sensitivity specification of 7.87 V/mm (200 mV/mil) that field technicians and vibration analysts rely on for calibrated measurements. The probe body is rated for continuous operation from −35 °C to +177 °C, making it suitable for high-temperature bearing housings on steam turbines, compressors, and large rotating equipment.

Compatibility Comparison Table

Parameter Legacy / Replaced Model 330905-00-06-10-02-00 (This Unit)
Series Platform 3300 XL / 3300 NSv / 7200 Series (8mm) 3300 XL Series
Probe Tip Diameter 8 mm 8 mm — direct fit
Cable Length 5 m (varies by suffix) 5 m
Connector Type Standard BNC / coaxial Standard BNC / coaxial — no adapter needed
Sensitivity 7.87 V/mm (200 mV/mil) 7.87 V/mm (200 mV/mil)
Bias Voltage −24 VDC nominal −24 VDC nominal
Linear Range 0.25 – 2.25 mm (10 – 90 mil) 0.25 – 2.25 mm (10 – 90 mil)
Temperature Range −35 °C to +177 °C −35 °C to +177 °C
Target Material AISI 4140 / 4340 steel AISI 4140 / 4340 steel (compatible)
Proximitor Compatibility 330180 / 330100 / 330130 series 330180 / 330100 / 330130 series — confirmed
Installation Footprint Standard 3300 XL probe boss Identical — no machining required
Wiring Change Required None — drop-in replacement
Recalibration Required Gap re-set recommended; no full system recal
3500 Rack Compatibility 3500/42M, 3500/40M Fully compatible — no channel reconfiguration
Warranty OEM standard 12-Month Warranty (TOPNLMS)

Seamless Upgrade Solutions

A successful migration from a failed or end-of-life proximity probe assembly involves more than swapping the probe tip. In most 3300 XL installations, the probe works as part of a three-component measurement chain. The 330130-080-00-05 extension cable connects the probe to the proximitor driver, and any degradation in the cable’s coaxial shielding or connector integrity will introduce noise into the displacement signal even after the probe itself is replaced. It is therefore standard practice to inspect — and often replace — the extension cable simultaneously with the probe during a planned outage, treating the entire probe chain as a single replaceable assembly.

The proximitor driver, typically a Bently Nevada 330180-X1-05 proximitor or equivalent 3300 XL driver, conditions the raw probe signal into the calibrated −24 VDC output consumed by the monitoring rack. If the existing proximitor shows signs of drift, erratic gap voltage, or has accumulated significant operating hours, co-replacement with the 330905-00-06-10-02-00 probe is a cost-effective strategy that eliminates the risk of a second unplanned outage within the same monitoring loop. Both components share the same DIN-rail or panel-mount footprint, so cabinet space and wiring layout remain unchanged.

For facilities running a Bently Nevada 3500 Series rack-based machinery protection system — including the 3500/42M or 3500/40M vibration monitor modules — the 3300 XL probe chain output is accepted directly. No signal conditioning changes are required at the rack level when replacing the probe with this unit, preserving existing alarm setpoints, OK relay logic, and Modbus or FOUNDATION Fieldbus communication configurations already programmed in the 3500 system. This makes the 330905-00-06-10-02-00 an ideal first step in a phased modernization from a legacy 3300 rack to a full 3500 Series platform.

In older installations where the plant still operates a Bently Nevada 3300 Series rack (pre-XL generation), the 330905-00-06-10-02-00 probe remains electrically compatible, though the system integrator should verify the proximitor driver part number to confirm the matching sensitivity curve. Plants considering a full rack migration from 3300 to 3500 Series can use this probe replacement as the first step in a phased modernization, retaining the existing probe bosses and wiring infrastructure while upgrading the monitoring electronics over subsequent maintenance windows.

Where shaft displacement monitoring is complemented by process speed inputs, the Bently Nevada 330850 tachometer probe may be installed in an adjacent probe boss on the same bearing housing. These components share the same −24 VDC supply rail and coaxial wiring standard, simplifying multi-channel replacement logistics during a single planned shutdown. Similarly, if the application requires monitoring of axial position in addition to radial vibration, a 3300 XL 25mm proximity probe from the 330730 series can be added to the same measurement chain without changes to the power supply or signal conditioning architecture.

For control cabinets where DIN-rail space is constrained, the compact form factor of the 3300 XL proximitor allows the replacement assembly to fit within the original enclosure without panel modifications. If the plant’s condition monitoring data feeds into a Bently Nevada System 1 software platform or a third-party DCS historian via 4–20 mA or Modbus RTU, the output signal from the replacement probe chain is fully compatible with existing I/O mapping and tag configurations, eliminating the need for software re-engineering. Plants using signal isolators or barrier modules in intrinsically safe (IS) installations should verify that the existing IS barrier is rated for the 3300 XL probe’s capacitance and inductance parameters before completing the replacement.

Retrofit Guidance FAQ

Q: Do I need to re-wire the junction box when replacing the 330905-00-06-10-02-00?
No. The probe uses the same coaxial connector and cable standard as all 3300 XL series probes. The existing field wiring, junction box terminals, and conduit routing remain unchanged. Only the probe body and tip assembly are swapped.

Q: Is gap re-setting required after installation?
Yes. After mechanical installation, the air gap between the probe tip and the shaft must be set to the nominal value specified in the original system documentation — typically 1.0–1.5 mm for 8mm probes. This is performed with a digital voltmeter measuring the proximitor output voltage. No full system recalibration is required if the replacement probe is from the same 3300 XL series.

Q: Will this probe work with my existing 330180 proximitor driver?
Yes. The 330905-00-06-10-02-00 is designed to operate with the 330180 series proximitor drivers. The sensitivity, bias voltage, and linear range specifications are matched to the 330180 driver’s conditioning circuit, ensuring the replacement probe delivers the same calibrated output as the original.

Q: Can I use this probe as a replacement in a 3500/42M vibration monitor channel?
Yes. The 3500/42M accepts the standard 3300 XL probe chain. Existing channel configuration, OK limits, and alarm setpoints in the 3500 rack do not require modification. The replacement is transparent to the monitoring system.

Q: What if my existing extension cable is also damaged?
We recommend replacing the 330130 series extension cable simultaneously. A damaged coaxial shield in the extension cable will introduce noise and offset errors into the displacement measurement even with a new probe installed. Treating the probe chain as a complete assembly replacement is best practice for long-term reliability.

Q: Is this probe compatible with non-steel target shafts?
The 3300 XL 8mm probe is calibrated for AISI 4140/4340 steel targets. For non-standard target materials such as stainless steel, titanium, or Inconel, a material correction factor must be applied per Bently Nevada application guidelines. Contact our technical team for material-specific calibration support.

Q: What communication protocols does the 3500 rack support when using this probe?
The 3500 Series rack supports Modbus RTU, Modbus TCP, FOUNDATION Fieldbus, and Profibus DP depending on the communication gateway module installed. The probe replacement does not affect the rack’s communication configuration. Existing protocol mappings, tag names, and historian connections remain intact.

Warranty Assurance

Every Bently Nevada 330905-00-06-10-02-00 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to dispatch, each probe assembly undergoes functional verification including bias voltage output check, sensitivity confirmation, and connector integrity inspection. Units that do not meet the original Bently Nevada specification are quarantined and not offered for sale.

In the event of a warranty claim, TOPNLMS provides a direct replacement unit or full refund within the warranty period. Our after-sales response target is 24 hours for initial acknowledgment and 72 hours for resolution proposal. Replacement units are dispatched from our Xiamen warehouse with priority freight to minimize your system downtime.

For procurement teams requiring documentation, we can provide inspection reports, packing lists, and commercial invoices suitable for import customs clearance. Bulk orders for MRO stocking programs are supported with volume pricing and scheduled delivery agreements. All units are shipped with individual packaging and labeling to facilitate incoming inspection at your facility.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with 330905-00-06-10-02-00.